Installation and commissioning
● Connect all plugs as labelled to the control box .
● On the
TYPICAL 574
with the control unit
P40 ED
plug
1
of the adapter cable (see blow-up)
should be inserted in socket
X2.
The motor and the "external" plug of the synchronizer
should be connected to the "motor" plug.
● On the
TYPICAL 574
with the control unit
P44 PD-L
the synchronizer plug should be inser-
ted directly in socket
X7.
● Screw the earth cable from the sewing head and the main switch to earth point
A.
● Connect earth point
A
to earth point
B
with earth cable.
● Fasten the earth cable from plug
X1
to earth point
B.
8
.04
Connecting the safety sw itch
● Connect plug
1
of safety switch
2
as
shown in Fig.
8-09.
2
When the sewing head is til-
ted back, the safety switch pre-
vents the machine starting
when the main switch is on.
1
Fig. 8 -09
8
.05
Checking the start inhibitor function
● Switch the machine on at the main switch and tilt back the sewing head.
● The error message "Error
9"
must appear on the control panel.
● If the message does not appear, check the setting of safety switch
2.
● After the sewing head has been returned to the upright position, the machine is
ready for operation again.
61-113
27
Содержание TW1-571
Страница 1: ...TW1 571 574 591 POSTBED SEWING MACHINE INSTRUCTION MANUAL...
Страница 2: ......
Страница 4: ...This Instruction Manual is valid for all models and subclasses listed in the chapter Specifications...
Страница 50: ...Circuit diagrams 11 05 03 Version 18 06 07 91 191 524 95 Part 1 Circuit diagrams 91 191 524 95 48...
Страница 51: ...91 191 524 95 Part 2 Version 18 06 07 Circuit diagrams 49...
Страница 53: ...91 191 534 95 Part 1 11 05 05 Version 12 03 08 Circuit diagrams Circuit diagrams 91 191 534 95 51...
Страница 54: ...Circuit diagrams Version 12 03 08 91 191 534 95 Part 2 52...
Страница 57: ...Notes...