background image

USER GUIDE

u-line.com

Interior Adjustments

Wine Storage Options

WINE RACK BOTTLE POSITION

Specially designed horizontal wine racks properly position 
the bottles so the wine remains in contact with the cork, 
which ensures the cork does not become dry.

Racks are designed to accommodate typical 750ml wine 
bottles as follows:

UHWD524 24” Wine Captain Models

SLIDE AND SECURE STORAGE BIN ADJUSTMENT

Removal

1.  Empty and remove bin.

2.  Firmly grasp both sides of storage bin frame and lift 

front end slightly (about 1/4”) to center the pin in the 

slot.

3.  Pull frame towards you until all pins are clear of the 

slots. If only repositioning the frame, do not remove 

completely - go to “Storage Bin Installation” Step 2.

4.  Slightly tilt one side. Gently pull frame towards you to 

remove from unit.

Note: Take care when removing frame to avoid 
scratching interior of unit.

5.  Once removed, retract the slides.

Note: The slides on the frame have a thin coating 
which is used to block moisture and provide 
lubrication. Use care when handling

Installation

1.  Insert empty storage bin frame into unit with one side 

tilted slightly downward until back pin is between front 
and rear rail supports.

2.  Tilt frame back to horizontal and line up 2 back pins 

with rear rail support. Line up left side of frame with 
rear and front rail support. Continue inserting frame 
until both pins engage. The front will set down slightly 
and lock into place. Repeat on right side.

3.  Fully extend frame, position bin over frame and lower 

(rear first) into position. 

Slide and Secure Storage Bins

Glass inserts are designed so bottles and cans sit flat. The 

inserts may be removed when storing produce or other 

items. The ridges in the bottom facilitate air flow.

Clean the storage bins with soap and water. 

      

7 Bottles

Center 

the pin

Center 

the pins

Front Pin

Back Pin

26

Содержание UHBD524

Страница 1: ...USER GUIDE SERVICE MANUAL 5 Class UHBD524 24 Dual Zone Beverage Center...

Страница 2: ...Side Installation Anti Tip Bracket General Installation Integrated Panel Dimensions Integrated Panel Installation Grille Installation Door Swing Door Adjust Interior Adjustments Maintenance Cleaning...

Страница 3: ...available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty information are all avail...

Страница 4: ...or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...mperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat genera...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...an electrical connection in the rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS PRODUCT DIMENSIONS REAR FRONT TOP SIDE 4 102 mm 7 178 mm 24 610 mm 23 7 8 607 mm...

Страница 9: ...on Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintaine...

Страница 10: ...r a proper fit Also test to make sure the door opens and closes freely 3 Remove grille and place a mark on the floor at the front of the unit Also place a mark on the floor in the center of the unit 4...

Страница 11: ...n opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is...

Страница 12: ...hat all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed in the diagram below 2 Optional Stain o...

Страница 13: ...m to the underside of the counter to leave room for leveling adjustments A single prepared frame with insert must not weigh more than 20 lbs 10 kg Integrated Frame Preparation 1 Cut the main panel to...

Страница 14: ...sions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R 16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref Cutout for Frame Units Top Detail Insert Notch Top...

Страница 15: ...weigh more than 20 lbs 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed Appliance will need up t...

Страница 16: ...AT AND WITHOUT INTERFERENCE 2 3 4 MIN 70 mm MIN Integrated Frame 3 4 20 mm 23 1 2 595 mm 32 7 8 to 33 7 8 834 mm to 860 mm A minimum of 1 25 mm is required from the floor to the bottom of the extended...

Страница 17: ...it drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to ensure that all drilled holes are drilled to the correct depth in order...

Страница 18: ...e unit the grille must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two s...

Страница 19: ...itional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door clearance on hinge side to allow for...

Страница 20: ...en each pair of Torx head screws both the upper and lower hinge plates 3 Square and align door as necessary 4 Tighten Torx head screws on hinge 5 Reinstall gasket into the channel starting at the corn...

Страница 21: ...as turned off during installation simply press and the unit will immediately switch on To turn the unit off press If the temperature displayed is different than selected the unit is progressing toward...

Страница 22: ...ide Display Hold and press Display will turn off when door is closed Unit will continue to operate Repeat command to turn on display Adjust light color While holding press and release to scroll throug...

Страница 23: ...ontrol Operation Dual Zone Temperature Table Beverage Dual Zone Lower 33 45 Upper 38 65 Minimum Maximum 33 38 53 34 38 54 35 38 55 36 38 56 37 38 57 38 38 58 39 39 59 40 40 60 41 41 61 42 42 62 43 43...

Страница 24: ...ies U Line uses the following sizes Combinations of red and white bottles are used in Wine Captain Models and Beverage Centers NOTICE Restricting airflow may result in poor product performance product...

Страница 25: ...Note Take care when removing rack to avoid scratching interior of unit 5 Once removed retract the slides Note The slides on the rack have a thin coating which is used to block moisture and provide lu...

Страница 26: ...g frame to avoid scratching interior of unit 5 Once removed retract the slides Note The slides on the frame have a thin coating which is used to block moisture and provide lubrication Use care when ha...

Страница 27: ...ess steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated pan...

Страница 28: ...sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 A...

Страница 29: ...nvironmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condens...

Страница 30: ...n the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and milde...

Страница 31: ...ompressor makes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the un...

Страница 32: ...ng the testing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal tempera...

Страница 33: ...fan Condenser fan L T Zone temp L T Door switch R B Door switch L T Evap temp R B Zone temp R B Evap temp EVAPORATOR VALVE COMPRESSOR Yellow Programming W I F I A n t e n n a D i a g n o s t i c s V...

Страница 34: ...zed to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from t...

Страница 35: ...ing for warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update...

Страница 36: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Отзывы: