USER GUIDE
u-line.com
Drain
If your U-Line unit did not come with a factory
installed drain pump you must use a gravity
style drain connection. For assistance in
determining if your unit has a pump please
contact U-Line. The floor drain must be large
enough to accommodate drainage from all
attached drains. Follow these guidelines when
installing drain lines to prevent water from
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may
result in personal injury or property damage
Failure to connect water supply or drain line
connections properly can result in personal injury
and property damage. Gravity drain connections
must be routed downward from the rest of the
unit at the rate of 1/4” per foot (1 cm per 50 cm).
Drain can NOT be located directly below the
unit. Unit has a solid base that will not allow the
unit to drain below itself.
There is a possibility that hose connections may
have loosened during shipment.
Verify all connections and fittings are free from
leaks.
This equipment is to be installed with adequate
backflow protection to comply with applicable
federal, state and local codes
A gravity drain may be used if:
Drain line has at least a 1” drop per 48” (approximately
2 cm drop per 100 cm) of run.
Drain line does not create traps and is vented per local
code.
1. Cut the pre-installed drain tube to length.
2. Connect to your local plumbing per the local code.
3. If necessary, insulate drain line to prevent
condensation.
DRAIN CONNECTION
GRAVITY DRAIN
NOTICE
Drain
CAUTION
!
CAUTION
!
CAUTION
!
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
With Trap and Vent
Proper Drain
12