2.0 Introduction
- 9 -
2.1.3 Description
The basic configuration consists of one 19" rack mounted chassis comprising the following:
l
SG-MLRF5 - metal rack of the SG-System 5 with SG-MP5
l
SG-PSU5-600 - 600W power supply unit provides power to all modules of the system
l
SG-CPM5 - central processing module controls all communication to and from receiver modules and printers
l
SG-UIB5 - touch screen user interface
l
SG-DRL5-IP - Internet protocol line card
l
SG-DRL5-IP PAD - paddle card for SG-DRL5-IP provides network connection
l
SG-MLRF5-RM – Rack mount rails
l
SG-S5LFANTR – Line card fan tray
l
SG-S5CFANTR – SG-CPM5 fan tray
l
SG-S5SERCAB – Y cable for serial connection to the SG-CPM5 for automation/printer
l
SG_SYS5MEM4 – Removable EMMC memory
l
SG_SYS5DDR31 – DDR3 RAM
l
SG-CPM5BATT - SG-CPM5 real time clock battery
2.1.4 Specifications
Depth:
27.5" (69.85 cm)
Width:
19"
(48.26 cm)
Height:
7"
(17.78 cm)
Required Rack Space:
4U
Dimensions
SG-System 5 UL Electrical:
Input Voltage:
100-240 VAC, 50/60Hz.
Input Current:
8A max (RMS) @ 100VAC
Backup Power Supply:
External UPS (not supplied)
In a two SG-CPM5 configuration, a redundant SG-PSU5 can be inserted in the second slot. In the
event of a SG-PSU5 failure, the redundant SG-PSU5 automatically assumes operation. These
modules are hot swappable (can be removed/replaced while the system is in operation) if a
working, redundant SG-PSU5 is installed.
Environmental:
Temperature:
0-49°C (32 - 120°F)
Humidity:
93%RH, Non-Condensing
Accounts:
ULC Line Security Levels:
A1-A4 (active channels) or P1-P3 (passive channels)
Printers (UL/ULC Listed Installations):
Serial:
Seiko DPU-414
DACT Compatible communication formats (ULC Passive channels):
SIA, CID
Encryption:
AES 128 bit
2.2 System Features
2.2.1 SG-System 5
l
Reduced size of 4U in height for improved receiver room logistics management
l
CMS access to visual verification files through SG-Systems Console
l
Upgradeable through the SG-Systems Console
l
Enhanced hardware diagnostics via SG-Systems Console
l
Static IP for programming of network protocols
l
Real time system status via intuitive user touchscreen interface
l
Supports visual verification features for DSC PowerSeries Neo
l
Monitor up to 1,474,560 IP communicators (Cellular or Ethernet) with up to 24 IP line cards
l
Line card capacity starting at 4,094 IP accounts, upgradable up to 61,440 via licenses
l
Standard line card capacity of 512 visual verification, 512 supervised IP accounts, and 3070 unsupervised
l
Upgradeable memory to handle extensive future IP account capacity
S
G
-S
ys
te
m
5
O
pe
ra
ti
ng
M
anua
l
Содержание SG-System 5
Страница 68: ...6 0 Options 68 Automation Mode Diagrams FIGURE 6 1 Flow Diagram for Loop Mode 0 SG System 5 Operating Manual ...
Страница 69: ...6 0 Options 69 FIGURE 6 2 Flow Diagram for Fallback Mode 1 SG System 5 Operating Manual ...
Страница 70: ...6 0 Options 70 FIGURE 6 3 Flow Diagram for All Mode 2 SG System 5 Operating Manual ...
Страница 71: ...6 0 Options 71 FIGURE 6 4 Flow Diagram for IP Fallback Mode 3 SG System 5 Operating Manual ...