U-Line U-2218RGLINT-00A Скачать руководство пользователя страница 1

USER GUIDE & SERVICE MANUAL

Model: U-2218RGLINT-00A

Содержание U-2218RGLINT-00A

Страница 1: ...USER GUIDE SERVICE MANUAL Model U 2218RGLINT 00A ...

Страница 2: ...nsions Integrated Panel Installation Grille Plinth Installation Door Swing Door Stop Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Sabbath Mode Airflow and Product Loading Service Interior Shelves Troubleshooting Wire Diagram Product Liability Warranty Claims Parts Ordering Replacement Parts R600a Specifications System Diagn...

Страница 3: ...rldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U...

Страница 4: ...or death WARNING Warning means that failure to follow this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage DANGER This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to e...

Страница 5: ...er take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refrigeration appliances and follow these steps completely 1 Remove all consumable contents from the unit 2 Unplug the electrical cord from its socket 3 Remove t...

Страница 6: ...C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation will ...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breake...

Страница 8: ...ont grille plinth strip base fascia must NOT be obstructed CAUTION Unit can NOT be installed behind a closed cabinet door U Line products are designed and manufactured to be installed in the specified cutout openings shown and variance to the floors or cabinetry must be accounted for in your installation CUTOUT DIMENSIONS Metric measurements rounded and optimized 4 102 mm 7 178 mm 17 7 8 455 mm 33...

Страница 9: ...mensions 1 SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 33 11 16 to 34 11 16 856 mm to 881 mm 23 7 16 590 mm 17 3 4 450 mm 3 5 16 84 mm Includes 3 4 20 mm integrated panel 9 ...

Страница 10: ...ensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintained between the units Hinge by Hinge Installation Mullion When installing two units hinge by hinge 13 16 22 mm is required for integrated models Additional space may be ...

Страница 11: ... a 2 Phillips head screwdriver 3 Completely slide the unit into its position in the cabinet Be certain unit height is properly adjusted See GENERAL INSTALLATION 4 Open door completely Make certain door clears surrounding cabinetry 5 Using a 3 32 drill bit drill 3 pilot holes 5 8 16 mm deep into bottom of counter top Use the anti tip bracket as a template 6 Install the 3 remaining 8x5 8 screws into...

Страница 12: ...GRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 5 Using a 3 32 drill bit drill 3 pilot holes 5 8 16 mm deep into cabinetry frame using the anti tip bracket as a template 6 Install the 3 remaining 3 8x5 8 screws into the plate using a 2 Phillips head screwdriver 12 ...

Страница 13: ...l unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adjust the front legs to level the unit after it is correctly positioned in the opening INSTALLATION 1 Plug in the power electrical cord 2 Gently push the unit into position Be careful not to entangle the cord ...

Страница 14: ... 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed in the diagram below 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optional Install handles and hardware NOTICE When a...

Страница 15: ...pliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared frame with insert must not weigh more than 20 lbs 10 kg Integrated Frame Preparation 1 Cut the main panel to the dimensions below For details see the drawings on the next page 2 Create the top design for the handleless feature and the 1 8 3 mm notch for the insert s indica...

Страница 16: ... Handleless Integrated Frame Dimensions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R 16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref Top Detail Insert Notch Top Design 1 8 3 mm 3 1 2 89 mm 17 5 8 445 mm Wooden Insert Dimensions 17 5 8 445 mm Cutout for Frame Units 16 ...

Страница 17: ...nsions listed in the appropriate diagram on the next page 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optional Install handles and hardware NOTICE The door panel must not weigh more than 20 lbs 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in t...

Страница 18: ...nel Integrated Panel Integrated Frame Front Side Front Side 3 5 16 89 mm to 4 5 16 114 mm Floor Cabinet 3 5 16 89 mm 3 5 16 89 mm to 1 25 mm U Line Unit Extended Integrated Panel Extended Integrated Frame Floor Cabinet 3 5 16 89 mm to 1 25 mm U Line Unit Integrated Panel Panel can extend beyond the door frame A minimum of 1 25 mm from the floor is required for proper ventilation 18 ...

Страница 19: ...egrated frame is 2 3 4 70 mm The top bottom border of the frame must account for any additional length BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT INTEGRATED FRAME FLAT AND WITHOUT INTERFERENCE 17 5 8 445 mm 3 4 20 mm 2 3 4 MIN 70 mm MIN Integrated Frame 30 0 33 7 8 762 mm 860 mm A minimum of 1 25 mm is required from the floor to the bottom of the extended integrated panel frame for proper ...

Страница 20: ...l to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish application and cure times 3 Apply double sided tape to the backside of the integrated grill plinth strip base fascia Use the diagram below for reference U Line recommends 3M VHB tape a high strength bonding tape 4 Remove backing paper from double side...

Страница 21: ...door using clamps A robust tape may also be used U Line recommends the use of bar clamps to secure the panel to the door If using tape be certain the tape will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to ensure that all drilled holes are drilled to th...

Страница 22: ...ush against the bottom of the channel 11 Remove clamps from door NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion 12 Starting at the corners re install the gasket into the gasket channel in the frame Make sure the gasket is fully seated This may take some force Integrated Panel Integrated Pa...

Страница 23: ...ia When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille plinth strip base fascia 1 Disconnect power to the unit 2 Loosen the two screws 1 3 Remove grille plinth strip base fascia 2 from unit Installing the grille 1 Align cabinet and grille holes and secure but do ...

Страница 24: ... the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door clearance on hinge side to allow for door handle Units have a zero clearance when installed adjacent to cabinets Wall Wall 90 Door Swing 90 Door Swing Space Required For any Knobs or Pulls 2 1 4 MIN 57 m...

Страница 25: ...ximately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin should slide into place stopping the door at 90 if the pin does not go into the hole shown hold the door less than 90 open and try again 4 To fully seat the pin tap it lightly with a hammer 5 Carefully slide your...

Страница 26: ...the cabinet all the way around the door no gaps Carefully examine the door s gasket to ensure that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to raise or pivot your unit This would put excessive stress on the hinge system Alignment and Adjustment Procedure 1 Remove integrated panel if i...

Страница 27: ... factory Initial startup requires no adjustments NOTICE U Line recommends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the factory default settings If the unit was turned off during installation simply press and the unit will immediately switch on To turn the unit off press 27 ...

Страница 28: ...UNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door wine and beverage centers only Adjust refrigerator set point Press and release When the F or C in the display is flashing press to adjust the set point temperature View temperature in unit Press together and r...

Страница 29: ...internal temperatures and set points View a full list of Star K certified U Line units at www star k org To enable Sabbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will flash briefly at the end of the ten second period 2 The interior light and control display 3 will go dark until user resets mode 3 NOTE Although the display will not be visible the temperature controls in ...

Страница 30: ... space between the internal fans or vents and product loaded Anything blocking the required airflow circulation will result in uneven temperature distribution in the cabinet and can also freeze product Do not install the unit behind a door When properly loaded your U Line unit will store up to 123 12 oz 330 ml cans or 79 12 oz 330 ml bottles For optimal airflow leave approximately two inches of sp...

Страница 31: ...ght Shelf height may be adjusted to accommodate a broad range of product To alter your shelf spacing follow the instructions below 1 Remove the 4 Shelf clips from the shelf clip holes 2 Move shelf clips as a group to the desired shelf height 3 Insert shelf clips into the holes of the desired shelf height Be certain shelf clip is fully seated into shelf clip hole CAUTION Clips MUST be installed wit...

Страница 32: ...brite will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels use household cleaner per the cabinet manufacturer s recommendation INTERIOR CLEANING Disconnect power to the unit Clean the interior and all removed com...

Страница 33: ...in pan and possibly damaging water sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 Allow the frost to melt naturally 5 After the frost melts completely clean the interior and all removed components See INTERIOR CLEANING 6 When the interior is dry rec...

Страница 34: ...cessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condenser unit Condenser may be cleaned using a vacuum soft brush or compressed air 1 Remove the grille plinth strip base fascia See GRILLE PLINTH INSTALLATION 2 Clean the condenser c...

Страница 35: ... returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or less the steps above mu...

Страница 36: ...ed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Condenser Fan Air moving through a condenser may be heard Automatic Defrost Drain Pan Water may be heard dripping or running into the drain pan when the unit is in the defrost cycle TROUBLESHOOTING GUIDE DANGER ELECTROCUTION...

Страница 37: ...ings and the time the door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Digital Display Shows 1 16 or 99 A factory test mode may be enabled Adjust the temperature to 99 and press the LIGHT icon Product Is Freezing Because product in contact with the rear wall may freeze ensure no product is touching the rear wall Adjust the temperature to ...

Страница 38: ...O COMPRESSOR 1 10 CONTROL BOARD ZONE TEMP FUSE T O D I S P L A Y 115 VOLT PLUG 220 240 VOLT PLUG 16 8 9 1 NEUTRAL WHITE 115v DARK BLUE 220 240v TO COMPRESSOR 6 1 10 5 T O U S B ZONE EVAP DOOR SWITCH AMBIENT TEMP TEST TERMINAL LIGHT EVAP FAN CONDENSER FAN GROUND GREEN or GREEN W YELLOW NEUTRAL WHITE 115v DARK BLUE 220 240v P R O G R A M I N G OPEN NEUTRAL HOT RELAY EMBRACO COMPRESSOR GREEN or GREEN...

Страница 39: ...f a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the date and the servicer who removed the part If the service technician determines the damage is the result of installation issues water connection drain etc the consum...

Страница 40: ... 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may submitted with the warranty claim to document warranty status We also accept the following information to verify warranty status New Construction Occupancy Documents Closing Paperwork Final Billing Remodel ...

Страница 41: ... 80 54152 00 16 Evaporator cover 80 54021 00 17 Gasket door injection molded 80 54003 00 18 Gasket door for extrusions 80 54415 00 19 Glass shelf 1 w brackets 80 54015 00 20 Grille w screws 80 54011 00 21 Hinge covers 2 pcs 80 54001 00 22 Hinge mounting hole covers 80 54024 00 23 Hinges 2 w screws and covers 80 54013 00 24 LED light strip and cover assy 80 54000 00 25 Leg Levelers 4 80 54019 00 26...

Страница 42: ...ll be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform you when the parts order is taken This requirement will be noted on your packing list A prepaid shipping label will be included with the replacemen...

Страница 43: ...al state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder type fire extinguisher in the work area R 600a is heavier than air do not allow any leakage migration to low areas such as basements and stairs Never use a torch on a fully charged refrigeration system Never substitute U Line OE...

Страница 44: ...ipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should be charged with R 600a R 600A SPECIFICATIONS LABELING R 600a equipped products are labeled both the unit and the compressor R 600a is ...

Страница 45: ...stem prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing the system must be purged with dry nitrogen and at least one access point open to the atmosphere When re brazing proper ventilation is required along with constant monitoring for the presence of R600a refrigerant The filter dry...

Страница 46: ...cess port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal must be used to close the system SUMMARY Safely handling R 600a requires proper procedures and training R 600a approved service tool...

Страница 47: ...er than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near room temperature due to liquid Room temperature cool or colder Extremely cold near inlet Outlet below room temperature backing up Lower than ...

Страница 48: ...rap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S pins To measure the run winding resistance measure across the C and R pins Also check S to R and you should get the sum of the run and start windings To ensure the windings are not shorted check the S an...

Страница 49: ...dy Not Cooling Compressor overheating Verify proper air flow through condenser Is condenser clean Confirm condenser fan operation Confirm proper compressor operating voltage Use 19 Component Testing in Service Mode Compressor not operating Confirm proper compressor operating voltage Use 19 Component Testing in Service Mode Test overload and relay replace as needed Compressor operating no cooling R...

Страница 50: ... the unit does not or seems to not power on follow the flow chart below to help diagnose the issue Before beginning it is important to first verify the unit is not simply set to sabbath mode System Condition Suction Pressure Suction Line Compressor Discharge Condenser Capillary Tube Evaporator Wattage Normal Normal Slightly below room temperature Very hot Very hot Warm Cold Normal Overcharge Highe...

Страница 51: ... have been ruled out as being faulty but the unit continues to have operating issues it is most likely due to a configuration error Configuration errors can be cleared by restoring the unit to its factory default setting Factory defaults may be restored through the service menu CAUTION Precautions must be taken while working with live electrical equipment Be sure to follow proper safety procedures...

