COLD
< 19°C
(<66°F)*
Define whether or not the control panel reports a
COLD
alert when the temperature drops below the
threshold
value
for at least the duration specified in the
alert delay
value. The alert restore occurs when the temperature rises 1°C or
1.8°F above the
threshold
value for at least the duration of the
restore delay
value.
Note:
The default
threshold
value for
COLD
is 19°C or 66°F. The default
alert delay
value and default
restore
delay
value is 10 minutes.
Optional settings: See Table 3.
FREEZING
< 7°C
(<45°F)*
Define whether or not the control panel reports a
FREEZING
alert when the temperature drops below the
threshold
value for at least the duration specified in the
alert delay
value. The alert restore occurs when the temperature rises
1°C or 1.8°F above the
threshold
value for at least the duration of the
restore delay
value.
Note:
The default
threshold
value for
FREEZING
is 7°C or 45°F. The default
alert delay
value and default
restore
delay
value is 10 minutes.
Optional settings: See Table 3.
Disarm activity
Define the length of time that the sensor continues to detect motion during the disarm process.
Optional settings:
NOT Active
(default),
YES – no delay
,
YES + 5 s delay
,
YES + 15 s delay
,
YES + 30 s delay
,
YES + 1 min
,
YES + 2 min
,
YES + 5 min
,
YES + 10 min
,
YES + 20 min
,
YES + 60 min
Notes:
l
To generate an alarm or restore transmission, the temperature must pass beyond the
threshold
value for the required duration.
l
The user can give access to the installer to remotely enable or disable the indication LED.
5.2. Configuring the temperature alerts
Configure each of the four temperature alerts:
VERY HOT
,
COLD
,
FREEZING
, and
FREEZER
. Table 3 describes the temperature configuration
setting options.
Table 3: Temperature configuration settings
Option
Configuring instructions
Threshold
Displays the last saved
threshold
value. To change the default value, click the back or next button to decrease or increase the value
and click
OK
.
Disable
/
Enable
Defines whether or not the panel will report an alert or not.
Alert delay
Define the amount of time to pass before an alert is reported when the temperature exceeds the defined default duration.
The
alert delay
time values are:
Immediately
,
1 min
,
2 min
,
10 min
,
15 min
,
20 min
,
30 min
Restore
delay
Defines the amount of time to pass before a restoration alert is reported when the temperature returns below the
threshold
value.
The
restore delay
time values are:
Immediately
,
1 min
,
2 min
,
10 min
,
15 min
,
20 min
,
30 min
5.3. Setting the detector range
From the PowerMaster panel installer menu, select
02:ZONES/DEVICES
and follow the menu path displayed in Table 4 to configure the device
detection range.
Note:
If you enroll the MP-902 PG2 in PowerMaster panels with version 19.4 or lower, the detector enrolls as an outdoor PIR motion detector. The
device enrolls in the panel with the device ID,
130-xxxx
, and the name,
Motion Outd.
.
Table 4: Setting the detector range
Panel
Device type
Menu path and options
Range
V20.2 and higher
MP-902 PG2
S.OutCurtain
ID: 129-xxxx
>02:ZONES/ DEVICES>
>DEVICE SETTINGS>
>PIR RANGE>
Long
Medium
Short
8 m
5 m
3 m
V19.4 and lower
TOWER-20AM
Motion Outd.
ID: 130-xxxx
>02:ZONES/DEVICES>
>DEVICE SETTINGS>
>PIR SENSITIVITY>
High
Low
One region
8 m
3 m
8 m
Notes:
The range refers to Number 2 in Figure 11.
The
symbol signifies the detector point of view and the beginning of the PIR curtain.
D-307164 MP-902 PG2 Installation instructions
4