IMPORTANT
This installation manual shall be used in conjunction with the control panel installation manual available online
from the DSC website at www.dsc.com. All the safety instructions specified within that manual shall be
observed. The control panel is referenced as the “panel” throughout this document. This installation guide
provides the basic wiring, programming and troubleshooting information.
The alarm communicator is a fixed, wall-mounted unit, and shall be installed in the location specified in these
instructions. The alarm communicator module should NOT be installed inside of the metal alarm panel casing;
doing so will significantly impair cellular and RF (Z-Wave) transmissions. The equipment enclosure must be
fully assembled and closed, with all the necessary screws/tabs, and secured to a wall before operation. Internal
wiring must be routed in a manner that prevents:
l
Excessive strain on wire and on terminal connections,
l
Interference between power limited and non power limited wiring,
l
Loosening of terminal connections, or
l
Damage of conductor insulation.
WARNING: Never install this equipment during a lightning storm.
Safety information
The installer must instruct the system user on each of the following:
l
Do not attempt to service this product. Opening or removing covers may expose the user to dangerous
voltages or other risks.
l
Any servicing shall be referred to service persons only.
l
Use authorized accessories only with this equipment.
l
Do not stay close to the equipment during device operation.
l
Do not touch the external antenna.
Alarm.com introduction
The purpose of this guide is to provide installation and operating instructions for the Alarm.com communicator
module. The following sections offer you a brief overview of its capabilities. Some capabilities and features
vary based on the Alarm.com service plan selected. Visit www.alarm.com/Dealer or contact Alarm.com for
more information.
Note:
The Dual Path IP/HSPA 3G module is available in the model TL8803GI-IL2.
Note:
Image sensor functionality may not be enabled in all regions.
The module TL8803GI-IL2 contains the IP/Radio subassembly and the PC-Link to RS422 conversion inter-
face. The module is compatible only with NEO Alarm Control Unit models HS2128, HS2064, HS2032 and
HS2016 software versions 1.1 and above, and PowerSeries Pro models HS3032, HS3128, and HS3248.
IP/HSPA 3G module - TL8803GI-IL2
The Dual Path module enables wireless reporting of all alarms and other system events from the PowerSeries
Neo and PowerSeries Pro control panel using an all-digital, HSPA wireless (cellular) network or an Ethernet
network. The module can be used as the primary communication path for all alarm signaling, or as a backup to
a telephone connection to the central monitoring station. The wireless alarm signaling and routing service is
operated by Alarm.com. The HSPA module also features integrated support for Alarm.com’s home automation
solution with built-in Z-Wave capabilities.
- 5 -
Содержание DSC TL8803GI-IL2
Страница 27: ...TL8803GI IL2...
Страница 29: ...29 49 51 51...
Страница 30: ...30...
Страница 31: ...31...
Страница 35: ...l HSPA 5 2 HSPA l TL8803GI IL2 l TL8803GI IL2 l l l l 16 HSPA TL8803GI IL2 1 1 2 3 RS422 Ethernet 2 35...
Страница 37: ...3 HSPA 4 HSPA A PCLink2 B C Ethernet D 100 30 E PCL 422 PCLink F HSPA HSM2204 2300 37...
Страница 43: ...TL8803GI IL2 Alarm com 18 Alarm com 43...
Страница 48: ...TL8803GI Alarm com 5 2 3 5 13 31 123 _ _ 13 l l l l DSC Alarm com HSPA www alarm com l Alarm com l l HSPA 48...
Страница 50: ...HSPA SN SIM Z Wave 1 Z Wave 1 Z Wave 1 Z Wave 1 Z Wave 1 1 Alarm com Z Wave 50...
Страница 53: ...2019 Tyco 1 800 387 3630 905 760 3000 www dsc com Tyco Tyco 29010718R002...