background image

7

Section 3: Installing the LE4000

Section 3: Installing the LE4000

C24 Communications Enrollment

The LE4000 requires enrolment with C24 Communications to operate. For more information, please visit www.connect24.com, con-

tact C24 Communications customer service at 1-888-251-7458 (US) / 1-888-955-5583 (Canada) or contact the central station to

inquire if they are a C24 Communications Master Reseller.

Note:

Enrollment with C24 Communications should be performed before turning on the LE4000 unit.

Before inserting or removing the SIM card, please ensure the unit is turned off.

Step 1 - Initialize the LE4000 with C24 Communications

The LE4000 can be initialized with C24 Communications by:

web - www.connect24.com

mobile - m.connect24.com

To complete enrollment, a C24 profile, installer ID/PIN (or web credentials) and the 20-digit SIM number are required.

Note:

The SIM activation process with the cellular carrier typically takes between five and ten minutes to complete.

Step 2 - Determine the Best Signal Location

1. Remove the front cover by inserting a screwdriver into each of the slots at the bottom of the enclosure and pushing down.

2. Apply power (DC and/or battery). The LE4000 is now in Placement Test mode.

Step 2a – SIM Card is Activated.

The red LED will be on solid, the blue LED will be off and the signal strength LEDs will display the average signal strength. In this

state, the LE4000 is registered to the cellular network.

Red

Blue

Blue/Green (Top)

Blue/Green (Bottom)

ON

OFF

-

-

If the signal strength is too low (bottom signal LED off or flashing), the LE4000 will move to

Step 3

and scan for carriers with suf-

ficient signal strength and attach to the carrier. If the LE4000 is connected to a carrier with sufficient signal strength (minimum of bot-

tom signal strength LED on solid), it will move to

Step 4

.

Step 2b – SIM Card is Not Activated

The red LED will flash, the blue LED will be off and the signal strength LEDs will display the average signal strength.

Red

Blue

Blue/Green (Top)

Blue/Green (Bottom)

FLASHING

OFF

-

-

In this state, the LE4000 is unable to register to the cellular network because it is inactive. The signal strength indicated is from

any

nearby cell tower (including cellular towers belonging to non-roaming partners) and does

not

necessarily reflect the signal strength of

the intended network. The LE4000 will remain in this state until the SIM is activated. Once the SIM is activated, the LE4000 will

move to

Step 2a

.

Step 3 – Carrier Scanning Due To Insufficient Signal Strength

The LE4000 will scan the surrounding cellular network and connect to the carrier to provide a signal strength of at least 7 CSQ. When

this action is being performed, all four LEDs will activate to show a scanning sequence. The LEDs will cycle from top to bottom and

then bottom to top. This cycle will continue until the LE4000 is connected to a carrier with a signal strength above 7 CSQ (minimum

of bottom signal strength LED on solid). This process can take several minutes.

The carrier scanning sequence repeats until complete.

Содержание DSC LE4000

Страница 1: ...ator Installation Manual V5 0 Warning This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The enti...

Страница 2: ...Mode 13 6 2 Panel Transmission Monitoring PTM 13 6 3 Cellular Communications Sequence 13 6 4 Inputs 14 6 5 Outputs 14 6 5 1 Activating the Outputs 14 6 6 Reporting Codes 15 6 7 Swinger Shutdown 15 6 8...

Страница 3: ...idential Fire and Burglary installations the LE4000 is listed as a sole means of communication or as a back up when used in conjunction with a POTS line dialer For UL Residential Fire installations th...

Страница 4: ...nta Band LTE Dual band UMTS Radio Advanced Carrier Selection Cellular Signal Indicator LTE 3G Internet communication with Sur Gard SG System I IP II III IV 5 Compatible with 4 digit or 10 digit Contac...

Страница 5: ...ntal Specifications Operating temperature 0 C 49 C 32 F 120 F Humidity 93 RH Maximum non condensing Mechanical Specifications Dimensions mm 125mm W x 220mm H x 31mm D Dimensions inches 4 9 x 8 7 x 1 2...

Страница 6: ...TE radio module 5 LET external antenna 6 Antenna mounting hardware 7 Wall tamper switch 8 Cover tamper switch 9 Status LEDs see Status LEDs on page 11 10 PC Link connector 11 Battery connector 12 Term...

Страница 7: ...llular network Red Blue Blue Green Top Blue Green Bottom ON OFF If the signal strength is too low bottom signal LED off or flashing the LE4000 will move to Step 3 and scan for carriers with suf ficien...

Страница 8: ...LED will switch to solid and the LE4000 will move to Step 5 Step 5 Receiver Initialization The red LED and the blue LED are both solid and the signal strength LEDs are off Red Blue Blue Green Top Blue...

Страница 9: ...efore mounting to the wall If flush mounting or using with an extension antenna remove the provided breakaway from the trim plate prior to mounting 1 Using the mounting holes on the LE4000 backplate m...

Страница 10: ...r supply Once the connections are completed connect the battery 11 in Parts diagram to a 7 2V 2 2Ah battery Battery Loosen the screw on the movable retaining clip and rotate counterclockwise until it...

Страница 11: ...e If the LE4000 is programmed to be the primary communicator the blue LED remains off but still flashes during the signal transmission as described above Blue Green Top This LED indicates signal stren...

Страница 12: ...2 Flashing Not used 3 Flashing C24 communication configuration trouble 1 ON Radio SIM trouble radio or SIM unresponsive 2 ON Receiver not available trouble 3 ON Supervision trouble 4 ON Case or wall...

Страница 13: ...to the regular line voltage detection The LE4000 monitors the phone line for four consecutive failed attempts within a 12 minute window A failed attempt is assumed to have occurred when a line seizur...

Страница 14: ...and the COM Refer to the wiring diagram at the back of this manual 6 5 Outputs The LE4000 has four programmable outputs to activate in response to the associated events Refer to the LE4000 Wiring Diag...

Страница 15: ...XXX RY XXX FIXED Test Transmission Receiver Path Radio Activation R552 000 RS 000 FIXED Remote Programming Successful Internal Buffer Full E624 000 JL 000 FIXED FTC Restoral R354 000 YK 000 FIXED Com...

Страница 16: ...terminals Note If the unit has previously received programming from C24 Communications a hardware default is required to initiate the down load of the latest configuration Failure to do so results in...

Страница 17: ...key switching configure the Communicator PGM with a time field of 05 In this configuration both arm and disarm generate the pulse l For Maintained key arming configure the Communicator PGM with a tim...

Страница 18: ...French Activation Spanish Activar Deactivate PGM Language Command Label shall not be case sensitive English Deactivate French Desactivation Spanish Desactivar Status Request Language Command Label sh...

Страница 19: ...ne numbers to receiver group 1 or 2 The number programmed in the Communicator must also be programmed as the panel phone number When the communicator detects the phone number it communicates to the re...

Страница 20: ...ntact ID or SIA over the telephone line Blue Green LED Status What it means CSQ Values Signal Strength Status Both Signal Strength LEDs ON Excellent Sig nal Strength 14 l Unit can be installed in the...

Страница 21: ...eless Network Trouble l Ensure the SIM card has been activated l The antenna cable should be plugged securely into the radio connector l Ensure there is good signal strength at least one green light O...

Страница 22: ...elephone line trouble condition l Ensure T1 and R1 of the LE4000 are wired to the TIP and RING terminals of the con trol panel l If the LE4000 is being used as the primary communicator the blue light...

Страница 23: ...gin A search can be performed for a specific account and its current status l SIM status can also be checked through the GVRU Critical Shutdown on LE4000 backup battery with no DC input applied l If t...

Страница 24: ...l be rated LPS power limited Use only power supplies that have AUX output isolated from EGND Typical battery charge 30 50 mA Recommended Model NiMH Rated 7 2V 2 2Ah Use only Model 6PH H AA2200 S D22 f...

Страница 25: ...TIP RING T1 R1 Z1 PGM1 Z2 PGM2 DC IN 1 2 3 4 5 6 7 9 ZONE TERMINALS See Note 1 8 10 NOTES 1 Program the Zone Point as Supervisory type with keypad only annunciation when in Alarm Do NOT use a point th...

Страница 26: ...Unit or separately listed power supply rated for the application 12V 500mA 2 Phone Line Monitoring TLM must be enabled 3 Phone Line trouble is indicated by blue LED on LE4000 4 Connect PGM2 output fr...

Страница 27: ...ecipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT Termination Without prejudice to any other rig...

Страница 28: ...ed to a line as determined by the total RENs contact the local Telephone Com pany For products approved after July 23 2001 the REN for this product is part of the product identifier that has the forma...

Страница 29: ...pair the product under this warranty after a reasonable num ber of attempts will be limited to a replacement of the product as the exclusive remedy for breach of war ranty Under no circumstances shall...

Отзывы: