12
Model SH-PP Owner’s Manual
9.
STANDARD PART REPLACEMENT
PROCEDURES
9.1
Ionizer Wires
(See Figure 14)
1. Remove damaged wire from each spring.
2. Replace spring if damaged or missing.
3. Loop one end of new wire over bottom spring. Pull
top spring down with pliers and loop end of wire over
spring.
4. Release spring gently. Wire should now be taut and
centered.
NOTE: IF REPLACEMENT WIRES ARE NOT
AVAILABLE, REMOVE BROKEN WIRES AND/
OR SPRINGS FROM THE ASSEMBLY UNTIL
PARTS ARE AVAILABLE. OPERATION WITH
MISSING IONIZER WIRES WILL RESULT IN
REDUCED OPERATING EFFICIENCY.
9.2
Door Feed-Through Insulator
1. Turn toggle switch to the “off” position.
2. Open power pack access door.
3. Remove lead wire by removing both #10-32 hex
nuts.
4. Remove insulator retaining nut.
5. Open component access door and remove defective
insulator.
6. Remove long screw from insulator.
7. Clean RTV sealant from door surface.
8. Install replacement insulator, reversing the above
procedure, making sure to apply a thin coat of
sealant (RTV) to base insulator.
!
C A U T I O N
When the system is operating, 115 VAC is present in
this enclosure even with the toggle switch in the off
position.
9.3
Component Access Door Gasket
1. Remove existing door gasket making sure to remove
all contaminant residue.
2. Trim one edge of the new door gasket neatly and
evenly.
3. Measure and cut gasket to approximate length
required, allowing surplus for final trim.
4. Install the trimmed edge at the top center cabinet
door flange. Use a small mallet to tap the gasket on
the four-sided cabinet flange.
5. Check that the door gasket is firmly seated onto the
cabinet door flange. If the door gasket is not firmly
seated, the door gasket may not seal.
Содержание SMOG-HOG SH-PP
Страница 1: ...SMOG HOG MODEL SH PP Owner s Manual ...
Страница 4: ......
Страница 21: ...Model SH PP Owner s Manual 17 Figure 10 Installation of Ionizer Collector Cell Components ...
Страница 23: ......