D-306042 WK160 

User’s Guide

 

3.4 Bypassing Zones 

A zone can by bypassed by pressing the 

 key until the zone number is shown on the zone # 

display (marked "4" in the "Icon and Key Indications" Figure) followed by the 

 

key. 

Notes: 

1.

 

Zone bypassing on the WK160 unit can be operated only if Bypass was enabled via the 

control panel (see WP8010/30 Installer Guide, section 3.5.2 "Configuring 

Arming/Disarming and Exit/Entry Procedures"). 

2. For UL Listed product, manual bypass must be enabled.  

3.5 Controlling Home Automation Devices 

To configure the PGM and X-10 output functions, see the corresponding sections of the 
control panel’s Installer Guide (“OUTPUTS” menu) and User Guide (“SCHEDULER” menu). 

Step 

X-10 device ON 

PGM device ON 

X-10 or PGM 

device OFF 

X-10 or  PGM 

device TOGGLE 

  (~2sec) 

 

 

 

 

[

P0

 

to P9

]

 

 

[

00

 

to 99

]

 

 

 

[PGM

 

 P0

 

to 

P9

] or [X-10

 01 

to 99

]

 

 

[PGM

 

 P0

 

to 

P9

] or [X-10

 01 

to 99

]

 

 

 

 

 

Notes: 

1. Long press (more than 2 sec.) of the 

 button initiates the X-10 function and the 

PGM/X-10 display (marked "4" in the "Icon and Key Indications" Figure) will read "01". 

Short press of the 

 button initiates the PGM function and the PGM/X-10 display will 

read "P0" with the 

 key. This number is incremented by 1 upon each press of the 

 

key. 

2. 

X-10/PGM not to be enabled in UL Listed Product.

3. 

Automation not to be enabled in UL Listed Product.

 

Содержание DSC WK160

Страница 1: ...ng Options 4 2 4 Enrolling the WK160 6 2 5 Configuring the WK160 Parameters 6 2 6 Enrolling Proximity Tags 8 3 USING THE TOUCH SCREEN KEYPROX 9 3 1 Arming and Disarming the System 9 3 2 Initiating Ala...

Страница 2: ...e WK160 can be wall mounted using the supplied bracket or be used as a portable unit For compliance with various international standards the WK160 is equipped with two tamper switches that can be defi...

Страница 3: ...incorrect type Dispose of used battery according to manufacturer s instructions Figure 1 Battery Insertion Insert two 1 5V batteries in each slot while ensuring battery polarity 2 2 Closing Battery C...

Страница 4: ...Mounting part b A Tamper B DC Power Connection 2 3 Wall Mounting Options The WK160 unit mounting options are illustrated in the following drawings Wall Mounting Figure 4a Wall Mounting 1 Drill 3 moun...

Страница 5: ...Mounting with External Electrical Connector Figure 4b Wall Mounting with External Electrical Connector 1 Secure bracket with 2 screws as shown in the two drawings above 2 Attach the unit to the bracke...

Страница 6: ...ready enrolled you can configure the WK160 parameters via the Modify Devices option see Step 2 2 5 Configuring the WK160 Parameters Enter the main menu in the WP8010 30 control panel choose the number...

Страница 7: ...Note For UL Listed product set to ON Define the volume level of the sounder Option settings Medium default Maximum and Minimum Note For UL Listed product the sounder cannot be used as the only annunci...

Страница 8: ...h the WP8010 30 control panel as described in the corresponding section of the control panel s User or Installer Guide Each proximity tag corresponds to its User Code Therefore be sure that a correspo...

Страница 9: ...enabled 2 sec Optional 4 INSTANT After arming HOME AWAY 5 7 LATCHKEY After arming AWAY 6 7 Notes 1 If Partition is disabled at the control panel skip Step 1 2 If Partition is enabled at the control p...

Страница 10: ...conds the WK160 sends the command Fire alarm 2 sec See section 3 3 Panic alarm 2 sec See section 3 3 When pressing the Fire and Emergency icons together the WK160 starts beeping After pressing the but...

Страница 11: ...on indication is displayed concurrently with the second partition key LED and then the third partition indication is similarly displayed General Indications The Ready Not Ready Alarm Memory Trouble an...

Страница 12: ...ion system has an active trouble status that needs to be reviewed and cleared 3 AC failure Communication failure WK160 is out of range of the control panel or did not get an acknowledge signal of a co...

Страница 13: ...s that are assigned to a Partition press the desired Partition number followed by the key Upon each press of the key the next zone number assigned to the pressed Partition number appears on the Zone d...

Страница 14: ...X 10 output functions see the corresponding sections of the control panel s Installer Guide OUTPUTS menu and User Guide SCHEDULER menu Step X 10 device ON PGM device ON X 10 or PGM device OFF X 10 or...

Страница 15: ...Low Battery Threshold 3 8 V Power source optional 5 12VDC Back light Blue white or black white Operating Temperature 0 C to 55 C 32 F to 131 F Note For UL Listed product the ambient temperature is 32...

Страница 16: ...operation The antennas used for this product must not be co located or operated in conjunction with any other antenna or transmitter The portable device version complies with FCC and IC RF radiation...

Страница 17: ...ge mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment Digital Security Controls DSC warrants that for a period of 12 months from the date...

Страница 18: ...18 D 306042 WK160 User s Guide 2016 Tyco International Ltd and its Respective Companies All Rights Reserved Toronto Canada www dsc com Printed in Israel D 306042 Rev 01 02 16...

Отзывы: