408–6929

MTA Terminating Head 58246–1

Rev C

2 of 5

WI E SI E AW

MTA–100 IDC RECEPTACLE CONNECTORS WITH LOCKING RAMP

WIRE SIZE, AWG

COLOR CODE

WITHOUT POLARIZING TABS

WITH POLARIZING TABS

22

Red

640440
641237
641534

643498
644314

643813
644042
644083

644677

24

Natural

640441
641238

641535
644574

643814
644020

644312

26

Blue

640442
641239
641536

643828
644315

643815
644043
644313

–––

28

Green

640443
641240

641537

643816
644044

–––

Figure 2

Wire retainers are removed to provide a 
connector for testing only. Do NOT use such
connectors for production applications.

3. . Place connector in tool and make a test
termination using the procedures described in
Section 4, TERMINATING PROCEDURE, Steps 1
through 6.

4. Push connector out of right side of head.

5. Inspect termination in accordance with Section
5, INSPECTION, Steps 1 through 6.

If you determine that the wire insertion depth is
incorrect, proceed to Paragraph 3.3, Wire Insertion
Depth Adjustment.

3.2. For Pistol Grip Pneumatic Handle Assembly

1. Perform the procedure outlined in Paragraph
3.1, For Pistol Grip Manual Handle Assembly,
Steps 1 through 4.

2. Inspect termination to ensure that conductor is
terminated past the lead–in transition and is
positioned about halfway into the contact slot. See
Figure 3.

Figure 3

Test Connector

Contact
(Partially
Removed)

Production Connector

Improper
Cut

Deformation

Lead–In

Front Beam

Contact Slot

1.02 [.040] Min.

Wire Retainer
(Removed)

Lock (Ramp)

Lance

Right

Wrong

Wrong

CAUTION