Model
Number
Description
Total
BTU/Hr
Shipping Information
Lbs.
Kg
Cube
PS-6-26
Six Open Burners w/26" Oven
227,000
446
202
38.0
PS-6
Six Open Burners w/open storage
192,000
346
157
38.0
PS-12G-4-26
12" Griddle, Four Open Burners w/26" Oven
183,000
460
209
38.0
PS-12G-4
12" Griddle, Four Open Burners w/open storage
148,000
360
163
38.0
PS-24G-2-26
24" Griddle, Two Open Burners w/26" Oven
139,000
480
218
38.0
PS-24G-2
24" Griddle, Two Open Burners w/open storage
104,000
380
172
38.0
PS-36G-26
36" Griddle w/26" Oven
95,000
500
227
38.0
PS-36G
36" Griddle w/open storage
60,000
400
181
38.0
Pe
rf
or
m
er S S
er
ie
s 3
6" M
ed
iu
m
-D
ut
y R
an
ge
s
Item #:______________________________
Model: PS-(36)
Product Name: Performer S Series 36"
Medium-Duty Ranges
29
13 13/16
32
12 5/8
* RC
MOTOR
* ADD FOR
RC MOTOR
3 (76mm)
3/4" NPT
REAR GAS INLET
(152mm)
6
36
18
(457mm)
2 1/2
(64mm)
(321mm)
(813mm)
(351mm)
(1350mm)
(660mm)
(487mm)
(826mm)
(737mm)
(914mm)
26
32 1/2
19 3/16
53 5/32
3 7/16
(87mm)
5
(127mm)
3/4" NPT
REAR GAS INLET
6' POWER
SUPPLY CORD
(REAR, FOR RC OVEN ONLY)
OVEN
13-1/2 x 26-1/4 x 22
(343 x 667 x 559mm)
HEIGHT/WIDTH/DEPTH
Form #PS36 (06/06)
US Range reserves the right to change specifications without notice.
Printed in USA
Width
Depth
Height
Oven Interior
Combustible Wall Clearance
w/Legs
w/o Legs
Height
Depth
Width
Sides
Rear
36"
(914mm)
32"
(813mm)
38-1/2"
(978mm)
32-1/2"
(826mm)
13-1/2"
(343mm)
22"
(559mm)
26-1/4"
(667mm)
9"
(229mm)
6"
(152mm)
Burner Ratings (BTU/Hr)
Open
Griddle/Hot Top
Oven
32,000
20,000
35,000
Manifold Operating
Pressure
Entry Clearances
Natural
Propane
Crated
Uncrated*
4.5" WC
10.0" WC
46" (1168mm)
34" (864mm)
**With "RC" option: 37" (940mm)
Optional Convection Oven
(per oven)
115V
60Hz
1 Ø
5 Amps
6-ft. cord and plug included.
These appliances are intended for commercial use by profession-
ally trained personnel. It is the responsibility of the installer to
ensure that installation complies with national and local codes.