background image

USER GUIDE

u-line.com

Drain

If your U-Line unit did not come with a factory 
installed drain pump you must use a gravity 
style drain connection. For assistance in 
determining if your unit has a pump please 
contact U-Line. The floor drain must be large 
enough to accommodate drainage from all 
attached drains. Follow these guidelines when 
installing drain lines to prevent water from 
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may 
result in personal injury or property damage

Failure to connect water supply or drain line 
connections properly can result in personal injury 
and property damage. Gravity drain connections 
must be routed downward from the rest of the 
unit at the rate of 1/4” per foot (1 cm per 50 cm). 

Drain can NOT be located directly below the 
unit. Unit has a solid base that will not allow the 
unit to drain below itself.

There is a possibility that hose connections may 
have loosened during shipment. 

Verify all connections and fittings are free from 
leaks.

This equipment is to be installed with adequate 
backflow protection to comply with applicable 
federal, state and local codes

A gravity drain may be used if:

Drain line has at least a 1” drop per 48” (approximately 
2 cm drop per 100 cm) of run.

Drain line does not create traps and is vented per local 
code.

1.  Cut the pre-installed drain tube to length.

2.  Connect to your local plumbing per the local code.

3.  If necessary, insulate drain line to prevent 

condensation.

DRAIN CONNECTION

GRAVITY DRAIN

NOTICE

Drain

CAUTION

!

CAUTION

!

CAUTION

!

Normal

Proper Drain

With Trap

Poor Drainage, Water Will Back Up

With Trap and Vent

Proper Drain

12

Содержание UHCP115-SS01A

Страница 1: ...USER GUIDE SERVICE MANUAL 1 Class UHCP115 15 Clear Ice Machine with Pump...

Страница 2: ...Tip Bracket General Installation Grille Installation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Ice Airflow and...

Страница 3: ...lect products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty informat...

Страница 4: ...or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...mperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat genera...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...N Unit can NOT be installed behind a closed cabinet door If you would like to align the face of the unit with other adjacent cabinet doors you may need to alter the wall just behind the drain connecti...

Страница 9: ...ed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as show...

Страница 10: ...nnection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes before you install your unit Connect to the cold water supply The water pressure shoul...

Страница 11: ...reates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break away filler featur...

Страница 12: ...he rate of 1 4 per foot 1 cm per 50 cm Drain can NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connec...

Страница 13: ...e ordered a pre installed U Line P60 drain pump If you need to install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain p...

Страница 14: ...models only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten...

Страница 15: ...n opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is...

Страница 16: ...unit the grille must be installed Removing the grille 1 Disconnect power to the unit 2 Slightly loosen three screws on bottom hinge 3 Remove two grille screws 4 Slide grille to the left and remove Ins...

Страница 17: ...adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance i...

Страница 18: ...from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is fi...

Страница 19: ...pulling outward exposing the gasket channel 3 Remove the 3 pieces of gasket channel filler and reinstall on the opposite end of door 4 Install gasket into channel beginning at one corner and pressing...

Страница 20: ...ine recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line When plugged in the unit will begin op...

Страница 21: ...l go dark and remain so until user resets mode unit continues to operate Disable Sabbath Mode Press and release Display and interior light return to normal operation Silent Mode ice production suspend...

Страница 22: ...bridge becomes thicker the tendency for the cubes to stay together as a slab increases A bridge thicker than 1 8 3 2 mm may cause cubes to overfill the ice bucket 32 ice cubes are formed on a 4 x 8 sl...

Страница 23: ...ATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or t...

Страница 24: ...abrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using abrasive pads such as ScotchBrite will c...

Страница 25: ...the ice machine off and allow any ice to melt off of the evaporator 2 Remove all ice from the storage bin 3 Remove evaporator cover 4 Remove the standpipe by lifting it up while using a slight back a...

Страница 26: ...e water flow may not be uniform causing uneven sized cubes or water to spill into the ice storage bin This is a normal situation that will correct itself within the first 24 hours of operation NOTICE...

Страница 27: ...nvironmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condens...

Страница 28: ...r must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or...

Страница 29: ...omponents with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing sound that may...

Страница 30: ...nt of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial numb...

Страница 31: ...shes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may su...

Страница 32: ...rews 80 54230 00 22 Handle w logo 80 54214 00 23 Hi temp thermistor 80 54070 00 24 Hinges 2 w screws 80 54233 00 25 Hot gas valve and coil 80 54169 00 26 Ice scoop clr 80 54080 00 27 LED light strip a...

Страница 33: ...s will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U L...

Страница 34: ...Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near ro...

Страница 35: ...tic wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the...

Страница 36: ...s some diagnostic tips and as always if additional help is required please contact the U Line Corp Customer Care Facility at 1 800 779 2547 for assistance NORMAL OPERATING SOUNDS All models incorporat...

Страница 37: ...level unit if needed Low Ice Production Dirty evaporator dirty condenser faulty bin thermistor Clean the evaporator using U Line cleaner clean the condenser coil if needed check bin thermistor reading...

Страница 38: ...low chart below to help diagnose the issue Before beginning it is important to first verify the unit is not simply set to sabbath mode Check Voltage At Wall Outlet Verify Voltage At Main Control Volta...

Страница 39: ...re Navigates through service menu LED activated with button activation 3 Down Button Decreases temperature Navigates through service menu LED activated with button activation 4 Light Button Activates...

Страница 40: ...he light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will allow the use of the contro...

Страница 41: ...to this model E5 Thermistor 1 shorted E6 Thermistor 2 shorted E7 Thermistor 3 shorted E8 Thermistor 4 shorted Does not apply to this model E9 Door 2 lower open P1 Pump Circuit open Does not apply to t...

Страница 42: ...s will show the number of minutes the compressor has run in the prior cycle or current cycle if the compressor was running when service mode was entered 24 ACTIVATE DEFROST HARVEST Turns on the hot ga...

Страница 43: ...conds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb button once 6 The display will blink and then will appear as the programmed d...

Страница 44: ...ator Fan Condenser Fan N A N A 2218R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218WC...

Страница 45: ...ain the operating temperature within that zone Thermistor two Evaporator Located on the evaporator It is used for defrost THERMISTOR FAILURE Zone Thermistor If the zone thermistor in the unit fails th...

Страница 46: ...USER GUIDE Defrost 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Defrost These models have no defrost options 46...

Страница 47: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Отзывы: