TYCON POWER SYSTEM 

 

 

   

TYCON TP-SSW5(-NC)

 

5 port PoE Endspan (Switch) 

USER’S MANUAL 

 

 

 

 

Содержание TP-SSW5

Страница 1: ...TYCON POWER SYSTEM TYCON TP SSW5 NC 5 port PoE Endspan Switch USER S MANUAL ...

Страница 2: ...User s Manual TYCON TP SSW5 NC TYCON POWER SYSTEMS 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port Wiring PD Port Wiring 3 Technical Specification 3 3 3 5 6 7 8 ...

Страница 3: ...iance with IEEE802 3af at standard to deliver both of Ethernet data and DC power through the traditional UTP or STP cable to the PD This manual will help you install and maintain the PoE switch Installation of the PoE switch is very easy and you will begin to operate as soon as you are powered up 2 Hardware Description LED Indicator There are 11 LEDs on the PoE switch to indicate the power and ope...

Страница 4: ...r current 2A per port the indicator is used on current model only Off No power in DC input SWITCH LED the right indicator on RJ45 LED STATUS Description P1 P4 UP LINK Link Act Green A network device is detected but no communication activity is detected Blinking 43ms This port is transmitting to or receiving package from another device at 100Mbps Blinking 120ms This port is transmitting to or recei...

Страница 5: ...DC TP SSW5 For 802 3af at model operation make sure your power supply may offer at least 75W for 4x 802 3af PoE port or 150W for 4x 802 3at PoE port For current model operation please make sure the output current don t over 2A per port For 802 3af at operation the input voltage must be in the range of 44 to 57 VDC Otherwise the PoEswitch will function only as an Ethernet switch but will not provid...

Страница 6: ...ossover autosense of the speed and duplex for 10Base T or 100Base TX connections Automatic MDI MDI X crossover allows you to connect to other devices switches hubs or workstations etc without regard to using straight through or crossover cabling Port 1 to port 4 also provides Power over Ethernet function which delivers DC power through the spare pairs pair 4 5 and pair7 8 to the PD The following t...

Страница 7: ... port and connect the other side to your attached device The green Link Act LED will light up when the cable is correctly connected Refer to the LED Indicator section for descriptions of each LED indicator If a port LED is off go back and check for connectivity problems between that port and the network device it is connected to The maximum cable length for 10 100BaseT with Cat5 twisted pair cable...

Страница 8: ...ort NegativenVport 7 Negative Vport 8 Negative Vport Be sure the twisted pair cable is bound with the standard RJ 45 pin especially the pin 4 5 7 and 8 If the RJ 45 is bound with the wrong pin number PoE switch will not recognize the PD and won t deliver DC power to PD The yellow PoE LED will light up when the cable is correctly connected Refer to the LED Indicator section for descriptions of each...

Страница 9: ... PoE power IEEE802 3af 16 8W IEEE802 3at 35W Current limited 2A PoE disconnect mode DC disconnect PoE auto detection IEEE802 3af IEEE802 3at 2 event classification signaling PoE protection Over temperature over current over under voltage LEDs Link Activity Green ON Green Blinking every 43ms 100Mbps Green Blinking every 120ms 10Mbps PoE Yellow On PoE output POWER Green normal Red alarm Power input ...

Страница 10: ...r s Manual TYCON TP SSW5 NC TYCON POWER SYSTEMS 10 Operating temperature 40 85 Operation humidity 90 relative humidity non condensing Storage temperature 55 105 Dimension 40mm H x116mm W x90mm D main body ...