background image

USER GUIDE

Cleaning

INTERIOR CLEANING & SANITIZING

NOTICE
Do not use any solvent-based or abrasive 
cleaners.

 These types of cleaners may transfer taste  

and/or odor to the interior products and damage or  
discolor the interior.

DEFROSTING

Under normal conditions this unit does not require manual 
defrosting. Minor frost on the rear wall or visible through 
the evaporator plate vents is normal and will melt during 
each cycle.

If there is excessive build-up of 1/4” (6 mm) or more, 
manually defrost the unit.

Ensure the door is closing and sealing properly.

High ambient temperature and excessive humidity can also 
produce frost.

CAUTION

!

DO NOT use an ice pick or other sharp instrument 
to help speed up defrosting. These instruments 
can puncture the inner lining or damage the 
cooling unit. DO NOT use any type of heater to 
defrost. Using a heater to speed up defrosting can 
cause personal injury and damage to the inner 
lining.

NOTICE

The drain pan was not designed to capture the 
water created when manually defrosting. To 
prevent water from overflowing the drain pan 
and possibly damaging water sensitive flooring, 
the unit must be removed from cabinetry.

To defrost:

1.  Disconnect power to the unit.

2.  Remove all products from the interior

3.  Prop the door in an open position (2 in. [50 mm] 

minimum).

4.  Allow the frost to melt naturally.

5.  After the frost melts completely, clean the interior and 

all removed components. (See INTERIOR CLEANING).

6.  When the interior is dry, reconnect power and turn 

unit on.

24

Содержание UCBR532-SS01A

Страница 1: ...USER GUIDE SERVICE MANUAL Model UCBR532 SS01A...

Страница 2: ...tallation Door Swing Door Adjust Interior Adjustments Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Airflow and Product Loading Service Wi...

Страница 3: ...HT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are available digi...

Страница 4: ...uide This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervisio...

Страница 5: ...ee of obstruction Obstructing free airflow can cause the unit to malfunction and will void the warranty Failure to clean the condenser every six months can cause the unit to malfunction This could voi...

Страница 6: ...e so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refriger...

Страница 7: ...uce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present con...

Страница 8: ...it Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been pl...

Страница 9: ...UTOUT PRODUCT DIMENSIONS UCBR532 UCBR632 NOTE THE HOLE CUTOUTS ON TOP SURFACE APPLY TO THE UCBR632 ONLY AND ARE CUTOUT AT THE FACTORY FRONT TOP SIDE 9 31 32 253mm 12 31 32 329mm 7 178mm 32 813mm 24 3...

Страница 10: ...1 4 489mm 28 711mm 24 3 4 629mm 18 1 2 470mm 43 1 4 1099mm 24 3 4 629mm 26 19 32 676mm 52 1321mm 20 508mm 24 23 32 628mm 12 31 32 329mm 7 178mm 2 3 4 70mm 1 25mm Preferred location for electrical out...

Страница 11: ...19 1 4 489mm 24 3 4 629mm 43 1 4 1098mm 18 1 2 469mm 24 3 4 629mm 26 19 32 675mm 72 1829mm 24 3 4 628mm 20 1 8 511mm 20 508mm 12 31 32 329mm 7 178mm 2 3 4 73mm 1 35mm If Unit has Legs Add 6 6 3 4 if...

Страница 12: ...12 31 32 329mm 7 178mm 2 3 4 70mm 1 25mm 92 2337mm 19 1 4 489mm 34 9 16 878mm 30 7 16 773mm 28 711mm 24 3 4 629mm 18 1 2 469mm 43 1 4 1098mm 24 3 4 629mm 26 19 32 276mm Preferred location for electri...

Страница 13: ...ference tap holes in air duct below lid It is recommended to insulate any tubing inside of the air duct to avoid freezing Left hand units are dimensionally opposite left to right DRILL AREA 4 102mm 15...

Страница 14: ...orten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is correctly positioned in t...

Страница 15: ...the unit the grille must be installed Removing the grille 1 Disconnect power to the unit 2 Remove two top screws and two bottom screws 3 Remove grille and set aside Installing the grille 1 Align cabin...

Страница 16: ...its have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Wa...

Страница 17: ...site side of the cabinet TO REVERSE THE DOOR Note When reversing the door the top hinge becomes the bottom hinge on the opposite side of the unit likewise the bottom hinge becomes the top on the other...

Страница 18: ...TALL DOOR ONTO UNIT Note To prevent damage and to have two hands free it may be beneficial to have someone hold the door during the installation 1 Lift door at a slight angle upward to allow the hinge...

Страница 19: ...ing towards the selected temperature Time to reach set point varies based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the unit to reach set poin...

Страница 20: ...press and release to scroll through lighting options Option Open Door Closed Door 00 White White 01 Blue Blue 02 White Blue Light will be set at full intensity when door is open and 50 intensity when...

Страница 21: ...e of the unit Do not install behind a closed door Internal When loading leave space between internal fans vents and side walls to allow air to circulate freely NOTICE Restricting airflow may result in...

Страница 22: ...move the 4 Shelf clips from the shelf clip holes 2 Move shelf clips as a group to the desired shelf height 3 Insert shelf clips into the holes of the desired shelf height Be certain shelf clip is full...

Страница 23: ...p promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible CLEAN INTERIOR COMPONENTS Use warm or hot water with dish soap to clean all removed com...

Страница 24: ...ce pick or other sharp instrument to help speed up defrosting These instruments can puncture the inner lining or damage the cooling unit DO NOT use any type of heater to defrost Using a heater to spee...

Страница 25: ...vironmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condense...

Страница 26: ...cabinet 1 Grasp the front end of the rack and insert into the cabinet 2 Tilt the front end of the rack upward and align the left and right upper tabs with the slots in the rear shelf ladder at the des...

Страница 27: ...allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 Clean the system See CLEANING 6 The door must remain open to prevent formation of...

Страница 28: ...akes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before d...

Страница 29: ...ing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal temperatures of th...

Страница 30: ...USER GUIDE Wire Diagram 32 52 30...

Страница 31: ...USER GUIDE Wire Diagram 72 92 31...

Страница 32: ...in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the date and the servicer...

Страница 33: ...r warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update warran...

Страница 34: ...ranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform...

Страница 35: ...IDE u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE R 600A Specifications For R 600a refrigerant service tips and more videos go to www u line com videos WARNING...

Страница 36: ...nded that a simple LPG gas detector is on site during service Ensure that all R290 R600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system sho...

Страница 37: ...for nitrogen helium leaks Never use a halide torch or lighted match to check the system for leaks at any time The high side of the refrigeration system compressor discharge to outlet of drier must be...

Страница 38: ...e refrigeration system R290 R600a refrigerant or dry nitrogen only Never use a torch on a fully charged refrigeration system Install a Schrader Type access port on the compressor process stub The filt...

Страница 39: ...e Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lowe...

Страница 40: ...lectrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components Compressor Specifications FMXA9C REFRIGERANT R600A VOLTAGE 230 VAC FREQUENCY 43 134 Hz START WINDI...

Страница 41: ...for assistance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Despite t...

Страница 42: ...OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry Check distribution of product in unit Thermistor failure OHM thermistor Displa...

Страница 43: ...ger Switch Replace Main Board Replace Fuse Replace Power Cord Alert Customer Of Power Failure Is the Plunger Switch Operating Properly Inspect Customer UI and Data Cable Connect Test Display Cycle Pow...

Страница 44: ...ce Mode This mode has options available for service diagnostics To enter the mode hold the hidden key for 10 seconds The display will show O When in this mode use the up and down arrows to select the...

Страница 45: ...Thermistor If the zone thermistor in the unit fails the unit will continue to cool in a backup mode Self Preservation Mode to preserve the integrity of the contents The unit will otherwise operate no...

Страница 46: ...UIDE Defrost Defrost If you have verified that the unit does not have an ambient air leak utilize the Control Operation Service section and adjust unit to defrost longer and or more less often as need...

Страница 47: ...r box cover Take out the four long screws and set the cover aside exposing the evaporator compartment 3 Remove the evaporator air deflector cooling baffle by sliding it out and set aside 4 Remove 4 sc...

Страница 48: ...he mounting bracket 7 Installation is the reverse of removal 8 Take special care to properly route wires away from fans and copper tubing and make sure fan motor is secured in rubber gasket 9 Use seal...

Страница 49: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Отзывы: