11
CONNECTION/WIRING DIAGRAM
400-415 V 3N~/3~
230-240 V 3~
230-240 V~
Output kW
Amperage
amp
Wiring area
mm²
Amperage
amp
Wiring area
mm²
Amperage
amp
Wiring area
mm²
10.5
16
2.5
28
10
48*
16*
Figure 11: Wiring diagram
1. NTC Sensor
2. External switch
3. Door switch
4. SEC/NTC Sensor (option)
5. RS485 control panels
6. RS485 control panels
7. RS485 control panels
8. RS485 control panels
9. Heater
10. Terminal for connection of electrical
cable
11. Control panel (connect to positions 5-8)
12. Sensor (connect to NTC position 1)
13. Lighting/terminal for connection of lighting
14. Door contact (option)
15. External switch (option)
9
13
14
15
11
12
1
2
3
4
5
6
7
8
11
10
13
RJ10 4P4C
2 x 1.5 mm
2
3 x 1.5 mm
2
RJ10 4P4C
RJ10 4P4C
RJ10 4P4C
B
B
40
230V~
Max 6Amp
41
10.5 kW
10.5 kW
10.5 kW
10
10.5
16
32
10
28
16*
48*
* 10.5kW is not approved for 230V~ in Europe.