D-304286 SD-304C PG2 Installation Instructions 

1

 

 

 

 

Installation  Instructions

 

SD-304C PG2 

PowerG, Wireless Shock and Contact detector 
with Wired Input

 

1. INTRODUCTION 

The  SD- 304C  PG2 is a wireless  PowerG innovative shock detector with optional magnetic contact and 
auxiliary  input interf acing with  all PowerMaster  control panels, version 16  or higher.  The  SD-304C PG2 f its 
windows, doors, walls or roofs and is ideal f or residential or commercial installations. It detects and analyzes 
gross attacks or a series of  low level shocks (up to 10 low level shoc ks within 30 seconds) and provides early 
warning of  any attempt of intrusion before a burglar actually breaks -in. 
The  detector incorporates: 

  A shock / vibration piezoelectric sensor.

 

  Optional  reed  switch  (with  optional  anti-mask  sensor  to  prevent  attempts  at  disabling  it  with  an  extra 

magnet).

 

⚫ 

Optional auxiliary  input to use with  installer supplied contacts or other  wired devices. 

Installer  added-value f eatures:

 

  Digital display enables f ast and easy shock level adjustment

 

  Full  remote  conf iguration  f rom  Po werMaster  control  panel  or  Monitoring  Station  saves  the  need  to 

physically access the shock detector f or conf iguration  

  Remote view  of : Low Battery, f ront and back Tamper,  Supervision 

  An  LED  lights  whenever  alarm  or  tamper  events are reported (the LED does not light while a supervision 

message is being transmitted ). 

 

A.

 Transmission  LED  

B.

 Magnet 

Figure 1:  External  View 

2. INSTALLATION 

2.1 Mounting 

 

A.

 Auxiliary input

 

terminals

 

B. 

Back tamper  switch 

(behind P.C. board)  

C.

 Battery clips 

D. 

Break-away  segment 

(f or back tamper)

 

E. 

Digital display 

F. 

Front tamper  switch 

G. 

Enroll button 

H.

 LEDs indication  

I.

  Reed  switch 

J. 

Up and down buttons 

Figure 2. Base with  P.C. Board  Removed

 

Ref er to the Shock Detection Radius, in the Specif ications section, according to the surf ace material  used. Install  the device in a location where  a 
strong shock impact is expected. The  unit should be mounted on a f lat surf ace and f irmly f ixed using both mounting screws. 
For magnetic contact detection, it is highly recommended to attach the detector to the door or window on the  f ixed f rame and the magnet  to the 
movable part (door or window).

 

For optimal magnetic sensor activity and better security it is recommended to apply the magnet as close as 

possible to the 

detector’s marked side.

 

Note:  Once  the  cover  is  removed,  a  tamper  message  is  transmitted  to  the  control panel. Subsequent removal of  the battery prevents transmission 
of "TAMPER RESTORE", leaving  the  detector in permanent  alert. To avoid  this, press the  tamper  switch whil e  you remove  the battery. 
Caution! 

Risk of  explosion if  battery is replaced by an incorrect type. Dispose of used battery according to manuf acturer's instructions.

 

Attention!  The  unit  has  a  back  tamper  switch  (optional)  under  the  PCB.  As  long  as   the  PCB  is  seated  firmly  within  the  base, the switch lever will 
be  pressed  against  a  special  break-away  base  segment  that  is  loosely  connected  to  the  base  (Figure  2).  Be  sure  to  fasten  the  break-away 
segment  to  the  wall.  
If  the  detector  unit  is  forcibly  removed  from  the  wall,  this segment will break away from the base, causing the tamper switch 
to open