8

CAUTION

!

Plumbing installation must observe all state and local 
codes. All water and drain connections MUST BE made by 
a licensed/qualified plumbing contractor. Failure to follow 
recommendations and instructions may result in damage 
and/or harm.

Water Supply Connection

When connecting the water supply, follow these guidelines:

• Review the local plumbing codes before you install the unit.
• Connect to the cold water supply.
• The water pressure should be between 20 and 120 psi.
• The water line MUST have a shut-off valve in the 1/4" O.D. 

supply line.

• Leave approximately 8' of water line to be coiled behind the 

appliance. The water line should be looped into 2 coils. This 
will allow the unit to be removed for cleaning and servicing. 
However, make certain that the tubing is not pinched or 
damaged during installation.

NOTICE

U-Line requires the use of copper tubing for installation. 
Do not use any plastic water supply line. The line is under 
pressure at all times. Plastic may crack or rupture with 
age and cause water damage to your home.

1. For units with front mounted water solenoids you must 

remove the grille

1. Install the 1/4-inch OD copper water line to the main water 

source.

2. Locate the compression fitting and 

ferrule packed with the unit. Slide the 
compression fitting and ferrule over the 
1/4-inch OD water supply line. Do not 
use thread sealing compound or tape. 
Using two wrenches, tighten the 
compression fitting on the supply line.

3. Carefully bend the water supply line into position and connect 

the line to the solenoid valve. Avoid kinking the water supply 
line.

NOTICE

For units with front mounted water solenoids, route the 
water supply line through the unit so it does not come 
into contact with any internal components other than the 
solenoid valve. Normal operation creates some vibration. 
A water supply line contacting an internal component or 
cabinet wall can cause excessive noise during operation or 
damage to the line.

4. For recessed installations, allow extra water supply line length to 

provide slack for easy removal from the recessed area. This will 
also safeguard against kinking the line. 

10 Plumbing

Water

Connection

Rear Mount

Water Line

Front Mount

Содержание ICEMAKER Series

Страница 1: ...115S 22 U BI2115W 20 ULN BI95B 00 ULN BI95B 20 ULN BI95BTP 03 ULN BI95BTP 20 ULN BI95WH 00 ULN BI95WH 20 BI95 U ADA15IMB 00 U ADA15IMS 00 U ADA15IMS 01 ULN BI98B 00 ULN BI98B 20 ULN BI98WH 00 ULN BI98...

Страница 2: ...BI95 BI95BTP BI98 BI2115 5 SS1095 SP18 BCM95 WH95 6 Door Swing Dimensions 7 5 Other Site Requirements Power Supply 7 Water Supply 7 Environmental Requirements 7 6 Door Reversal BI95 BI98 8 WH95TP BI95...

Страница 3: ...place so children may not easily climb inside WARNING SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected...

Страница 4: ...TERHOOKUP Exterior Cleaning Black and White Models Black and White surfaces may be cleaned with a mild detergent and warm water solution Do not use solvent based or abrasive cleaners Use a soft sponge...

Страница 5: ...t Height 25 1 16 Filler Panel Not Provided by U Line May Be Added Above or Below Unit to Enclose for a Built In Look 14 3 16 18 1 2 Minimum See Electrical Specifications for Power Supply 8 Typical Cou...

Страница 6: ...4 1 4 Cut Out Width 3 4 Minimum Flange Mounting Area 3 4 Minimum Flange Mounting Area Cut Out Height 26 1 16 Filler Panel Not Provided by U Line Needed to Attach Mounting Flange on Unit 18 1 2 Minimum...

Страница 7: ...ance 15 34 1 8 3 13 16 23 1 8 BI2115 Stainless Add 1 1 2 For Water Line Clearance 25 1 16 13 15 16 17 8 15 16 BI95BTP BI98 SS98 27 3 8 14 15 16 20 Add 1 1 2 For For Water Line Clearance 8 15 16 17 25...

Страница 8: ...arance 17 25 1 8 15 1 8 9 Add 1 1 2 For Water Line Clearance 25 1 16 14 17 9 15 1 8 24 1 2 18 7 8 7 9 16 1 2 Add 1 1 2 ForWater Line Clearance BCM95 WH95TP 17 25 1 8 14 8 15 16 Add 1 1 2 For For Water...

Страница 9: ...e models with ice makers If the ambient temperature is expected to drop below 45 F 7 C drain all water from the unit to prevent freezing damage which is not covered by the warranty For best performanc...

Страница 10: ...door on bottom hinge pin See Figure 5 Clean out bushing hole in door bottom with a screwdriver if necessary 6 Remove plastic hole plug from door handle and relocate on opposite side See Figure 6 7 Rem...

Страница 11: ...or on bottom hinge pin See Figure 14 Clean out bushing hole in door bottom with a screwdriver if necessary 7 Remove plastic travel pin from door handle and relocate on opposite side See Figure 15 8 Re...

Страница 12: ...from the original location and remove the handle Remove the two screws on the opposite side of the door Figure 25 Do not place handle on door until you have completed steps 9 10 9 Remove plastic hole...

Страница 13: ...unit Figure 29 Be sure to tighten all three screws securely 15 Place door on lower hinge pin Invert and install upper hinge on door Fasten upper hinge to unit three screws Figure 30 Partially tighten...

Страница 14: ...om hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force 3 Remove the two outside screws holding door ha...

Страница 15: ...oles in hinge and hinge plate 8 Mount the door install top hinge pivot pin All Other Models 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet Make sure gasket is fi...

Страница 16: ...upture with age and cause water damage to your home 1 For units with front mounted water solenoids you must remove the grille 1 Install the 1 4 inch OD copper water line to the main water source 2 Loc...

Страница 17: ...main water source 5 Plug in the powercord 6 Gently push the unit into position Be careful not to kink the water supply line or entangle the electrical cord 7 Re check the leveling from front to back a...

Страница 18: ...ic Problem Q The door remains open unless it is pushed closed Solution A The hinges should be self closing when the door is open approximately 8 If this is not the case make sure the closers are clean...

Страница 19: ...ne Captain Models Combo Models Refrigerator Freezers Refrigerators Drawer Models and Beverage Centers The U Line brand offers products in the 1000 Series 2000 Series and the Modular 3000 Series The 10...

Отзывы: