background image

Copyright © 20

20

 U-Line Corporation. All Rights Reserved. |  Publication Number 30379 |  

1

1

/20

20

 Rev. 

O

 

U-Line Corporation (U-Line) Limited Warranty

One Year Limited Warranty 

For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that 
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects 
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the 
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during 
normal business hours.  

Two Year Limited Warranty (5 Class Product) 

For two years from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that 
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects 
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the 
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during 
normal business hours. 

Available Second & Third Year Limited Warranty 

In addition to the standard one and two year warranties outlined above, U-Line offers a one year extension of the warranties from the date 
of purchase, free of charge. To take advantage of this extension, you must register your product with U-Line within 60 days from the date 
of purchase at u-line.com and provide proof of purchase. 

Five Year Sealed System Limited Warranty 

For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be 
defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line 
under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service 
provided during normal business hours. 

Terms 

These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten 
provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, 
maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and 
maintained in accordance with your product’s User Guide. 

The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any 
warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of 
these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal 
rights, and you may also have other rights which vary from state to state.   

Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of 

merchantability 

or any 

warranty 

fit for a particular purpose

 is limited to the duration of these warranties, and only extends to five years in duration for the parts 

described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty 
lasts, so the above limitations may not apply to you. 

The warranties only apply to the original purchaser and are non-transferable.

The second, third, and five year warranties cover products installed and used for normal residential or designated marine use only.

The warranties apply to units operated outside only if designed for outdoor use by model and serial number.

U-Line Commercial products are covered by the one year and 5 year limited warranties and are not eligible for the second and
third year limited warranties.

Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.

The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.

In-home instruction on how to use your product is not covered by these warranties.

Food, beverage, and medicine loss are not covered by these warranties.

If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip
charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.

Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only
and no coverage is provided for cosmetic defects.

Signal issues related to Wi-Fi connectivity are not covered by these warranties.

For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 

8900 N. 55

th

 

Street, Milwaukee, WI 53223 • u

-

line.com • onlineservice@u

-

line.com • +1.

414

.

354

.

0300

 

52

Содержание UHCP115

Страница 1: ...USER GUIDE SERVICE MANUAL 1 Class UHCP115 15 Clear Ice Machine with Pump...

Страница 2: ...racket General Installation Grille Installation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Ice Airflow and Produ...

Страница 3: ...lect products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty informat...

Страница 4: ...or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...mperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat genera...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...N Unit can NOT be installed behind a closed cabinet door If you would like to align the face of the unit with other adjacent cabinet doors you may need to alter the wall just behind the drain connecti...

Страница 9: ...ed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as show...

Страница 10: ...ct a licensed plumber Water Supply Connection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes before you install your unit Connect to the cold...

Страница 11: ...alve Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel b...

Страница 12: ...operty damage NOTICE Drain can NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loo...

Страница 13: ...o install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain pump NOTICE The maximum lift for the P60 drain pump is 10 feet...

Страница 14: ...ver holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water li...

Страница 15: ...ieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening...

Страница 16: ...unit the grille must be installed Removing the grille 1 Disconnect power to the unit 2 Slightly loosen three screws on bottom hinge 3 Remove two grille screws 4 Slide grille to the left and remove Ins...

Страница 17: ...adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance i...

Страница 18: ...from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is fi...

Страница 19: ...pulling outward exposing the gasket channel 3 Remove the 3 pieces of gasket channel filler and reinstall on the opposite end of door 4 Install gasket into channel beginning at one corner and pressing...

Страница 20: ...ine recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line When plugged in the unit will begin op...

Страница 21: ...r 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain so until user resets mode unit continues to operate Disable Sabbath Mode...

Страница 22: ...Control Operations sections for details and other options For more information about BrightShield visit www u line com For more information about Vyv Antimicrobial Light Technology visit www vyv tech...

Страница 23: ...bridge becomes thicker the tendency for the cubes to stay together as a slab increases A bridge thicker than 1 8 3 2 mm may cause cubes to overfill the ice bucket 32 ice cubes are formed on a 4 x 8 sl...

Страница 24: ...u line com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the unit will not perform as expected D...

Страница 25: ...r Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using ab...

Страница 26: ...dpipe into the water trough 6 Clean the Interior Bin as follows Dilute one packet of CLR cleaner into two quarts of water Using a sponge or cloth clean interior of ice bin tubing and door This cleaner...

Страница 27: ...aporator assembly ice mold Initially the water flow may not be uniform causing uneven sized cubes or water to spill into the ice storage bin This is a normal situation that will correct itself within...

Страница 28: ...nvironmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condens...

Страница 29: ...r must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or...

Страница 30: ...omponents with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing sound that may...

Страница 31: ...RELAY EMBRACO COMPRESSOR GREEN W YELLOW GROUND PINK LIGHT BLUE HOT WHITE 115V DARK BLUE 220 240V WHITE 115V DARK BLUE 220 240V PURPLE PUMP BLACK 115V BROWN 220 240V FAN 115 VOLT PLUG CONTROL BOARD BI...

Страница 32: ...nt of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial numb...

Страница 33: ...shes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may su...

Страница 34: ...rews 80 54230 00 22 Handle w logo 80 54214 00 23 Hi temp thermistor 80 54070 00 24 Hinges 2 w screws 80 54233 00 25 Hot gas valve and coil 80 54169 00 26 Ice scoop clr 80 54080 00 27 LED light strip a...

Страница 35: ...s will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U L...

Страница 36: ...Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near ro...

Страница 37: ...tic wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the...

Страница 38: ...ons a service mode menu and service menu selection explanations Verification of temperature and thermistor performance can be identified by directly viewing thermistor readings in the service mode Com...

Страница 39: ...level unit if needed Low Ice Production Dirty evaporator dirty condenser faulty bin thermistor Clean the evaporator using U Line cleaner clean the condenser coil if needed check bin thermistor reading...

Страница 40: ...does not or seems to not power on follow the flow chart below to help diagnose the issue Before beginning it is important to first verify the unit is not simply set to sabbath mode System Condition Su...

Страница 41: ...nents have been ruled out as being faulty but the unit continues to have operating issues it is most likely due to a configuration error Configuration errors can be cleared by restoring the unit to it...

Страница 42: ...ic grease REED SWITCH A reed switch is used to monitor door state When the door is closed magnetic force pulls the reed to its contact and closes the circuit which turns the light and display off When...

Страница 43: ...re Navigates through service menu LED activated with button activation 3 Down Button Decreases temperature Navigates through service menu LED activated with button activation 4 Light Button Activates...

Страница 44: ...he light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will allow the use of the contro...

Страница 45: ...to this model E5 Thermistor 1 shorted E6 Thermistor 2 shorted E7 Thermistor 3 shorted E8 Thermistor 4 shorted Does not apply to this model E9 Door 2 lower open P1 Pump Circuit open Does not apply to t...

Страница 46: ...s will show the number of minutes the compressor has run in the prior cycle or current cycle if the compressor was running when service mode was entered 24 ACTIVATE DEFROST HARVEST Turns on the hot ga...

Страница 47: ...conds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb button once 6 The display will blink and then will appear as the programmed d...

Страница 48: ...ator Fan Condenser Fan N A N A 2218R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218WC...

Страница 49: ...you encounter a dirty thermistor connection you should replace the thermistor and the thermistor harness This unit has two thermistors Thermistor one Ice Bin Located along the right hand side wall of...

Страница 50: ...on your meter Thermistor Resistance Data Type 2 Temp F Temp C Nominal Resistance OHMS 22 30 177000 13 25 130370 4 20 97070 5 15 72929 14 10 55330 23 5 42315 32 0 32650 41 5 25388 50 10 19900 59 15 157...

Страница 51: ...USER GUIDE Defrost 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Defrost These models have no defrost options 51...

Страница 52: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Отзывы: