Tynetec ZXT478 Скачать руководство пользователя страница 1

Doc

 

No.

 

FM0626

 

issue

 

B

 

Page

 

1

  

169MHz

 

Telecare

 

Devices

 

Property

 

Exit

 

Sensor

 

__________________________________________________________________________________________________________

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatible

 

with

 

Reach

 

at

home

 

alarms

 

and

  

Altec

 

Response

 

local

 

carer

 

alarms

 

 

PIR

 

detector,

 

wall

 

bracket,

 

door

 

contact

 

&

 

magnetic

 

exit

 

fob

 

 

Adjustable

 

alarm

 

delay:

 

10

 

seconds

 

to

 

90

 

minutes

 

 

User

 

replaceable

 

9V

 

PP3

 

Lithium

 

battery

 

 

Low

 

battery

 

warning

 

 

PIR

 

dimensions:

 

114mm

 

x

 

70mm

 

x

 

76mm

 

(HxWxD)

 

 

PIR

 

weight

 

inc

 

battery

 

&

 

bracket:

 

280

 

grams

 

 

Product

 

Code:

 

ZXT478

 

 

 

 

 

 

 

 

 

What

 

can

 

the

 

Property

 

Exit

 

Sensor

 

be

 

used

 

for?

 

 

The

 

property

 

exit

 

sensor

 

is

 

used

 

to

 

raise

 

an

 

alarm

 

if

 

a

 

resident

 

leaves

 

their

 

home

 

or

 

if

 

they

 

accidently

 

leave

 

their

 

front

 

door

 

open.

 

It

 

works

 

by

 

monitoring

 

a

 

combination

 

of

 

the

 

front

 

door

 

being

 

opened/closed

 

and

 

movement

 

in

 

the

 

hallway.

  

 

Scenario

 

1:

 

if

 

the

 

door

 

is

 

opened

 

and

 

closed

 

followed

 

by

 

movement

 

in

 

the

 

hallway

 

it

 

is

 

assumed

 

a

 

visitor

 

has

 

entered

 

or

 

the

 

resident

 

has

 

answered

 

a

 

call

 

at

 

the

 

door

 

and

 

no

 

alarm

 

is

 

raised.

 

 

Scenario

 

2:

 

if

 

the

 

door

 

is

 

opened

 

and

 

closed

 

followed

 

by

 

no

 

movement

 

in

 

the

 

hallway

 

it

 

is

 

assumed

 

the

 

resident

 

has

 

left

 

their

 

home

 

and

 

a

 

door

 

exit

 

alarm

 

will

 

be

 

raised.

 

 

Scenario

 

3:

 

if

 

the

 

door

 

is

 

opened

 

and

 

left

 

open

 

followed

 

by

 

no

 

movement

 

in

 

the

 

hallway

 

it

 

is

 

assumed

 

the

 

resident

 

has

 

left

 

their

 

home

 

and

 

a

 

door

 

exit

 

alarm

 

will

 

be

 

raised.

  

 

Scenario

 

4:

 

if

 

the

 

door

 

is

 

opened

 

and

 

left

 

open

 

followed

 

by

 

movement

 

in

 

the

 

hallway

 

it

 

is

 

assumed

 

the

 

resident

 

has

 

left

 

their

 

door

 

open

 

and

 

a

 

door

 

open

 

alarm

 

will

 

be

 

raised.

  

  

For

 

a

 

visitor

 

to

 

leave

 

without

 

raising

 

an

 

alarm

 

they

 

must

 

first

 

open

 

the

 

door

 

then

 

swipe

 

the

 

PIR

 

down

 

the

 

right

 

hand

 

side

 

with

 

the

 

magnetic

 

fob

 

then

 

close

 

the

 

door

 

behind

 

them.

 

 

 

 

The

 

PIR

 

only

 

begins

 

to

 

look

 

for

 

activity

 

AFTER

 

the

 

door

 

is

 

opened

 ‐ 

the

 

time

 

period

 

the

 

PIR

 

is

 

active

 

for

 

is

 

adjustable

 

from

 

10

 

seconds

 

to

 

90

 

minutes.

 

If

 

the

 

PIR

 

is

 

not

 

activated

 

during

 

this

 

period

 

an

 

alarm

 

call

 

is

 

raised.

 

 

 

Where

 

should

 

the

 

Property

 

Exit

 

Sensor

 

be

 

fitted?

 

 

Use

 

the

 

wall

 

mounting

 

bracket

 

provided

 

and

 

fix

 

the

 

PIR

 

approx

 

2

 

metres

 

high

 

and

 

approx

 

1

 

metre

 

inside

 

the

 

front

 

door.

  

The

 

PIR

 

should

 

be

 

adjusted

 

to

 

point

 

down

 

the

 

hallway

 

AWAY

 

from

 

the

 

door,

 

see

 

below;

 

 
 
 
 
 
 
 
 
 
 
 
 

 

If

 

there

 

are

 

pets

 

in

 

the

 

home

 

the

 

PIR

 

should

 

be

 

mounted

 

at

 

low

 

level

 

(1m)

 

and

 

the

 

PCB

 

should

 

be

 

set

 

to

 

the

 

PET

 

ALLEY

 

position.

 

The

 

door

 

contact

 

should

 

be

 

fitted

 

on

 

the

 

front

 

door

 

and

 

wired

 

back

 

to

 

the

 

PIR

 

using

 

the

 

cable

 

provided.

 

 

  

 

 

Avoid

 

placing

 

items

 

in

 

front

 

of

 

the

 

PIR

 

detector

 

which

 

may

 

restrict

 

its

 

field

 

of

 

view

 

  

Do

 

not

 

expose

 

the

 

PIR

 

detector

 

to

 

wind,

 

air

  

  

conditioning

 

or

 

heating

 

 

Do

 

not

 

expose

 

the

 

PIR

 

detector

 

to

 

direct

 

sunlight

  

or

 

powerful

 

lights

  

 

 

  

Do

 

not

 

drop

 

the

 

PIR

 

detector

 

or

 

expose

 

to

 

high

  

  

vibration

 

or

 

shock

 

 

Do

 

not

 

expose

 

the

 

PIR

 

detector

 

to

 

rapid

 

variation

  

in

 

temperature

 

 

 

 
 

 

Tynetec and

 

Aidcall

 

are business

 

units

 

of

 

Legrand

 

Electric

 

Ltd

Unit

 

10

 

Cowley

 

Road,

 

Blyth

 

Riverside

 

Business

 

Park,

 

Blyth

 

Northumberland,

 

NE24

 

5TF.

 

Tel:

 

01670

 

352

 

371

 

Fax:

 

01670

 

362

 

807

 

Email:

 

[email protected]

  

Web

:

 

www.tynetec.co.uk

Отзывы: