8
Light emitting diodes (LED)
LED’s from left to right:
Link
LED
Ethernet cable is OK when lit
Act.
LED:
Frequent flashing means data exchange
LED
– bi-color LED
Red flashes 2 times per second
– no connection to the ACS server
Green flashes once per second
– connection to the ACS server is OK
Reader’s annunciation
The access modes indicated with LED’s and buzzers of readers, connected via RS
485 bus (with U-Prox WRS485 interface convertor for Wiegand readers). Separate
adjustment for each elevator control panel available. The default annunciation is in
table below:
Operation mode
Reader annunciation
Normal mode
Red blinks once per second, no sound
PIN-code required
Red and green alters, no sound
Free pass (Fire mode)
Green and yellow alters, no sound
Blocking mode
Red and yellow alters, no sound
Alarm
Red lights continuously, no sound
Card enrollment
Green blinks once per second, no sound
Initiation
No lights, no sound
Download
Red lights continuously, no sound
PIN-code wait
Yellow blinks once per second, no sound
Access granted
Green lights continuously, no sound
Access denied
Red lights continuously, sounds continuously
Panel operation
Panels supplied unloaded with factory settings below in document. In this state, the
bi-color LED on the panel flashes red twice per second. To make the panel work in
access control system (ACS) you have to upload a network setting using the
"Configurator" software and USB port or use the automatic adjustment mode.
Panel goes to the
“Normal” mode after uploading the configuration.
To return to the factory settings use the command from the U-Prox software or with
the routine described in Service Maintenance section.