Alliance SL
Installation, Operating & Service Instructions
The Massachusetts Board of Plumbers and Gas Fitters has approved the Alliance SL™ Indirect-Fired Water Heater.
See the Massachusetts Board of Plumbers and Gas Fitters website,
http://license.reg.state.ma.us/pubLic/pl_
products/pb_pre_form.asp
for the latest Approval Code or ask your local Sales Representative.
The Commonwealth of Massachusetts requires this product to be installed by a Licensed Plumber or Gas Fitter.
Model
Performance Specifications
First Hour
(Gal/hr.)
Boiler Output
(6 GPM @ 200°F)
Boiler Water Continuous
Flow
Standby
Heat Loss
115°F
140°F
(BTU/hr.)
Flow Rate
(Gal/min.)
Head Loss
(ft. w.c.)
(°F/hr.)
AL27SL
295
225
150,000
6
7
0.78
AL35SL
300
230
150,000
6
7
0.72
AL50SL
320
250
150,000
6
7
0.56
AL70SL
340
270
150,000
6
7
0.45
AL70CSL
475
385
235,000
14
14
0.45
Additional Performance Specifications
Based on:
50
°
F inlet water temperature
200
°
F boiler supply to coil
Outputs may vary depending on boiler size, boiler water supply temperature, flow rate through
coil, and circumstances of installation and use.
2
Specifications & Ratings
Model
Storage
(gallons)
First Hour
Ratings
(gal/hr.)
Continuous
Draw
(gal/hr.)
Standby
Loss
(°F/hr.)
Heat Source
Friction Loss
(ft. w.c.)
Minimum Heat
Source Output
(Btu/hr.)
Minimum Heat
Source Flow
Rate (gpm)
AL27SL
26
192
170
1.0
18.0
106000
8
AL35SL
35
200
170
0.7
18.0
106000
8
AL50SL
50
225
180
0.6
19.0
117000
8
AL70SL
69
294
230
0.5
25.1
128000
8
AL70CSL
69
365
305
0.6
20.0
178000
14
Note:
1. First Hour Rating is the sum of the First Draw and Continuous Draw Ratings.
2. Ratings based on 77°F DHW temperature rise (135°F outlet temperature) and 180°F boiler supply temperature.
The ratings were obtained at the heat source (boiler) output rates and heat source flow rates shown. Other results
will be obtained under different conditions.
Rating Label Specifications