Carbon Monoxide Alarm 
869MHz

 

Caring for People 

 
 

 

 
_________________________________________________________________________

 

________________________________________________________________ 

 
 

 
 

 

 

  Doc No. FM0824 V1.04 Page 1   

 

 

 

 

 

 
 

 

 

Compatible with Reach IP and Advent XT2 

 

Complies with BS EN 50291-1 & 2:2010 + A1:2012  

 

Advanced electrochemical sensor technology 

 

10 year sealed for life Lithium battery (typical) 

 

Alarm sound level: 85dB(A) @ 3m 

 

Large central Test/Silence (

) button 

 

Operating Temperature: +4

o

C to +38

o

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Digital Heartbeat 

 

Weight: 193 grams 

 

Dimensions: 114mm x 94.5mm x 40mm  

 

Product Code: ZXT812 

 

 

How Carbon Monoxide can affect you 

Refer to the Manufacturer’s instruction booklet for full details on 

the symptoms associated with increasing degrees of exposure to 
Carbon Monoxide. 

DANGER:

 

Never ignore any alarm, further exposure can be fatal. 

Get medical help immediately for anyone suffering the effects of 
Carbon Monoxide poisoning (e.g. headaches or nausea).  

Contact your Gas supplier on their emergency number.  

Do not use the appliance again until it has been checked by a Gas 
Safe qualified engineer.   
 

Positioning

 

Carbon Monoxide (CO) alarms 

should be installed in every 

room containing a fuel-burning appliance and every 
sleeping room. 

When fitting in the same room as a fuel burning 

appliance the alarm should be at a horizontal distance between 1 
and 3m from the potential source, if the room has a sloped 
ceiling it should be at the high side of the room. If the alarm is 
wall mounted it should be at least 150mm below the ceiling and 
at a height greater than any door or window. If the alarm is 
ceiling mounted it should be at least 300mm away from any wall 
or light fitting. If fitted in sleeping rooms the alarm should be 
located close to the breathing zone of the occupants.  

Refer to the Manufacturer’s instruction booklet for more 

information on positioning.

 

 

Normal Operation

 

The green power light will flash once every 60 seconds to indicate 
normal operation. 

 

 
 

Alarm Condition

 

If Carbon Monoxide is detected the unit will repeatedly sound 4 
loud beeps and the red CO light will flash once every 5 seconds. 
Keep calm, turn off all fuel-burning appliances and open the doors 
and windows and evacuate the property.  
Do not re-enter the building until the alarm has stopped. 

 

Low Battery Condition

 

If the unit chirps every 60 seconds and the yellow warning light 
flashes at the same time, this indicates the battery is running low. 
The low battery condition will also be reported to the Alarm 
Receiving Centre (ARC) or the local Manager once a day.  
The telecare transceiver module also contains a battery - this is 
self-

tested once a day, if it’s low for 7 consecutive days a low 

battery condition will be reported once a week. The complete CO 
alarm should be replaced as soon as possible within 30 days. 

 

Sleep Easy Feature 

Low battery warnings often start when it is inconvenient to 
replace the alarm. You can silence the audible low battery chirp 
for a period of 8 hours by pressing the Test/

 button. After this 

period the audible chirp will start again. This process can be 
repeated up to 10 times. The alarm will still detect CO during this 
time, however it must be replaced within 30 days.  

 

Fault Condition

 

If the unit chirps every 60 seconds and the yellow warning light 
flashes 20-25 seconds after, this indicates a fault with the CO 
alarm and it should be replaced immediately.  

 

Out of Range Notification (Reach IP)

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed from 

an installation. Should the Reach IP be unable to detect a device’s 
heartbeat it will automatically generate a “radio out of range” 
notification. Firstly, investigate if there’s a genui

ne reason for the 

alert, if not, arrange for the peripheral device to be replaced 
immediately. 

The “Radio out of range timer” can be set from 30 

hours to 99999 hours in Pulse CMP. “Radio supervision” can be 

disabled by unchecking the tick box associated with each 
peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the CO alarm once every month. 
Clean once every 3 months using a vacuum cleaner fitted with 
the soft brush attachment. Do not use solvents or cleaners on 
the CO alarm, the unit can be wiped with a damp cloth. 

 

Disposal

 

Waste electrical products should not be disposed of with normal 
household waste. The CO alarm is ideally suited for disposal 
within the waste electronic and electrical equipment (WEEE) 
recycling scheme. Please recycle where facilities exist.  
Check with your local authority or contact your supplier for 
recycling/disposal advice. 

 

Warning

 

The CO alarm contains a powerful Lithium battery. If tampered 
with the battery may be damaged and create a fire hazard. No 
attempt should be made to open the case or remove the battery. 
Do not incinerate. 