C94-M8P - User Guide
UBX-15031066 - R06
Advance Information
Operation
Page 14 of 29
4
Operation
4.1
Base in operation
When the Base device is in normal operation, by enabling message UBX-NAV-STATUS, the Data View in u-center
shows “TIME” fix mode.
Figure 8: Data View shows “TIME” when Base is in FIXED mode
4.2
Rover in operation
When the Rover device is in normal operation, the Data View in u-center shows “FLOAT” or “FIXED” to indicate
the current operation mode.
Figure 9: Data View shows “FLOAT” or “FIXED” on Rover
Additionally, the message “UBX-NAV-RELPOSNED” in u-center shows more details about relative positions and
accuracies. For more information, refer to the
u-center User Guide
[4], the u-blox 8 /
u-blox M8 Receiver
Description including Protocol Specification
[1], and
Protocol Specification Addendum for HPG1.30
[5].