Service Engineer’s Manual 

 
 
 

 

 

Содержание GT90-B7113

Страница 1: ...1 http www tyan com GT90 B7113 Service Engineer s Manual...

Страница 2: ...2 http www tyan com...

Страница 3: ...ing liability or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without no...

Страница 4: ...se limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio freq...

Страница 5: ...not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Disp...

Страница 6: ...ional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter 4 Motherboard Information This chapter list...

Страница 7: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Страница 8: ...bol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as...

Страница 9: ...ock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety require...

Страница 10: ...Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that...

Страница 11: ...of explosion Replace the battery only with a spare designated for your product Do not attempt to recharge the battery Dispose of used batteries according to the instructions of the manufacturer Do not...

Страница 12: ...age requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider Examples of damage requiring service include The power cord extension c...

Страница 13: ...Removing the Chassis Cover 35 2 1 2 Replacing the Chassis Cover 38 2 1 3 Installing the CPU and Heat sink 40 2 1 4 Installing the Memory 43 2 1 5 Installing the Expansion Card 46 2 1 6 Installing 2 5...

Страница 14: ...Chassis 92 4 7 Installing the Memory 94 4 8 Finishing Up 98 Chapter 5 BIOS Setup 99 5 1 About the BIOS 99 5 1 1 Setup Basics 99 5 1 2 Getting Help 100 5 1 3 In Case of Problems 100 5 1 4 Setup Variati...

Страница 15: ...on 178 5 5 5 IIO Configuration 183 5 5 6 Advanced Power Management Configuration 199 5 6 Server Management 205 5 6 1 System Event Log 207 5 6 2 BMC Network Configuration 208 5 7 Security 210 5 7 1 Sec...

Страница 16: ...http www tyan com 16 NOTE...

Страница 17: ...design and lightning fast PCI E bus implementation The GT90 B7113 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage TYAN also offers the G...

Страница 18: ...Type 12 3 5 Hot Swap HDD 4 2 5 Hot Swap NVMe 7mm HDD Backplane Support NVMe SATA 6Gb s Supported HDD Interface 12 SATA 6Gb s 4 NVMe System Cooling Configuration FAN 6 4cm fans Power Supply Type RPSU I...

Страница 19: ...y Module DCPMM only supported with specific 2nd Gen Intel Xeon Scalable Processor codename Cascade Lake Please contact Tyan Technical Support for more detail Expansion Slots Others 1 PCI E Gen3 x16 OC...

Страница 20: ...Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard manag...

Страница 21: ...Gross Weight 32 kg 70 5 lbs Net weight 22 kg 48 5 lbs Front Panel Buttons 1 PWR w LED 1 ID w LED LEDs 1 HDD 1 BMC event External Drive Bay Q ty Type 12 3 5 Hot Swap HDD 4 2 5 Hot Swap SATA SSD NVMe 7m...

Страница 22: ...th 2nd Gen Intel Xeon Scalable Processor codename Cascade Lake and in a 1 DIMM per channel configuration Intel Optane DC Persistent Memory Module DCPMM only supported with specific 2nd Gen Intel Xeon...

Страница 23: ...ture for CPU memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Serv...

Страница 24: ...ing Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Barebone 1 G...

Страница 25: ...0 Platinum w PFC redundant power supply pre installed 6 40 40 56mm Fan pre installed 1 S7113GMRE Motherboard pre installed 1 M7113 3416 16I Storage Mezzanine Card pre installed only for U12E4HR SKU 3...

Страница 26: ...swap external 2 5 7mm SATA NVMe SSD HDD B7113V12E4HR SKU Configuration 12 hot swap internal 3 5 SATA HDD 4 hot swap external 2 5 7mm NVMe SSD No Description 1 Front Panel Warning LED 2 Front Panel HD...

Страница 27: ...OFF Solid On Access Activity OFF Blinking HDD Fail Solid On Don t care Identify Blinking 1Hz Don t care Rebuild Blinking 4Hz Don t care Front Panel LED Indications B7113G90V12E4HR LED Color Behavior H...

Страница 28: ...http www tyan com 28 1 5 3 System Rear View No Description 1 PSU1 2 PSU0 3 ID Button w blue LED 4 OCP Card Area 5 IPMI LAN 6 USB3 0 Ports 7 VGA Port 8 Serial Port...

Страница 29: ...or Hot spot occur OTP Fan fault Input AC UV 12V output occur OVP UVP or OCP without 5Vsb Solid amber Boot loader mode operating 2Hz Blink green 1Gbps LAN Port LAN Indications 1Gbps LAN Link Activity L...

Страница 30: ...http www tyan com 30 1 5 5 System Top View No Description No Description 1 FAN1 6 FAN6 2 FAN2 7 Cable Cover 3 FAN3 8 PSU1 4 FAN4 9 PSU0 5 FAN5 10 Storage Card M7113 3416 16I...

Страница 31: ...http www tyan com 31 No Description No Description 1 FAN1 6 FAN6 2 FAN2 7 Cable Cover 3 FAN3 8 PSU1 4 FAN4 9 PSU0 5 FAN5...

Страница 32: ...http www tyan com 32 NOTE...

Страница 33: ...ccidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static...

Страница 34: ...ssis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the...

Страница 35: ...s how to install components on to the motherboard including CPUs memory modules and Add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove the GT90 B7113 chassis cover 1 Loo...

Страница 36: ...http www tyan com 36 3 Unscrew the front top cover 4 Press the tabs on both sides to lift up the front top cover from the chassis...

Страница 37: ...http www tyan com 37...

Страница 38: ...Replacing the Chassis Cover Follow these instructions to replace the GT90 B7113 chassis cover 1 Put down the front top cover and slide it forwards 2 Secure the front top cover by tightening four flat...

Страница 39: ...http www tyan com 39 3 Put down the rear cover and slide it backwards 4 Secure the rear top cover by tightening the thumbscrew...

Страница 40: ...inks 1 Align and install the processor on the carrier 1 Carefully flip the heatsink Then install the carrier assembly on the bottom of the heatsink and make sure the gold arrow is located in the corre...

Страница 41: ...alcohol solvent Then apply new thermal grease before reinstalling the heatsink 3 Carefully flip the heatsink Align the heatsink with the CPU socket by the guide pins and make sure the gold arrow is lo...

Страница 42: ...http www tyan com 42 NOTE When disassembling the heatsink loosen the screws in reverse order 4 3 2 1 5 Repeat the procedures described earlier to install the second processor and heatsink...

Страница 43: ...odules onto the motherboard 1 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly...

Страница 44: ...1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM...

Страница 45: ...P0_MC1_DIM_CH_E1 P0_MC1_DIM_CH_E0 P0_MC1_DIM_CH_F0 Dual CPU Installed CPU0 and CPU1 Quantity of memory installed 2 4 6 8 10 12 14 16 P0_MC0_DIM_CH_A0 P0_MC0_DIM_CH_B1 P0_MC0_DIM_CH_B0 P0_MC0_DIM_CH_C...

Страница 46: ...supports both RJ45 and SFP Bracket Follow these instructions to replace the Rear I O Bracket RJ45 or SFP and install the Expansion Card 1 Unscrew the Rear IO RJ45 Bracket 2 Remove the RJ45 Bracket an...

Страница 47: ...http www tyan com 47 4 Insert the expansion card onto the OCP riser card slot and use 4 screws to secure it to the chassis...

Страница 48: ...lling 2 5 Hard Drives The GT90 B7113 supports four 2 5 SSDs HDDs Follow these instructions to install a hard drive 1 Press the tab to release the lever 2 Pull the HDD tray away from the chassis 3 Plac...

Страница 49: ...http www tyan com 49 4 Reinsert the HDD tray into the HDD cage Close the lever...

Страница 50: ...The GT90 B7113 supports twelve 3 5 HDDs Follow these instructions to install a hard drive 1 Push the tabs on both sides to pull open the slide out HDD tray 2 Push the tab to release the 3 5 HDD carrie...

Страница 51: ...http www tyan com 51 3 Place a 3 5 HDD into the HDD carrier 4 Reinsert the HDD carrier into the chassis Close the lever...

Страница 52: ...ck mounting kit Rack mounting kit Rails x 2 Mounting Ears x 2 Screw Sacks x 2 2 2 1 Installing the Server in a Rack Follow these instructions to mount the GT90 B7113 into an industry standard 19 rack...

Страница 53: ...m 53 2 2 2 Installing Slide Rails to the Rack 1 Take out the rails from the accessory kit 2 Attach the rails to the rack Please note that the square stud must be fully attached inside the square hole...

Страница 54: ...http www tyan com 54 3 Repeat the same procedures for the other side...

Страница 55: ...Read the Warning Label on the chassis top cover before you install the chassis 2 Install the chassis Must be done with at least 2 people Properly place the chassis directly on the rack and install 3 F...

Страница 56: ...http www tyan com 56 4 Take out the rack stopper pack from the Accessory Kit 5 Fasten the stopper R L to the rear end of chassis by M5 screws...

Страница 57: ...http www tyan com 57 2 2 4 Removing the Server from Rack 1 Release the chassis ear by loosening the screw 2 Release the stopper R L by loosening M5 screws...

Страница 58: ...http www tyan com 58 3 Pull out the chassis half way to the lock position Caution Remove the server from the rack carefully Must be done with at least 2 people 4 Remove the slide rails from the rack...

Страница 59: ...he S7113GMRE Motherboard M1720G90 FPB Front Panel Board M7113 R8 1F Riser Card M1305G90 BP6E 4 HDD M1304G90 BP12 4 HDD Backplane Board M7113 HSBB High Speed Bridge Board M7113 3416 16I Storage Mezz Ca...

Страница 60: ...B7113 3 4 Replacing the Power Supply To replace the power supply follow these instructions 1 Press the tab as shown to pull out the power supply module 2 Free the power from the power cage 3 Replace...

Страница 61: ...these instructions to replace the M1720G90 FPB Front Panel Board 1 Loosen three screws and disconnect the front panel cable 2 After replacing with a new Front Panel Board follow the steps described ea...

Страница 62: ...ont Panel Board Features M1720G90 FPB Front Panel Board Form Factor 38 8x9 7mm Specifications 1 Pin Header Connector FPIO_1 LED Color State Description BMC fail LED Red ON BMC fail HDD Power Access LE...

Страница 63: ...ckplane Board a M1304G90 BP12 4 HDD Follow these instructions to replace the M1304G90 BP12 4 HDD Backplane Board 1 Pull open the slide out HDD tray 1 Push the tab to release the 3 5 HDD carrier Pull o...

Страница 64: ...the M1304G90 BP12 4 HDD Backplane Board Bracket to lift it up 4 After replacing with a new M1304G90 BP12 4 HDD Backplane Board follow the procedures described earlier in reverse order to reinsert the...

Страница 65: ...ard 2 Pull open the slide out HDD tray 3 Unscrew the HDD Backplane Board and disconnect all cables connected to the HDD Backplane Board for replacement B7113G90V12E4HR B7113G90U12E4HR 4 Follow the pro...

Страница 66: ...orm Factor 19 25mmX398mm Integrated I O Golden Finger Mini PCIe Input J1 SATA HDD Output HDD0 HDD3 b M1305G90 BP6E 4 M1305G90 BP6E 4 HDD Backplane Board Form Factor 303 40 1mm Integrated I O Oculink C...

Страница 67: ...en Finger Mini PCIe JTAG1 FPGA JTAG Program Connector NI b M1305G90 BP6E 4 Location Definition SATA Oculink Connector for SATA NVME0 Oculink Connector for NVMe NVME1 Oculink Connector for NVMe NVME2 O...

Страница 68: ...3 7 Replacing Power Distribution Board Follow these instructions to replace the M1624G90 T PDB Power Distribution Board 1 Pull the power supply modules slightly away from the chassis 2 Unscrew to lif...

Страница 69: ...ct all cables connect to the Power Distribution Board 4 Unscrew to replace the M1624G90 T PDB Power Distribution Board 5 Follow the steps described earlier in reverse order to reinstall the power dist...

Страница 70: ...w M1624G90 T PDB Power Distribution Board Form Factor 112 79 5mm Specifications Power supply link connector J2 J3 PDB board for Motherboard main power in PWR1 PDB board for CPU 12V power in PW3 PW2 PD...

Страница 71: ...r Definitions Location Definition J2 J3 Power supply link connector J4 PDB board and Motherboard link Header PWR1 PDB board for Motherboard main power in PW3 PW2 PDB board for CPU 12V power in PW4 PDB...

Страница 72: ...Riser Card Follow these instructions to replace the M7113 R8 1F Riser Card 1 Disconnect all cables connected to the M7113 3416 16I Storage Mezz card Unscrew the Storage Mezz card to lift it up 2 Unscr...

Страница 73: ...http www tyan com 73 3 Unscrew to replace a new riser card 4 Follow the steps described earlier in reverse order to reinstall the riser card bracket...

Страница 74: ...www tyan com 74 3 8 1 Riser card Feature M7113 R8 1F Riser Card Form Factor 76 8 x 30 6 mm Specification 80 pin Mini PCIE x8 Golden Finger GF1 compatible with Motherboard Mini PCIE Slot J11 PCIE x8 Sl...

