Ubiquiti 0810354023262 Скачать руководство пользователя страница 1

Managed PoE+ Gigabit Switch 

with SFP

Model: ES-16-150W

Содержание 0810354023262

Страница 1: ...Managed PoE Gigabit Switch with SFP Model ES 16 150W ...

Страница 2: ...2 Bracket Screws M4 Qty 8 Managed PoE Gigabit Switch with SFP Model ES 16 150 Mounting Screws 10 32 x 5 8 Qty 4 Cage Nuts 10 32 x 5 8 Qty 4 Rubber Feet Qty 4 Quick Start Guide TERMS OF USE All Ethernet cabling runs must use CAT5 or above It is the customer s responsibility to follow local country regulations including operation within legal frequency channels output power indoor cabling requiremen...

Страница 3: ...commend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti Networks For more details visit www ubnt com toughcable WARNING To reduce the risk of fire or electric shock do not expose the switch to rain or moisture Note Although the cabling can be located outdoors the EdgeSwitch itself should be hous...

Страница 4: ... Indicates Reset to Factory Defaults RJ45 1 16 PoE Off No PoE Amber IEEE 802 3af 802 3at Green 24V Passive Speed Link Act Off No Link Amber Link Established at 10 100 Mbps Flashing Indicates Activity Green Link Established at 1000 Mbps Flashing Indicates Activity SFP 1 2 Speed Link Act Off No Link Green Link Established at 1 Gbps Flashing Indicates Activity ...

Страница 5: ... System LED becomes blue after three seconds Continue to hold the Reset button for about 15 seconds until the System LED flashes blue for two seconds This indicates that the EdgeSwitch has reset to its factory defaults Power on Reset 1 Disconnect the Power Cord from the EdgeSwitch 2 While connecting the Power Cord to the EdgeSwitch hold the Reset button for about 15 seconds until the System LED fl...

Страница 6: ...ate 115200 Data bits 8 Parity NONE Stop bits 1 Flow control NONE Hardware Installation The EdgeSwitch can be placed on a horizontal surface mounted in a rack or mounted on a wall WARNING FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARD KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW Place the Rubber Feet on the bottom of the EdgeSwitch if you do not p...

Страница 7: ...ckets to the EdgeSwitch using the eight Bracket Screws positioning the brackets as shown below 2 Attach the EdgeSwitch to the rack using the four Mounting Screws If the rack has square slots then use the Cage Nuts with the Mounting Screws ...

Страница 8: ...ttach the Mount Brackets to the EdgeSwitch using the eight Bracket Screws positioning the brackets as shown below 2 Secure the EdgePower to the wall using the appropriate fasteners and anchors not included for the wall ...

Страница 9: ...Connecting Power 1 Connect the Power Cord to the Power port of the EdgeSwitch 2 Plug the Power Cord into a power outlet ...

Страница 10: ...ecting Ethernet 1 Connect an Ethernet cable from your computer or host system to any Ethernet port on the EdgeSwitch 2 Connect Ethernet cables from your devices to the other Ethernet ports on the EdgeSwitch ...

Страница 11: ...ble fiber module into the SFP port 1 0 0 0 M b p s S M S C 2 0 K M D D M T x 1 5 5 0 n m R x 1 3 1 0 n m 3 Connect the fiber optic cable to the fiber module Then connect the other end of the cable to another fiber device For information about compatible fiber SFP modules visit community ubnt com edgemax ...

Страница 12: ... an IP address and then check the DHCP server to see which IP address was assigned To log in follow these steps 1 Launch your web browser Type the appropriate IP address in the address field Press enter PC or return Mac 2 The login screen will appear Enter ubnt in the Username and Password fields Read the Ubiquiti License Agreement and check the box next to I agree to the terms of this License Agr...

Страница 13: ... 192 168 1 x subnet 3 Launch your web browser Type the appropriate IP address in the address field 192 168 1 2 is the default fallback IP address Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Read the Ubiquiti License Agreement and check the box next to I agree to the terms of this License Agreement to accept it Click Login ...

Страница 14: ... select DHCP on the IPv4 tab Click Submit Note If you change the IP settings then the session will be cut off and you will need to reconnect to the EdgeSwitch using the new IP address Customize additional settings as needed For more information refer to the EdgeSwitch documentation which is available at documentation ubnt com edgemax ...

Страница 15: ...igh Operating Temperature 5 to 40 C 23 to 104 F Operating Humidity 5 to 95 Noncondensing Shock and Vibration ETSI300 019 1 4 Standard LEDs Per Port RJ45 Data Ports SFP Data Ports PoE Speed Link Activity Speed Link Activity Networking Interfaces 16 10 100 1000 Mbps RJ45 Ports 2 1 Gbps SFP Ports Management Interface UART Console Out of Band Ethernet In Band PoE Interfaces PoE IEEE 802 3af at pins 1 ...

Страница 16: ...hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approve...

Страница 17: ...IV has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no original Ubiquiti MAC label or is missing any other original Ubiquiti label s or VII has not been received by Ubiquiti within 30 days of issuance of the RMA In addition the ...

Страница 18: ... FACILITIES UBIQUITI NETWORKS ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING In addition UBIQUITI NETWORKS does not warrant that the operation of the Products will be error free or that operation will be uninterrupted ...

Страница 19: ...the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 1...

Страница 20: ...environment and human health For more detailed information about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gem...

Страница 21: ...que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre anci...

Страница 22: ... la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS est conforme aux exigences essentielles et aux autres dispositions pertinentes des directives 2014 30 UE 2014 35 UE Deutsch German Hiermit erklärt UBIQUITI NETWORKS dass sich dieses UBIQUITI NETWORKS Gerät in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinien 2014 30 EU ...

Страница 23: ...nforme com os requisitos essenciais e outras disposições das Directivas 2014 30 UE 2014 35 UE Română Romanian Prin prezenta UBIQUITI NETWORKS declară că acest dispozitiv UBIQUITI NETWORKS este în conformitate cu cerințele esențiale și alte prevederi relevante ale Directivelor 2014 30 UE 2014 35 UE Slovensky Slovak Týmto UBIQUITI NETWORKS prehlasuje že toto UBIQUITI NETWORKS zariadenie je v súlade ...

Страница 24: ...e Ubiquiti U logo the Ubiquiti beam logo EdgeMAX EdgeOS EdgeSwitch and TOUGHCable are trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries All other trademarks are the property of their respective owners PH041116 w w w u b n t c o m ...