Страница 52: ...ill otherwise operate normally Evaporator thermistor errors will be displayed in the error log Always assure that all thermistor connections are clean and dry Whenever opening a thermistor connection be sure to apply a fresh dab of die electric grease REED SWITCH A reed switch is used to monitor door state When the door is closed magnetic force pulls the reed to its contact and closes the circuit ...

Страница 53: ...ture Navigates through service menu LED activated with button activation 4 Light Button Activates light for 3 hours on select models Used to select items in service menu LED activated with button activation 5 Power Button Turns unit off on LED activated with button activation only turning unit off 6 Clean Button Activates Clean Cycle on CLR models LED activated with button activation 7 Alert LED N...

Страница 54: ... begin to flash When the degree symbol is flashing the unit will allow the use of the control for demonstrations The unit can be left in this mode indefinitely To exit this mode interrupt power to the unit 3 SERVICE MODE This mode has 28 different options available for service diagnostics To enter the mode hold the hidden key for 10 seconds The display will show 0 When in this mode use the up and ...

Страница 55: ... icon to enter and save change 14 Display error log Use up down to access and light bulb key to view 15 Clear error log Use up down to access and light bulb key to clear 16 View thermistor 1 differential Do not make any changes to this 17 Fan on delay start of cooling cycle Up down to select light icon to enter and save change 18 Fan off delay after cooling cycle stops Up down to select light icon...

Страница 56: ... VIEW THERMISTOR 2 SET POINT MINUS OFFSET 10 Does not apply to this model 11 Does not apply to this model 12 DEFROST INTERVAL ADJUST 3 TO 24 HOURS This will adjust the interval between defrosts from 3 to 24 hours Adjusting from the factory settings may cause undesired temperature in the refrigerator section 13 DEFROST LENGTH ADJUSTMENT UP TO 99 MINUTES The length of the defrost can be adjusted up ...

Страница 57: ...rs 23 COMPRESSOR RUNTIME BASED ON LAST CYCLE This will show the number of minutes the compressor has run in the prior cycle or current cycle if the compressor was running when service mode was entered 24 ACTIVATE DEFROST Turns on the hot gas bypass valve allowing hot gas to circulate through the evaporator causing frost to melt 25 RESTORE FACTORY DEFAULTS Will restore all adjustable functions to t...

Страница 58: ...s F C Defrost Duration Minutes 45 Next Defrost Hours 12 Thermistor Four OFFSET 0 Thermistor Three OFFSET 0 Thermistor Two OFFSET 0 Thermistor One OFFSET 7 Thermistor One Differential Up 1 Thermistor One Differential Down 1 Thermistor Four Set Point 0 18 Thermistor Three Set Point 0 18 Thermistor Two Set Point 42 6 Refrigeration Set Point 38 3 Light Key 0 Has Ice 0 Maximum Ice Set Point 42 6 Minimu...

Страница 59: ...s two thermistors Thermistor one is located along the right hand side wall inside of the unit and is used to maintain temperature within the unit Thermistor two is located on the back of the evaporator and is used for defrost purposes Thermistor connections must be kept clean A thermistor connection that has become corroded can cause resistance values from the thermistor to change as they pass thr...

Страница 60: ...E Defrost These units are frost free technology Model Hrs Between Defrost Time Length Minutes Stop Point 2218R WC 12 45 42 2224BEV R WC 12 45 42 3018R WC 12 45 40 1224DWR 12 45 42 1224WC 12 45 45 3024DWR FZR BEV R 12 42 40 3036BVWC RR WCWC 12 42 40 C01224F 12 18 42 C029F 12 18 1224RF 12 18 42 60 ...

Страница 61: ...sation that may have appeared on glass doors and shelves Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door switch In order to operate efficiently the evaporator fan blade and vents should be unobstructed and free of any dust buildup Evaporator Fan Replacement Should the evaporator fan need to be replaced follow the steps below 1 Remove any p...

Страница 62: ... cover vents and push air out at fan mounting location 15 Installation is the reverse of removal 16 Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge of the train trough 17 Use sealant gum to seal any openings at rear of unit before replacing rear cover 18 Reinstall unit taking care to level space and secure as found 62 ...

Страница 63: ... improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U Line will provide either under these warranties or under any warranty arising by operation of law U Line will not be responsi...

Отзывы: