Страница 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 1000 Series 1224R 24 Solid Door Refrigerator RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...
Страница 2: ...Integrated Panel Installation Grille Plinth Installation Door Swing Door Stop Door Adjust Free Standing Kit Operating Instructions First Use Control Operation Sabbath Mode Airflow and Product Loading...
Страница 3: ...ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all ava...
Страница 4: ...jury or death WARNING Warning means that failure to follow this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may...
Страница 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...
Страница 6: ...F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...
Страница 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...
Страница 8: ...tion When built in your unit does not require additional air space for top sides or rear However the front grille must NOT be obstructed and clearance is required for an electrical connection in the r...
Страница 9: ...ensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 3 9 16 91 mm 34 1 8 to 35 1 8 867 mm to 892 mm 23 1 4 591 mm Includes 3 4 20 mm Integ...
Страница 10: ...rly grounded electrical receptacles placed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are e...
Страница 11: ...5 models only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighte...
Страница 12: ...adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be ge...
Страница 13: ...hen hardware is installed When applying an integrated panel to a unit ensure that both sides are finished in order to prevent warping In some panel installations the panel may be visible through the g...
Страница 14: ...use of bar clamps to secure the panel to the door drawer If using tape be certain the tape will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood pa...
Страница 15: ...move clamps from door drawer NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion 12 Starting at...
Страница 16: ...e removing the grille When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing...
Страница 17: ...ed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance...
Страница 18: ...ing conditions It is not designed for excessive force Do not use the door to move the unit in out of the cutout during installation If your unit is already undercounter it might need to be moved out f...
Страница 19: ...asket is not pinched on the hinge side of the door To align and adjust the door 1 Remove grille see GRILLE PLINTH INSTALLATION 2 Loosen do not remove top and bottom hinge screws 3 Align door squarely...
Страница 20: ...o holes where the hinge was removed Take care not to scratch cabinet 5 Remove it from the cabinet Repeat for cabinet base Prepare door for reinstallation 1 Rotate door 180 to reverse 2 Align the flat...
Страница 21: ...ly used when unit is not installed in surrounding cabinetry To install the kit 1 Remove grille see GRILLE PLINTH INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligni...
Страница 22: ...at the factory Initial startup requires no adjustments NOTICE U Line recommends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the f...
Страница 23: ...TROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door win...
Страница 24: ...ntain internal temperatures and set points View a full list of Star K certified U Line units at www star k org To enable Sabbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will...
Страница 25: ...o perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between the evaporat...
Страница 26: ...t by pulling out 3 Insert the shelves as follows 1 To move to a different position in the unit insert shelf at an angle approximately 15 20 over the rib in the side of the unit where you want to place...
Страница 27: ...ainless surfaces this includes glass tile and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always...
Страница 28: ...sonal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan place towels or...
Страница 29: ...necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the con...
Страница 30: ...it is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open...
Страница 31: ...s listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Condenser Fan Air...
Страница 32: ...r openings and the time the door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Digital Display Shows 1 16 or 99 A factory test mode may be ena...
Страница 33: ...r you can register on line at www u lineservice com 3 The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase a...
Страница 34: ...able warranty period 8 THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTIC...
Страница 35: ...PLUG NEUTRAL HOT RELAY EMBRACO COMPRESSOR GREEN or GREEN W YELLOW GROUND OVERLOAD CAP 1 10 CONTROL BOARD FUSE 16 8 9 1 6 1 10 5 TEST TERMINAL EVAP TEMP REF TEMP LIGHT DOOR SWITCH GREEN W YELLOW BLACK...
Страница 36: ...roduct equipped with a drain pump the drain pump must be returned along with the unit regardless of the drain pump manufacturer To complete the damage claim process for the customer please forward the...
Страница 37: ...dashes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may...
Страница 38: ...r U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original...
Страница 39: ...ge Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near...
Страница 40: ...ist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and...
Страница 41: ...ed Remedy Not Cooling Compressor overheating Verify proper air flow through condenser Is condenser clean Confirm condenser fan operation Confirm proper compressor operating voltage Use 19 Component Te...
Страница 42: ...ose the main control Power Fault If the unit does not or seems to not power on follow the flow chart below to help diagnose the issue Before beginning it is important to first verify the unit is not s...
Страница 43: ...onents have been ruled out as being faulty but the unit continues to have operating issues it is most likely due to a configuration error Configuration errors can be cleared by restoring the unit to i...
Страница 44: ...ormally Evaporator thermistor errors will be displayed in the error log Always assure that all thermistor connections are clean and dry Whenever opening a thermistor connection be sure to apply a fres...
Страница 45: ...emperature Navigates through service menu LED activated with button activation 4 Light Button Activates light for 3 hours on select models Used to select items in service menu LED activated with butto...
Страница 46: ...l will begin to flash When the degree symbol is flashing the unit will allow the use of the control for demonstrations The unit can be left in this mode indefinitely To exit this mode interrupt power...
Страница 47: ...light icon to enter and save change 14 Display error log Use up down to access and light bulb key to view 15 Clear error log Use up down to access and light bulb key to clear 16 View thermistor 1 dif...
Страница 48: ...odel 9 VIEW THERMISTOR 2 SET POINT MINUS OFFSET 10 Does not apply to this model 11 Does not apply to this model 12 DEFROST INTERVAL ADJUST 3 TO 24 HOURS This will adjust the interval between defrosts...
Страница 49: ...24 hours 23 COMPRESSOR RUNTIME BASED ON LAST CYCLE This will show the number of minutes the compressor has run in the prior cycle or current cycle if the compressor was running when service mode was e...
Страница 50: ...heit Celsius F C Defrost Duration Minutes 45 Next Defrost Hours 12 Thermistor Four OFFSET 0 Thermistor Three OFFSET 0 Thermistor Two OFFSET 0 Thermistor One OFFSET 7 Thermistor One Differential Up 1 T...
Страница 51: ...DURATION 0 TO 99 MINUTES UP DOWN TO SELECT LIGHT ICON TO ENTER AND SAVE CHANGE 14 DISPLAY ERROR LOG USE UP DOWN TO ACCESS AND LIGHT BULB KEY TO VIEW 15 CLEAR ERROR LOG USE UP DOWN TO ACCESS AND LIGHT...
Страница 52: ...shorted E9 Door open error PI Pump Circuit open Programming the unit to correct model number 1 Unplug unit and install new board 2 Push and hold the hidden icon 3 Plug the unit in 4 Release the hidde...
Страница 53: ...nit has two thermistors Thermistor one is located along the right hand side wall inside of the unit and is used to maintain temperature within the unit Thermistor two is located on the back of the eva...
Страница 54: ...ION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Defrost These units are automatic cycle defrost unit will defrost itself when the control sensor is satisfied of internal temperatures Defros...