Содержание U-1024RS-00A

Страница 1: ...USER GUIDE SERVICE MANUAL SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 1000 Series 1024R 24 Refrigerator RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Страница 2: ...i Tip Bracket General Installation Grille Plinth Installation Door Swing Door Stop Door Adjust Free Standing Kit Operating Instructions First Use Airflow and Product Loading Interior Shelves Maintenan...

Страница 3: ...decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Pr...

Страница 4: ...jury or death WARNING Warning means that failure to follow this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may...

Страница 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Страница 6: ...F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...

Страница 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Страница 8: ...tion When built in your unit does not require additional air space for top sides or rear However the front grille must NOT be obstructed and clearance is required for an electrical connection in the r...

Страница 9: ...duct Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 34 1 8 to 35 1 8 867 mm to 892 mm 24 610 mm 3 9 16 91 mm Not Including Handle...

Страница 10: ...rly grounded electrical receptacles placed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are e...

Страница 11: ...5 models only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighte...

Страница 12: ...adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be ge...

Страница 13: ...ING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Remove control knob 3 3 Loosen the screw 1 in the center...

Страница 14: ...ed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance...

Страница 15: ...ing conditions It is not designed for excessive force Do not use the door to move the unit in out of the cutout during installation If your unit is already undercounter it might need to be moved out f...

Страница 16: ...e door TO ALIGN AND ADJUST THE DOOR Remove grille Remove the grille see GRILLE PLINTH INSTALLATION section of this guide 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with c...

Страница 17: ...epare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove plunger bracket from door with T 10 TORX driver Be sure to only remove the two screws hol...

Страница 18: ...wed to open past 90 do not require this step 1 Remove wine rack see WINE RACK INSTALLATION in Maintenance 2 Starting from the side that has the spacers previously unaltered units will be on the right...

Страница 19: ...ly used when unit is not installed in surrounding cabinetry To install the kit 1 Remove grille see GRILLE PLINTH INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligni...

Страница 20: ...recommends allowing the unit to run overnight before loading with product MECHANICAL DIAL CONTROL The control dial turns unit ON OFF and sets temperature This set point temperature is a base setting...

Страница 21: ...o perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between the evaporat...

Страница 22: ...t by pulling out 3 Insert the shelves as follows 1 To move to a different position in the unit insert shelf at an angle approximately 15 20 over the rib in the side of the unit where you want to place...

Страница 23: ...ass tile and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finis...

Страница 24: ...sonal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or...

Страница 25: ...necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the con...

Страница 26: ...cabinet interior and will compromise the precise temperature control of the unit 1 Find the light located at the top of the unit Grasp the edges of the light housing lens 1 opposite the exposed tab an...

Страница 27: ...it is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open...

Страница 28: ...igeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing soun...

Страница 29: ...erature setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door openings and the time the door is open The time the internal light is illum...

Страница 30: ...ranty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty whether express implied o...

Страница 31: ...CE Wire Diagram 42342_A WIRING DIAGRAM GROUND GREEN or GREEN W YELLOW NEUTRAL HOT RELAY EMBRACO COMPRESSOR GREEN or GREEN W YELLOW GROUND 115 VOLT PLUG 220 240 VOLT PLUG OVERLOAD CAP CONTROL DOOR SWIT...

Страница 32: ...ment of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial nu...

Страница 33: ...dashes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may...

Страница 34: ...215 00 11 Drain pan w double sided tape 80 54217 00 12 Drier 80 54055 00 13 Evaporator assembly 80 54275 00 14 Glass shelf 1 w edge trim 80 54277 00 15 Grille w screws 80 54207 00 16 Handle w logo 80...

Страница 35: ...rts will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U...

Страница 36: ...ge Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near...

Страница 37: ...ist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and...

Страница 38: ...nance on the unit until the main electrical power has been disconnected from the unit TROUBLESHOOTING GUIDE Concern Potential Causes Action Not Cooling Compressor overheating Verify proper air flow th...

Страница 39: ...of the refrigerant is reduced to the evaporating or low side pressure The reduction of pressure on the liquid refrigerant causes it to boil or vaporize until it reaches saturation temperature As the l...

Страница 40: ...ION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Defrost These units are automatic cycle defrost unit will defrost itself when the control sensor is satisfied of internal temperatures Defros...

Отзывы: