background image

USER GUIDE & SERVICE MANUAL

Model: U-29RB-00A

Содержание U29RB00A

Страница 1: ...USER GUIDE SERVICE MANUAL Model U 29RB 00A...

Страница 2: ...stallation General Installation Grille Plinth Installation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Airflow and Product Loading...

Страница 3: ...HT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are available digi...

Страница 4: ...oderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do n...

Страница 5: ...e so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refriger...

Страница 6: ...ures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating e...

Страница 7: ...e unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has bee...

Страница 8: ...air space for top sides or rear However the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear CAUTION Unit can NOT be installed behind a closed cab...

Страница 9: ...cording to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown bel...

Страница 10: ...he opening Readjust the front to level the unit after it is correctly positioned in the opening INSTALLATION 1 Plug in the power electrical cord 2 Gently push the unit into position Be careful not to...

Страница 11: ...e SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Remove control knob 4 3 Loosen the two screws 1 4 Remove grille 2 and grille cap 3 from unit Installing the grill...

Страница 12: ...its have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Wa...

Страница 13: ...und the door no gaps 4 Tighten bottom hinge screws 5 Tighten top hinge screws REVERSING THE DOOR Location of the unit may make it desirable to mount the door on the opposite side of the cabinet The hi...

Страница 14: ...inge Install two or three screws depending on model Replace nuts if used Install top hinge and door 1 Rotate door 180o and lift the door on to the bottom hinge 2 Install hinge that was used on the opp...

Страница 15: ...ch located below the temperature control dial in the center of the grille CONTROL DIAL The control dial sets a single continuous temperature This set point temperature is a base setting used by the co...

Страница 16: ...es Not all bottles and cans will fit on every shelf and wine rack Larger diameter champagne and Magnum bottles only fit on wine racks when noted on the product specifications When determining capaciti...

Страница 17: ...ws 1 To move to a different position in the unit insert shelf at an angle approximately 15 20 over the rib in the side of the unit where you want to place the shelf Place the shelf into the unit at an...

Страница 18: ...discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Clea...

Страница 19: ...TICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or other absorbent materials over the interior dr...

Страница 20: ...g on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The co...

Страница 21: ...allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 Clean the system See CLEANING 6 The door must remain open to prevent formation of...

Страница 22: ...akes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before d...

Страница 23: ...ing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal temperatures of th...

Страница 24: ...OUND GREEN or GREEN W YELLOW 115 VOLT PLUG 220 240 VOLT PLUG CONTROL SEE COMPRESSOR DIAGRAMS BLUE BLACK HOT SMOOTH BLACK NEUTRAL RIBBED BLACK WHITE FAN WHITE BLACK RED BLUE BROWN NEUTRAL HOT RELAY EMB...

Страница 25: ...replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the dat...

Страница 26: ...r warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update warran...

Страница 27: ...BLY 80 54192 00 9 CONTROL KNOB 80 54975 00 10 DOOR ASSEMBLY BLK 29RB W HINGES 80 54514 01 11 DRAIN PAN 80 54217 00 12 DRAIN TROUGH ASSEMBLY 80 54520 00 13 DRIER 80 54055 00 14 EVAPORATOR ASSEMBLY 80 5...

Страница 28: ...ranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform...

Страница 29: ...ust observe all federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder type fi...

Страница 30: ...pump and recovery equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system p...

Страница 31: ...is left within the system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing the sy...

Страница 32: ...ll a Schrader Type access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minu...

Страница 33: ...cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near room te...

Страница 34: ...rozen CHECK TERMINAL PINS To measure the start winding resistance measure across the C and S pins To measure the run winding resistance measure across the C and R pins Also check S to R and you should...

Страница 35: ...or perform maintenance on the unit until the main electrical power has been disconnected from the unit TROUBLESHOOTING GUIDE Concern Potential Causes Action Not Cooling Compressor overheating Verify p...

Страница 36: ...or The pressure of the refrigerant is reduced to the evaporating or low side pressure The reduction of pressure on the liquid refrigerant causes it to boil or vaporize until it reaches saturation temp...

Страница 37: ...IDE Defrost 1 Defrost These units are automatic cycle defrost unit will defrost itself when the control sensor is satisfied of internal temperatures Defrost mode ends when control sensor asks for cool...

Страница 38: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...