background image

USER GUIDE

u-line.com

Cutout & Product Dimensions

Cutout & Product Dimensions

PREPARE SITE

Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit 
does not require additional air space for top, sides, or   
rear. However, the front grille must NOT be obstructed, 
and clearance is required for an electrical connection in        
the rear.

CAUTION

!

Unit can NOT be installed behind a closed cabinet 
door.

CUTOUT DIMENSIONS

PRODUCT DIMENSIONS

REAR

 FRONT

 TOP

 

 SIDE

1 3⁄8”

(35 mm)

 

6 ft (183 cm)

Power Cord

11 ¾”

(222 mm)

 

23

 

5⁄8”

(600 mm)

 

3 ½”

(89 mm)

 

33 11⁄16”

(855 mm)

 

28”

(711 mm)

 

1 7⁄8”

(48 mm)

 

18 15⁄16”

(481 mm)

 

24 ¾”

(629 mm)

 

21 1⁄16”

(535 mm)

 

24 1/4”

(616 mm)

 

22 15⁄16”

(583 mm)

 

24 13⁄16”

(630 mm)

 

4“

 (102 mm)

17 1/2”

(445 mm)

 

4" 

(102 mm)

7" 

(178 mm)

24"

(610 mm)

23 

7/8

"

(607 mm)

34"

(864 mm)

Preferred location 

for electrical outlet 

is in adjacent 

cabinet.

5/8

"

(16 mm)

8

Содержание UCRE524

Страница 1: ...USER GUIDE SERVICE MANUAL Refrigerators UCRE524 24 Refrigerator...

Страница 2: ...Swing Door Adjust Interior Adjustments Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Airflow and Product Loading Service Troubleshooting...

Страница 3: ...lect products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty informat...

Страница 4: ...gular use Do not use sharp objects to expedite defrosting Do not service without consulting the R600a specifications section included in the User Guide Do not damage the refrigerant circuit Service mu...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are prese...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...ce is required for an electrical connection in the rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS PRODUCT DIMENSIONS REAR FRONT TOP SIDE 1 3 8 35 mm 6 ft 183 cm...

Страница 9: ...er line measure A to the left and right This line is the outer edge of each bracket C L Back wall Back of unit Front of unit Surrounding area Top view A A B 515 518 524 A 7 5 8 9 11 15 16 B 22 22 22 5...

Страница 10: ...eve a total unit rear height of 1 8 3 mm less than opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Read...

Страница 11: ...e unit the grille must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two s...

Страница 12: ...ng Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wa...

Страница 13: ...ess on the hinge system Alignment and Adjustment Procedure 1 On top and bottom sufaces of door slightly loosen hinge bracket screws 2 Square and align door as necessary 3 Tighten Torx head screws on h...

Страница 14: ...as turned off during installation simply press and the unit will immediately switch on To turn the unit off press If the temperature displayed is different than selected the unit is progressing toward...

Страница 15: ...lding press and release to scroll through lighting options Option Open Door Closed Door 00 White White 01 Blue Blue 02 White Blue Light will be set at full intensity when door is open and 50 intensity...

Страница 16: ...d sizes Not all bottles and cans will fit on every shelf and wine rack Larger diameter champagne and Magnum bottles only fit on wine racks when noted on the product specifications When determining cap...

Страница 17: ...ep 2 4 Slightly tilt one side Gently pull shelf towards you to remove from unit Note Take care when removing shelf to avoid scratching interior of unit 5 Once removed retract the slides Note The slide...

Страница 18: ...ned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible CLEAN INTERIOR COMPONENTS Use warm or hot water with dish soap to clean all remove...

Страница 19: ...by reversing above steps 1 4 Remove Wine Rack 1 Fully extend empty rack 2 Firmly grasp both sides of rack and lift front end of rack slightly about 1 4 to center the pin in the slot 3 Pull rack towar...

Страница 20: ...evaporator cover 4 Remove evaporator fan assembly from evaporator cover 5 Remove 4 rack supports by removing 4 screws on each one 6 Remove screws and spacers from evaporator and carefully pull evapora...

Страница 21: ...Apply firm pressure evenly across the length of the cover until it snaps into place Hinge Pin Bracket Remove Door Brackets and Hinge 1 Hold door to keep it from falling 2 Remove top hinge pin 3 Remove...

Страница 22: ...inner lining or damage the cooling unit DO NOT use any type of heater to defrost Using a heater to speed up defrosting can cause personal injury and damage to the inner lining NOTICE The drain pan wa...

Страница 23: ...nvironmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condens...

Страница 24: ...n the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and milde...

Страница 25: ...ompressor makes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the un...

Страница 26: ...ng the testing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal tempera...

Страница 27: ...T Evap fan R B Evap fan Condenser fan L T Zone temp L T Door switch R B Door switch L T Evap temp R B Zone temp R B Evap temp Compressor Open Programming W I F I A n t e n n a D i a g n o s t i c s V...

Страница 28: ...zed to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from t...

Страница 29: ...ing for warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update...

Страница 30: ...80 55486 00 13 EVAPORATOR FAN 80 54807 00 14 EVAPORATOR FAN COVER W SCREWS 80 54809 00 15 GASKET DOOR 80 54039 01 16 GRILLE 24 5 CLASS 80 55487 00 17 HINGE ASSEMBLY 80 55374 01 18 HI TEMP THERMISTOR 8...

Страница 31: ...rovide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform you when the parts o...

Страница 32: ...cian must observe all federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder t...

Страница 33: ...cuum pump and recovery equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the sys...

Страница 34: ...erant is left within the system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing...

Страница 35: ...Install a Schrader Type access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two...

Страница 36: ...erature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes war...

Страница 37: ...h are not hot or frozen Do not touch a bare circuit board unless you are wearing an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefu...

Страница 38: ...2547 for assistance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Des...

Страница 39: ...Mode OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry Check distribution of product in unit Thermistor failure OHM thermistor...

Страница 40: ...e Plunger Switch Replace Main Board Replace Fuse Replace Power Cord Alert Customer Of Power Failure Is the Plunger Switch Operating Properly Inspect Customer UI and Data Cable Connect Test Display Cyc...

Страница 41: ...r exit this mode hold the light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will allo...

Страница 42: ...igh temp alarm limit Model 55 only 1 THERMISTOR 1 ZONE This shows the pure thermistor reading with no offsets taken into account 2 THERMISTOR 2 EVAPORATOR This shows the pure thermistor reading with n...

Страница 43: ...of the specific unit See Model list table 22 LIGHT ALL LED SEGMENTS This will illuminate all the LEDs on the display to ensure they work properly 23 ACTIVATE DEFROST HARVEST Press and hold for 3 secon...

Страница 44: ...1A 38 HWC524 1A 39 HWC524 2A 40 HWC336 1A 41 HBD324 1A 42 HBD324 2A 43 HBD524 1A 44 HBD524 2A 45 HWD324 2A 46 HWD324 1A 47 HWD524 2A 48 HWD524 1A 49 HRF124 2A 50 HRF124 1A 51 HRI124 2A 52 HRI124 1A 5...

Страница 45: ...ht 2 Evap Fan Cond Fan 22 RE336 1A Compressor Top Left Valve Bot Right Valve Light 1 Light 2 Evap Fan Evap Fan 2 Cond Fan 23 RE515 1A Compressor Light 1 Light 2 Evap Fan Cond Fan 25 RE524 1A Compresso...

Страница 46: ...ain the operating temperature within that zone Thermistor two Evaporator Located on the evaporator It is used for defrost THERMISTOR FAILURE Zone Thermistor If the zone thermistor in the unit fails th...

Страница 47: ...hours of compressor runtime for 45 minutes If you have verified that the unit does not have an ambient air leak utilize the Control Operation Service section and adjust unit to defrost every 9 hours...

Страница 48: ...irculate air and clear any condensation that may have appeared on glass doors and shelves Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door swi...

Страница 49: ...t fan mounting location 13 Installation is the reverse of removal 14 Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge of the train trough 15 Use sea...

Страница 50: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...