35
UAV-1001006-001
ECCN 7A994
Appendix C-2 GRT EFIS App Note
GRT EFIS with SafeFly 2020 GPS App Note
The GRT EFIS exchanges Setup, Control and GPS data with the echoUAT.
The echoUAT can also send ADS-B traffic and uplink data to GRT EFIS.
EchoUAT app settings:
If your transponder is controlled by the GRT EFIS:
Setup
Source
Control
Source
GPS
Source
Traffic
COM1
Rate
COM1
Data
COM1
Phy
COM1
Protocol
COM2
Rate
EFIS
EFIS
EFIS
COM1
MFD
COM2
38400
81O
RS232
TMAP
115200
If your transponder is panel mounted:
Setup
Source
Control
Source
GPS
Source
Traffic
COM1
Rate
COM1
Data
COM1
Phy
COM1
Protocol
COM2
Rate
EFIS
Transponder
Monitor
EFIS
COM1
MFD
COM2
38400
81O
RS232
TMAP
115200
GRT EFIS Settings:
General Setup:
Serial Port X* In:
Safe-Fly GPS and SPC
Serial Port X* Out:
Safe-Fly GPS ans SPC
Serial Port X* Rate:
115,200
SAVE
*Serial port “X” refers to the serial port on the EFIS that is wired to the “Serial Control In/Out”
of the Safe-Fly GPS module.
SPC Serial Port 1 Rate:
38400
SPC Serial Port 1 Output
EchoUAT/TMAP
SPC Serial Port 1 Input
EchoUAT/TMAP
Serial Port Y* In ADS-B
Serial Port Y* Rate 38,400 if connected to SafeFlySPC or 115,200 if connected to EFIS
SAVE
Serial port “Y” refers to the serial port used to receive ADS
-B data into the EFIS. For best
performance the ADS-B In (Pin 5) on the EchoUAT should be wired directly to a high speed port
on the EFIS and not connected to the serial combiner on the SafeFly GPS. If wiring through the
SafeFly we recommend a baud rate of 38,400. If wiring directly to the GRT EFIS we recommend
115,200.
Содержание echo
Страница 1: ...1 UAV 1001006 001 ECCN 7A994 Installation and Pilot s Guide ...
Страница 11: ...11 UAV 1001006 001 ECCN 7A994 ...
Страница 30: ...30 UAV 1001006 001 ECCN 7A994 Appendix A Interconnect Diagrams ...
Страница 31: ...31 UAV 1001006 001 ECCN 7A994 ...
Страница 32: ...32 UAV 1001006 001 ECCN 7A994 ...
Страница 37: ...37 UAV 1001006 001 ECCN 7A994 Example Wiring ...