Tyco MP-902 PG2 Скачать руководство пользователя страница 4

COLD

< 19°C
(<66°F)*

Define whether or not the control panel reports a

COLD

alert when the temperature drops below the

threshold

value

for at least the duration specified in the

alert delay

value. The alert restore occurs when the temperature rises 1°C or

1.8°F above the

threshold

value for at least the duration of the

restore delay

value.

Note:

The default

threshold

value for

COLD

is 19°C or 66°F. The default

alert delay

value and default

restore

delay

value is 10 minutes.

Optional settings: See Table 3.

FREEZING

< 7°C
(<45°F)*

Define whether or not the control panel reports a

FREEZING

alert when the temperature drops below the

threshold

value for at least the duration specified in the

alert delay

value. The alert restore occurs when the temperature rises

1°C or 1.8°F above the

threshold

value for at least the duration of the

restore delay

value.

Note:

The default

threshold

value for

FREEZING

is 7°C or 45°F. The default

alert delay

value and default

restore

delay

value is 10 minutes.

Optional settings: See Table 3.

Disarm activity

Define the length of time that the sensor continues to detect motion during the disarm process.
Optional settings:

NOT Active

(default),

YES – no delay

,

YES + 5 s delay

,

YES + 15 s delay

,

YES + 30 s delay

,

YES + 1 min

,

YES + 2 min

,

YES + 5 min

,

YES + 10 min

,

YES + 20 min

,

YES + 60 min

Notes:

l

To generate an alarm or restore transmission, the temperature must pass beyond the

threshold

value for the required duration.

l

The user can give access to the installer to remotely enable or disable the indication LED.

5.2. Configuring the temperature alerts

Configure each of the four temperature alerts:

VERY HOT

,

COLD

,

FREEZING

, and

FREEZER

. Table 3 describes the temperature configuration

setting options.

Table 3: Temperature configuration settings

Option

Configuring instructions

Threshold

Displays the last saved

threshold

value. To change the default value, click the back or next button to decrease or increase the value

and click

OK

.

Disable

/

Enable

Defines whether or not the panel will report an alert or not.

Alert delay

Define the amount of time to pass before an alert is reported when the temperature exceeds the defined default duration.
The

alert delay

time values are:

Immediately

,

1 min

,

2 min

,

10 min

,

15 min

,

20 min

,

30 min

Restore
delay

Defines the amount of time to pass before a restoration alert is reported when the temperature returns below the

threshold

value.

The

restore delay

time values are:

Immediately

,

1 min

,

2 min

,

10 min

,

15 min

,

20 min

,

30 min

5.3. Setting the detector range

From the PowerMaster panel installer menu, select

02:ZONES/DEVICES

and follow the menu path displayed in Table 4 to configure the device

detection range.

Note:

 If you enroll the MP-902 PG2 in PowerMaster panels with version 19.4 or lower, the detector enrolls as an outdoor PIR motion detector. The

device enrolls in the panel with the device ID,

130-xxxx

, and the name,

Motion Outd.

.

Table 4: Setting the detector range

Panel

Device type

Menu path and options

Range

V20.2 and higher

MP-902 PG2

S.OutCurtain

ID: 129-xxxx

>02:ZONES/ DEVICES>

>DEVICE SETTINGS>

>PIR RANGE>

Long

Medium

Short

8 m

5 m

3 m

V19.4 and lower

TOWER-20AM

Motion Outd.

ID: 130-xxxx

>02:ZONES/DEVICES>

>DEVICE SETTINGS>

>PIR SENSITIVITY>

High

Low

One region

8 m

3 m

8 m

Notes:

The range refers to Number 2 in Figure 11.
The

symbol signifies the detector point of view and the beginning of the PIR curtain.

D-307164 MP-902 PG2 Installation instructions

4

Содержание MP-902 PG2

Страница 1: ... 902 PG2 Before you install the device consider the following points l Install the MP 902 PG2 according to the Standard for Installation and Classification of Burglar and Holdup Alarm Systems UL 681 l Mount the detector so that the expected movement of the intruder will cross the PIR beam l Mount the device on a vertical surface and as straight as possible l Mount the device upright See Figure 2 l...

Страница 2: ...et to the mounting surface with screws See Figure 6 5 Insert the batteries into the detector and close the battery cover For more information see Inserting or replacing the batteries 6 Insert the top of the detector into the bracket As you insert the detector choose a slot in the bracket that positions the detector to cover the area that requires protection See Figure 7 and Figure 8 Note When you ...

Страница 3: ...ation instructions as described in Table 2 Table 2 Modifying the device Option Configuring instructions Alarm LED Activate or deactivate the alarm LED indication Optional settings LED ON default and LED OFF PIR range Select one of the three ranges according to your installation preference See Setting the detector range Outdoor anti mask Enable or disable the outdoor anti masking feature Optional s...

Страница 4: ...erts VERY HOT COLD FREEZING and FREEZER Table 3 describes the temperature configuration setting options Table 3 Temperature configuration settings Option Configuring instructions Threshold Displays the last saved threshold value To change the default value click the back or next button to decrease or increase the value and click OK Disable Enable Defines whether or not the panel will report an ale...

Страница 5: ... old batteries and insert the batteries with the and symbols matching the illustration found in the battery compartment See Number 2 in Figure 15 4 Optional To activate the batteries of a new device pull the battery tab while holding the batteries in place with your thumb See Figure 16 5 To close the battery compartment insert the bottom section of the battery cover first and then press and hold t...

Страница 6: ...d do not expect other pets or rodents to enter the protected area set the pet immunity selector to Setting 4 and mount the detector at a height of 1 6 m 5 25 ft to 2 m 6 56 ft The best mounting height for this setting is 2 m or 6 56 ft l If you have a small pet that weighs less than 3 kg or 6 6 lb or if there are rodents in the area set the pet immunity selector to Setting 2 and mount the detector...

Страница 7: ...llation guide l The MP 902 PG2 can be configured to detect movement with the following settings Left to right Right to left and Both For more information see the alarm direction setting in Modifying the device Table 5 Walk test signal strength indication LED response Reception 3 Green blinks Strong 3 Orange blinks Good 3 Red blinks Poor No blinks No communication 9 LED operation Table 6 provides t...

Страница 8: ...Pet configurations l Setting 1 Pet 18 kg or 40 lbs default l Setting 2 Small pet 3 kg or 6 6 lb or rodents l Setting 3 No function l Setting 4 No pet WIRELESS Frequency Europe and rest of world 433 434 MHz 868 869 MHz USA and Canada 912 919 MHz Note Only devices in frequency band 915 MHz are UL ULC listed Max Tx power 10 dBm 433 MHz 14 dBm 868 MHz Communication protocol PowerG Supervision Signals ...

Страница 9: ...urs de son fonctionnement normal Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resi...

Отзывы: