Section 7: Troubleshooting Guide

Powering up the LE4000

– when powering up the LE4000, always connect the battery (if used) first before connecting primary DC

power from the control panel or transformer.

Wiring Primary

– R-1/T-1 of LE4000 to RING/TIP of control panel, DC power from control panel or DC transformer to DC input,

backup battery.

Wiring Backup

– Incoming line to RING/TIP on LE4000, R-1/T-1 of LE4000 to RING/TIP of control panel, R-1/T-1 of control

panel to house phones, DC power from control panel or DC transformer to DC input, backup battery.

Testing Communications

– when the LE4000 transmits a signal for the control panel, or for an internal transmission, the BLUE

light will flash one time when the signal is transmitted and two times when it gets a kiss-off.

SIM

– the SIM should be activated at least 24 hours prior to installation. The LE4000 will show signal strength with an inactive SIM,

however it will display the signal strength of any available wireless network. The SIM must be active to ensure the signal strength dis-

played is that of the wireless network provider for which the SIM belongs to.

Panel Programming

– the control panel should be programmed to communicate Contact ID or SIA exactly the same way it would be

programmed to communicate Contact ID or SIA over the telephone line.

Blue/Green
LED Status

What it
means:

CSQ Values Signal Strength Status

Both Signal Strength LEDs

ON

Excellent Sig-

nal Strength

14+

l

Unit can be installed in the current mounting location.

Top LED

FLASHING

with

bottom LED

ON

Excellent Sig-

nal Strength

11-13

l

Unit can be installed in the current mounting location.

Bottom LED

ON

Good Signal

Strength

7-10

l

Unit can be installed in the current mounting location.

Bottom LED

FLASHING

Poor Signal

Strength

5-6

(no trouble)

1-4

(with trouble)

l

Ensure the antenna cable is plugged securely into the radio

connector.

l

If the SIM is active, connect a battery to the unit and test

various locations for good/excellent signal strength.

l

Connect an antenna extension kit (LTE-8ANT, LTE-

15ANT, LTE-25ANT, LTE-50ANT).

Both LEDs

OFF

No Signal

Strength

0

l

If the red LED is also FLASHING, refer to the RED LED

chart.

l

Verify SIM card is activated.

l

Ensure the antenna cable is plugged securely into the radio con-

nector.

l

If the SIM is active, connect a battery to the unit and test vari-

ous locations for good/excellent signal strength.

l

Connect an antenna extension kit (LTE-8ANT, LTE-15ANT,

LTE-25ANT, LTE-50ANT).

Both LEDs

FLASHING

ON/OFF

together

Signal Strength

is invalid

N/A

Radio is in process of network registration.

Both LEDs

ALTERNATING

Radio Reset

Sequence

N/A

Radio is performing a Reset. If the issue persists, please verify the SIM

card is inserted correctly.

LE4000 Installation Manual

Содержание DSC LE4000

Страница 1: ...ator Installation Manual V5 0 Warning This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The enti...

Страница 2: ...Mode 13 6 2 Panel Transmission Monitoring PTM 13 6 3 Cellular Communications Sequence 13 6 4 Inputs 14 6 5 Outputs 14 6 5 1 Activating the Outputs 14 6 6 Reporting Codes 15 6 7 Swinger Shutdown 15 6 8...

Страница 3: ...idential Fire and Burglary installations the LE4000 is listed as a sole means of communication or as a back up when used in conjunction with a POTS line dialer For UL Residential Fire installations th...

Страница 4: ...nta Band LTE Dual band UMTS Radio Advanced Carrier Selection Cellular Signal Indicator LTE 3G Internet communication with Sur Gard SG System I IP II III IV 5 Compatible with 4 digit or 10 digit Contac...

Страница 5: ...ntal Specifications Operating temperature 0 C 49 C 32 F 120 F Humidity 93 RH Maximum non condensing Mechanical Specifications Dimensions mm 125mm W x 220mm H x 31mm D Dimensions inches 4 9 x 8 7 x 1 2...

Страница 6: ...TE radio module 5 LET external antenna 6 Antenna mounting hardware 7 Wall tamper switch 8 Cover tamper switch 9 Status LEDs see Status LEDs on page 11 10 PC Link connector 11 Battery connector 12 Term...

Страница 7: ...llular network Red Blue Blue Green Top Blue Green Bottom ON OFF If the signal strength is too low bottom signal LED off or flashing the LE4000 will move to Step 3 and scan for carriers with suf ficien...

Страница 8: ...LED will switch to solid and the LE4000 will move to Step 5 Step 5 Receiver Initialization The red LED and the blue LED are both solid and the signal strength LEDs are off Red Blue Blue Green Top Blue...

Страница 9: ...efore mounting to the wall If flush mounting or using with an extension antenna remove the provided breakaway from the trim plate prior to mounting 1 Using the mounting holes on the LE4000 backplate m...

Страница 10: ...r supply Once the connections are completed connect the battery 11 in Parts diagram to a 7 2V 2 2Ah battery Battery Loosen the screw on the movable retaining clip and rotate counterclockwise until it...

Страница 11: ...e If the LE4000 is programmed to be the primary communicator the blue LED remains off but still flashes during the signal transmission as described above Blue Green Top This LED indicates signal stren...

Страница 12: ...2 Flashing Not used 3 Flashing C24 communication configuration trouble 1 ON Radio SIM trouble radio or SIM unresponsive 2 ON Receiver not available trouble 3 ON Supervision trouble 4 ON Case or wall...

Страница 13: ...to the regular line voltage detection The LE4000 monitors the phone line for four consecutive failed attempts within a 12 minute window A failed attempt is assumed to have occurred when a line seizur...

Страница 14: ...and the COM Refer to the wiring diagram at the back of this manual 6 5 Outputs The LE4000 has four programmable outputs to activate in response to the associated events Refer to the LE4000 Wiring Diag...

Страница 15: ...XXX RY XXX FIXED Test Transmission Receiver Path Radio Activation R552 000 RS 000 FIXED Remote Programming Successful Internal Buffer Full E624 000 JL 000 FIXED FTC Restoral R354 000 YK 000 FIXED Com...

Страница 16: ...terminals Note If the unit has previously received programming from C24 Communications a hardware default is required to initiate the down load of the latest configuration Failure to do so results in...

Страница 17: ...key switching configure the Communicator PGM with a time field of 05 In this configuration both arm and disarm generate the pulse l For Maintained key arming configure the Communicator PGM with a tim...

Страница 18: ...French Activation Spanish Activar Deactivate PGM Language Command Label shall not be case sensitive English Deactivate French Desactivation Spanish Desactivar Status Request Language Command Label sh...

Страница 19: ...ne numbers to receiver group 1 or 2 The number programmed in the Communicator must also be programmed as the panel phone number When the communicator detects the phone number it communicates to the re...

Страница 20: ...ntact ID or SIA over the telephone line Blue Green LED Status What it means CSQ Values Signal Strength Status Both Signal Strength LEDs ON Excellent Sig nal Strength 14 l Unit can be installed in the...

Страница 21: ...eless Network Trouble l Ensure the SIM card has been activated l The antenna cable should be plugged securely into the radio connector l Ensure there is good signal strength at least one green light O...

Страница 22: ...elephone line trouble condition l Ensure T1 and R1 of the LE4000 are wired to the TIP and RING terminals of the con trol panel l If the LE4000 is being used as the primary communicator the blue light...

Страница 23: ...gin A search can be performed for a specific account and its current status l SIM status can also be checked through the GVRU Critical Shutdown on LE4000 backup battery with no DC input applied l If t...

Страница 24: ...l be rated LPS power limited Use only power supplies that have AUX output isolated from EGND Typical battery charge 30 50 mA Recommended Model NiMH Rated 7 2V 2 2Ah Use only Model 6PH H AA2200 S D22 f...

Страница 25: ...TIP RING T1 R1 Z1 PGM1 Z2 PGM2 DC IN 1 2 3 4 5 6 7 9 ZONE TERMINALS See Note 1 8 10 NOTES 1 Program the Zone Point as Supervisory type with keypad only annunciation when in Alarm Do NOT use a point th...

Страница 26: ...Unit or separately listed power supply rated for the application 12V 500mA 2 Phone Line Monitoring TLM must be enabled 3 Phone Line trouble is indicated by blue LED on LE4000 4 Connect PGM2 output fr...

Страница 27: ...ecipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT Termination Without prejudice to any other rig...

Страница 28: ...ed to a line as determined by the total RENs contact the local Telephone Com pany For products approved after July 23 2001 the REN for this product is part of the product identifier that has the forma...

Страница 29: ...pair the product under this warranty after a reasonable num ber of attempts will be limited to a replacement of the product as the exclusive remedy for breach of war ranty Under no circumstances shall...

Отзывы: