15
UAV-1001006-001
ECCN 7A994
7.5 Connector Pin Assignments
Pin
Type
Physical
Default Config
Default
Protocol
1
Ground
-
-
-
2
Aircraft
Power
11-33V
-
-
3
COM1 TX
RS232 Out
RS485 A(-)
RS232 38400bps
81O
TMAP
4
COM1 RX
RS-232 In
RS485 B(+)
RS232 38400bps
81O
TMAP
5
COM2 TX
RS-232 Out
115200bps 81N
GDL 90
6
COM2 RX
RS-232 In
115200bps 81N
NMEA
Mating Connector: Molex 0436450600, Pins: 0462350001
Note: Use a 1A circuit breaker between the power source and echoUAT.
Optionally, a 3a gang circuit breaker can be used when combining
echoUAT and SkyFYX on the same circuit.
LED
SOLID
FLASHING
RED
FAULT
Transmit
GREEN
Powered
Receive
7.6 Cooling Requirements
echoUAT is designed to meet all applicable TSO requirements without
forced-air cooling.
Attention should, however, be given to the incorporation of cooling
provisions to limit the maximum operating temperature if the echoUAT is
installed in close proximity to other avionics. The reliability of equipment
operating in close proximity in an avionics bay can be degraded if adequate
cooling is not provided.