46 Maintenance
Dimension BST 1200es / SST 1200 es User Guide
After Each Build
Empty Purge Container
The black, plastic purge container is attached to the right side of
the modeling envelope rear wall (see
NOTE
A full purge container may impact part quality.
1. Remove the purge container by grasping it and pushing it
upward to release it from its three mounts.
2. Pull the container towards you and out of the chamber.
3. Empty the container and reinstall on 3 mounts.
500 Hour Maintenance
Clean Fan Filter
To clean the fan filter:
1. Locate the lower fan on the rear panel of Dimension and
remove the plastic frame (snaps on and off) that secures the
fan filter.
2. Clean the filter with soap and water, and blot it dry.
3. Reassemble.
CAUTION
When reinstalling the container, make
sure that it locks on all three mounts and
hangs flush with the chamber wall to
avoid damage.