5
Setting humidity (Combi heaters)
Use the function selection buttons (F) to select humidity setting. Use the - and + buttons to then select
humidity setting 0-10. 0 (Off) is selected by pressing < while humidity is set to 1. The LED scale indica
-
tes the time steam tank is On and Off. During the heating up period of the sauna, the amount of steam
produced depends on the set temperature. When the temperature setting is 1-5 steam will be produced
according to the set humidity (see table below, steam priority). When the temperature setting is 6-10
steam production will not start untill the temperature has reached its target (temperature priority).
Door Switch
Door switch is not used in North America.
Using an external switch
An external switch for starting/stopping the heater not mounted on the control panel can be connected.
A door contact must be installed. See wiring diagram supplied with external switch for connection. We
recommend using Tylö’s external switch (item number 90908045). This also provides indication via LED
of whether the sauna is on, programmed for delayed start and error status for a magnetic door contact
(if fitted)
A continuous light indicates that the heater is on.
Slow flash indicates that the heater is programmed for delayed start.
Rapid flash indicates that the door has been opened when the heater is programmed for delayed start.
Alternatively, the door has been open for more than 5 minutes during operation or has been opened
after the heater has been switched off. The control panel will then require resetting.
Set temperature (approx. value, °C)
Max temperatur
1
2
3
4
5
6
7
8
9
10
90 °C
60
63
67
70
73
77
80
83
87
90
194 °F
140
145
153
158
163
171
176
181
189
194
Set humidity
Steam priority
Temperature priority
1
2
3
4
5
6
7
8
9
10
Steam on (min:sek) 01:45 02:00
02:17
02:33
02:47
03:05 03:20 03:35 03:50
always on
Steam off (min:sek)
02:23 02:08 01:51 01:35 01:21 01:03 00:48 00:33 00:18
never off