Страница 75: ...tions to replace the M7113 3416 16I Storage Mezz Card 1 Disconnect all cables connected to the M7113 3416 16I Storage Mezz card Unscrew the Storage Mezz card to lift it up for replacement 2 Follow the...

Страница 76: ...http www tyan com 76 3 9 1 Storage Mezz Card Feature M7113 3416 16I Storage Mezz Card Form Factor 113x102mm Specification LSI3416 chip SlimSAS x 3 OCULink x1...

Страница 77: ...com 77 3 10 Replacing the Fan Follow these instructions to replace the fan module 1 Disconnect the fan cable 2 Lift up the fan module for replacement 3 Place the new fan into the chassis and reconnect...

Страница 78: ...Replacing the Motherboard After removing all of the aforementioned components follow these instructions to remove the motherboard from the chassis 1 Disconnect all cables 2 Unscrew the motherboard to...

Страница 79: ...http www tyan com 79...

Страница 80: ...http www tyan com 80 NOTE...

Страница 81: ...st conditions MITAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the mother...

Страница 82: ...tp www tyan com 82 4 1 Board Image S7113 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pictu...

Страница 83: ...http www tyan com 83 4 2 Block Diagram S7113 Block Diagram...

Страница 84: ...http www tyan com 84 4 3 Motherboard Mechanical Drawing...

Страница 85: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Страница 86: ...Port COM1 Port Connector VGA_COM1 20 SYSFAN 1 7 Connector J141 8 Front Panel Header FPIO_1 21 PSMI POWER 5VSB ATX GD Connector J147 9 Oculink Connector NVME J127 22 SATA DOM Connector J150 10 Oculink...

Страница 87: ...J146 SYSFAN 5 11 J121 Chassis Intrusion Header open Pin 1 2 Signal INTRUSION_N GND FPIO_1 Front Panel Header Signal Pin Pin Signal VCC3 1 2 VCC3 GND 3 4 GND GND 5 6 GND PW_LED 7 8 NC NC 9 10 ID_LED_PW...

Страница 88: ...http www tyan com 88 PSU_ALERT_N 5 6 ATX_VCC12_PG GND 7 8 KEY VCC3 9 10 ATX_PS_ON_N...

Страница 89: ...2 LFRAME_N ADT0 3 4 KEY ADT1 5 6 RST_N ADT2 7 8 GND ADT3 9 10 CLOCK SERIRQ 11 12 GND PRSNT_N 13 14 V3AUX NC 15 16 EN J150 SATA DOM Connector PIN Define Pin Connects to the Serial ATA ready drives via...

Страница 90: ...and Pin_3 for several seconds to Clear CMOS 4 Put jumper cap back to Pin_1 and Pin_2 Default setting 5 Reconnect power connectors to the motherboard and power on system Clear CMOS PWR1 12 pin Main Po...

Страница 91: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Страница 92: ...simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard w...

Страница 93: ...ad of metal Although the plastic studs are usable MITAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 94: ...essors only 16Gb based memory modules are supported by 2nd Gen Intel Xeon Scalable SP processors only Intel Optane DC Persistent Memory Module DCPMM Implementation Requirements DCPMM memory is support...

Страница 95: ...1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM...

Страница 96: ...P0_MC1_DIM_CH_E1 P0_MC1_DIM_CH_E0 P0_MC1_DIM_CH_F0 Dual CPU Installed CPU0 and CPU1 Quantity of memory installed 2 4 6 8 10 12 14 16 P0_MC0_DIM_CH_A0 P0_MC0_DIM_CH_B1 P0_MC0_DIM_CH_B0 P0_MC0_DIM_CH_C...

Страница 97: ...PMM DRAM4 DRAM4 1 1 1 AD DCPMM DRAM1 DRAM1 DRAM1 DRAM1 DCPMM DRAM1 DRAM1 DRAM1 DRAM1 2 2 1 Asymmetric Population within the Socket iMC1 iMC0 Channel F Channel E Channel D Channel C Channel B Channel A...

Страница 98: ...operly especially SATA cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have exper...

Страница 99: ...and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program...

Страница 100: ...or best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 5 1 4 Setup Variations Not all systems have the same...

Страница 101: ...at can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Memory Information5 This displays the total memory size System Date Set the Date Use Tab t...

Страница 102: ...k Settings Intel Virtual RAID on CPU This formset allows the user to manage Intel Virtual RAID on CPU Intel Optane DC persistent Memory Configuration Configure Intel Optane DC persistent memory module...

Страница 103: ...Settings PCI PCI X and PCI Express Settings USB Configuration USB Configuration Parameters CSM Configuration CSM configuration Enable Disable Option ROM execution settings etc NVDIMM ADR Configuratio...

Страница 104: ...When Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV PXE boot option will not be created Disabled Enabled Ipv4 HTTP Support Enable Ipv4 HTTP Boot Support...

Страница 105: ...6 HTTP boot option will not be created Disabled Enabled IPSEC Certificate Support to Enable Disable IPSEC certificate for Ikev Enabled Disabled PXE boot wait time Wait time to press ESC key to abort t...

Страница 106: ...MD for Volume Management Device on Socket 0 for CPU0 Socket 1 for CPU1 Intel VMD for Volume Management Device for PStack0 Slot 1 4 PStack1 Slot 5 8 PStack2 Slot 9 12 Step 2 Suppose the card is install...

Страница 107: ...http www tyan com 107 5 3 2 1 All Intel VMD Controllers Create RAID Volume This page allows you to create a RAID volume Non RAID Physical Disks Read only...

Страница 108: ...cial characters and is 16 characters or less Volume0 RAID Level Select RAID Level RAID0 Stripe Enable RAID spanned over VMD Controllers Enter RAID spanned over VMD Controllers blank X Port 0 VMD0 INTE...

Страница 109: ...MB Enter desired volume size Maximum size 763099 Create Volume Create a volume with the settings specified above NOTE For Create Volume to be configurable the following items Enable RAID spanned over...

Страница 110: ...http www tyan com 110 5 3 2 1 1 1 Create Volume Press y to create n to discard Volume0 RAID0 Stripe 708 0GB Normal Select to see more information about the RAID volume...

Страница 111: ...http www tyan com 111 5 3 2 1 1 1 1 Volume0 RAID0 Stripe 708 0GB Normal Read only...

Страница 112: ...http www tyan com 112 5 3 2 1 1 1 1 1 Delete Delete the RAID Volume Deleting a volume will reset the disks to non RAID Yes No...

Страница 113: ...http www tyan com 113 5 3 2 1 2 Port 0 VMD0 INTEL SSDPE2MD400G4 SN xxxx Port 1 VMD1 INTEL SSDPEDMD400G4 SN xxxx Read only...

Страница 114: ...IMMs Detected DIMMs 2 DIMMs View and configure installed DCPMMs Regions View and configure regions Namespaces Display create modify and delete namespaces Total Capacity Show total DCPMMs resource allo...

Страница 115: ...http www tyan com 115 Preferences View and or modify user preferences...

Страница 116: ...ID 0x0001 DIMM ID 0x1011 View DIMM details Monitor health Display DIMM health status and thresholds Update firmware Go to the update firmware page Configure security Go to the configure security page...

Страница 117: ...Show or hide additional details about the DIMM Disabled Enabled Monitor health Display DIMM health status and thresholds Update firmware Go to the update firmware page Configure security Go to the co...

Страница 118: ...Show or hide additional details about the DIMM Disabled Enabled Monitor health Display DIMM health status and thresholds Update firmware Go to the update firmware page Configure security Go to the co...

Страница 119: ...r health Controller temperature C Controller temperature in Celsius 98 Media temperature C Media temperature in Celsius 82 Percentage remaining Percentage remaining 50 Apply changes Apply changes Back...

Страница 120: ...Update firmware File Please provide file path relative to the root directory of the device containg the new firmware For example firmware newFirmware bin Update Update the firmware verison Back to ma...

Страница 121: ...http www tyan com 121 5 3 3 1 5 Configure security State Disabled Frozen Back to main menu Return to the main menu...

Страница 122: ...http www tyan com 122 5 3 3 2 Regions Create goal config Create goal configuration of DIMM regions Back to main menu Return to the main menu...

Страница 123: ...ystem physical address space 0 Memory Mode Set the percentage of the total capacity to use in Memory Mode 0 100 Due to platform memory alignment requirements this value will be aligned automatically 0...

Страница 124: ...http www tyan com 124 Create goal config Create goal config on selected target Back to Regions menu View and configure regions Back to main menu Return to the main menu...

Страница 125: ...http www tyan com 125 5 3 3 3 Namespaces Create namespace Create namespace with desired configuration Back to main menu Return to the main menu...

Страница 126: ...http www tyan com 126 5 3 3 4 Total Capacity Back to main menu Return to the main menu...

Страница 127: ...nostics test Enabled Disabled DIMM ID 0x0011 DIMM to diagnose Enabled Disabled DIMM ID 0x1011 DIMM to diagnose Enabled Disabled Config diagnostics Perform platform configuration diagnostics test Enabl...

Страница 128: ...http www tyan com 128 Security diagnostics Perform security diagnostics test Enabled Disabled Execute tests Execute selected diagnostic tests Back to main menu Return to the main menu...

Страница 129: ...http www tyan com 129 5 3 3 5 1 Execute tests Read only...

Страница 130: ...playing capacities Use Auto x1024 or Auto_10 x1000 to automatically select the best format Auto Auto_10 B MB MiB GB GiB TB TiB App Direct settings View modify the interleaving settings for creating Ap...

Страница 131: ...m 131 5 3 4 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available...

Страница 132: ...Enable ACPI Auto Configuration Enable or disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enable or disable System ability to Hibernate OS S4 Sleep State This option may not b...

Страница 133: ...board VGA Enable Disable SPEED VGA Disabled Enabled ICC Clock Spread Spectrum Turn on off Spread Spectrum Setting of IsCLK Disabled Enabled Chassis Intrusion detect ENABLED when a chassis open event i...

Страница 134: ...l to full speed automatic or manual Full Speed Automatic Manual NOTE PWM Minimal Duty Cycle menu is available when Auto Fan Control is set to Manual PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 BM...

Страница 135: ...http www tyan com 135 CRPS Support CRPS Support Disabled Enabled Number of PSU Number of PSU 1 1 1...

Страница 136: ...136 5 3 7 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE SDR can not be mo...

Страница 137: ...http www tyan com 137 5 3 8 AST2500 Super IO Configuration Super IO Chip Read only...

Страница 138: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6...

Страница 139: ...d Select Dynamic Time system will wake on the current time increase minute s Disabled Fixed Time Dynamic Time When Wake system from S5 is set to Fixed Time Wake up hour Select 0 23 For example enter 3...

Страница 140: ...direction enable or disable Disabled Enabled COM1 Serial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Settings The settings specify how the host computer which th...

Страница 141: ...ial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with th...

Страница 142: ...F8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode On this mode enabled only text will be sent This is to capture Terminal data Disable...

Страница 143: ...M1 Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When Bootloader is selected then Legacy Console Redirection is disabled before booting t...

Страница 144: ...Server OS through a serial port COM1 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Sett...

Страница 145: ...g data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires...

Страница 146: ...has UEFI X Legacy X Option ROM s VIDx1000 DIDxAC s0 Bx5E Dx0 Fx0 Enabled Disabled Slot OcuLink0 3 Empty Enable or Disable Option ROM execution for selected Slot Enabled Disabled Slot OCP Network Contr...

Страница 147: ...or Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe Devices this opt...

Страница 148: ...no USB devices are connected DISABLE option will keep USB devices available only for EFI applications Enabled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support Th...

Страница 149: ...e time out value for Control Bulk and Interrupt transfers 1 sec 5 sec 10 sec 20 sec Device reset time out USB mass storage device Start Unit command time out 10 sec 20 sec 30 sec 40 sec Device power u...

Страница 150: ...es Set display mode for Option ROM Force BIOS Keep Current Network Controls the execution of UEFI and Legacy PXE OpROM Legacy Do not launch UEFI Storage Controls the execution of UEFI and Legacy Stora...

Страница 151: ...http www tyan com 151 Other PCI Devices Determines OpROM execution policy for devices other than Network Storage or Video Legacy Do not launch UEFI...

Страница 152: ...http www tyan com 152 5 3 15 NVDIMM ADR Configuration Assert ADR on Reset Assert ADR on Reset Disabled Enabled Assert ADR on Shutdown Assert ADR on Shutdown Disabled Enabled...

Страница 153: ...U Registration Sign Up the current CPU This item support INTEL CPU sign the CPU will record current CPU Once BIOS checked different with registered CPU show WARNING message on POST screen Deregistrati...

Страница 154: ...154 5 3 17 Memory Registration Sign Up the current Memory Sign the Memory will record current Memory Once BIOS checked different with registered WARNING message on POST screen Deregistration Sign Up K...

Страница 155: ...http www tyan com 155 5 4 Platform Configuration PCH Configuration Displays and provides option to change the PCH Settings Server ME Configuration Configure Server ME Technology Parameters...

Страница 156: ...troller Hub devices PCI Express Configuration PCI Express Configuration settings PCH SATA Configuration SATA devices and settings PCH sSATA Configuration sSATA devices and settings USB Configuration U...

Страница 157: ...http www tyan com 157 5 4 1 1 PCH Devices Restore AC Power Loss Select S0 S5 for ACPI state after a G3 Power On Power Off Last State...

Страница 158: ...http www tyan com 158 5 4 1 2 PCI Express Configuration PCI Express Root Port 1 Port 20 PCI Express Root Port 1 Port 20 Settings...

Страница 159: ...press Root Port Disabled Enabled PCIE ASPM PCI Express Root port ASPM Setting Disabled ASPM ASPM L1 ASPM Auto L1 Substates PCI Express L1 Substates settings Disabled L1 1 L1 2 L1 1 L1 2 PCIe Speed Con...

Страница 160: ...ed Configure SATA as Determines how SATA controller s operate AHCI RAID SATA Port 0 1 2 3 4 5 6 7 Software Preserve Read Only Port 0 Enable or Disable SATA Port Disabled Enabled Hot Plug Designates th...

Страница 161: ...in Up will be performed and only the drives which have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled SATA Device Type Identify the SATA port is connect...

Страница 162: ...r Disable SATA Controller Enabled Disabled Configure sSATA as Determines how SATA controller s operate AHCI RAID sSATA Port 0 1 2 3 4 5 Software Preserve Read Only Port 0 Enable or Disable SATA Port D...

Страница 163: ...enabled for any of ports Staggered Spin Up will be performed and only the drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled sSATA Device...

Страница 164: ...164 5 4 1 5 USB Configuration XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect...

Страница 165: ...led ADR GPIO Select between GPIO_B or GPIO_C GPIO B GPIO C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Enabled Disabled Enable Disable ADR Timer Held off for DEBUG PUR...

Страница 166: ...http www tyan com 166 ADR timer multiplier Select proper ADR timer multiplier x1 8 24 40 56 64 72 80 88 96 x1 x8 x24 x40 x56 x64 x72 x80 x88 x96...

Страница 167: ...http www tyan com 167 5 4 2 Miscellaneous Configuration Active Video Select active video type Onboard Device Offboard Device...

Страница 168: ...http www tyan com 168 5 4 3 Server ME Configuration Read only...

Страница 169: ...option to change the Common RefCode Settings UPI Configuration Displays and provides option to change the UPI Settings Memory Configuration Displays and provides option to change the Memory Settings...

Страница 170: ...isable Logical Processor threads Disabled Enabled Max CPUID Value Limit This should be enabled in order to boot legacy OSes that cannot support CPUs with extended CPUID functions Disabled Enabled Enab...

Страница 171: ...an com 171 Adjacent Cache Prefetch MLC Spatial Prefetcher MSR 1A4h Bit 1 Enabled Disabled Extended APCI Enable Disable extended APIC support Disabled Enabled AES NI Enable Disable AES NI support Enabl...

Страница 172: ...12M 1G 2G MMIO High Base Select MMIO High Base 56T 40T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up to 32xgranu...

Страница 173: ...http www tyan com 173 Numa Enable or Disable Non uniform Memory Access NUMA Disabled Enabled...

Страница 174: ...http www tyan com 174 5 5 3 UPI Configuration UPI General Configuration Displays and provides option to change the UPI General Settings...

Страница 175: ...ast Link Frequency Select Allows for selecting the UPI Link Frequency 9 6GB s 10 4GB s Auto Use Per Link Setting Link L0p Enable Enable Set the c_l0p_en Disable Reset it Auto Auto decides based on Si...

Страница 176: ...1 cluster or 2 clusters depending on IMC interleave SNC and IMC interleave both AUTO will support 1 cluster XPT KTI Prefetch enable 2 IMC way interleave SNC Enable supports Full SNC 2 clusters and 1 w...

Страница 177: ...http www tyan com 177 5 5 3 1 1 UPI Status Read only...

Страница 178: ...feature Auto Sets it to the MRC default setting current default is Enable Auto POR Disable Memory Frequency Maximum Memory Frequency Selections in Mhz Do not select Reserved Auto 2133 2400 2666 2933...

Страница 179: ...http www tyan com 179 Restore NVDIMMs Enables Disables Automatic restoring of NVDIMMs Disabled Enabled Interleave NVDIMMs Controls if NVDIMMs are interleaved together or not Disabled Enabled...

Страница 180: ...http www tyan com 180 5 5 4 1 Memory Topology Read only...

Страница 181: ...ode 1LM Mirror TAD0 Enable Mirror on entire memory for TAD0 Enabled Disabled Enable Partial Mirror Partial mirror mode will enable the required size of memory to be mirrored If rank sparing is enabled...

Страница 182: ...Memory Rack Sparing read only Enable Disable Memory Rank Sparing Disabled Enabled Correctable Error Threshold Correctable Error Threshold 1 32767 used for sparing tagging and leaky bucket 10 SDDC Plu...

Страница 183: ...D for Volume Management Device Configuration menu PCIe Hot Plug Enable Disable PCIe Hot Plug globally Disabled Enabled Auto Manual PCIe ACPI Hot Plug Enable Disable PCIe ACPI Hot Plug globally or allo...

Страница 184: ...5 5 1 Socket 0 Configuration IOU2 IIO PCIe Br3 Selects PCIe port Bifurcation for selected slot s x4x4 x8 Auto Socket 0 PcieBr3D00F0 Port 3A Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2...

Страница 185: ...sed to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable This o...

Страница 186: ...B 256B Auto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state D...

Страница 187: ...x4x4x8 x8x4x4 x8x8 x16 Auto PCI E Completion Timeout Disable Enable disable the Completion Timeout D x F 00 B8h B 4 where x is 0 3 Yes No PCI E Global Timeout Value Program the Completion Timeout Valu...

Страница 188: ...ocket 1 PcieBr2D02F0 Port 2C Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 5A Socket 1 PcieBr2D03F0 Port 2D Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2...

Страница 189: ...used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable This...

Страница 190: ...B 256B Auto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state D...

Страница 191: ...s used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable Thi...

Страница 192: ...CIe port A 6 0 dB 3 5 dB PCI E Port Max Payload Size Set Maxpayload size to 256B if possible 128B 256B Auto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devic...

Страница 193: ...t to VMM through DMAR ACPI Tables Enabled Disabled NOTE When Intel VT for Directed I O VT d is set to Enabled the following items will be available Interrupt Remapping Enable Disable VT_D Interrupt Re...

Страница 194: ...http www tyan com 194 Posted Interrupt Enable Disable VT_D posted interrupt Enabled Disabled Coherency Support Non Isoch Enable Disable Non Isoch VT_D Engine Coherency support Enabled Disabled...

Страница 195: ...http www tyan com 195 5 5 5 4 Intel VMD Technology...

Страница 196: ...l Volume Management Device Technology in this Stack Disabled Enabled Intel VMD for Volume Management Device for PStack1 Enable Disable Intel Volume Management Device Technology in this Stack Disabled...

Страница 197: ...nology in this Stack Disabled Enabled Intel VMD for Volume Management Device for PStack1 Enable Disable Intel Volume Management Device Technology in this Stack Disabled Enabled VMD Port 2A 2B 2C 2D En...

Страница 198: ...MemBar1 attribute Set up VMD Config BAR attribute like 64 bit or prefetchable 32 bit non prefetchable 64 bit non prefetchable 64 bit prefetchable MemBar2 size Setup VMD Memory BAR2 size in bits Min 2...

Страница 199: ...nagement Configuration CPU P State Control P State Control Configuration Sub Menu include Turbo XE and etc Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting Pa...

Страница 200: ...ce state that the BIOS will set before OS hand off Max Performance Max Efficient Set by Intel Node Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Disabled Enabled Turbo Mode Enable...

Страница 201: ...http www tyan com 201 NOTE When CPU Flex Ratio Override is set to Enabled the following item is available CPU Core Flex Ratio Non Turbo Mode Processor Core Ratio Multiplier 23...

Страница 202: ...ates Disable Hardware choose a P state based on OS Request Legacy P States Native Mode Hardware choose a P state based on OS guidance Out of Band Mode Hardware autonomously choose a P state No OS guid...

Страница 203: ...PU C6 report Enable Disable CPU C6 ACPI C3 report to OS Auto Enable Disable Enhanced Halt State C1E Enables the Enhanced C1E state of the CPU takes effect after reboot Enabled Disabled OS ACPI Cx Repo...

Страница 204: ...http www tyan com 204 5 5 6 4 Package C State Control Package C State Control Package C State Limit C0 C1 state C2 state C6 non Retention state C6 Retention state No Limit Auto...

Страница 205: ...led FRB 2 Timer timeout and FRB 2 Timer Policy are read only FRB 2 Timer timeout Enter value Between 3 to 6 min for FRB 2 Timer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FRB 2 Timer Pol...

Страница 206: ...ad only OS Wtd Timer timeout Configure the length of the OS Boot Watchdog Timer Not available if OS Boot Watchdog timer is disabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Confi...

Страница 207: ...to Disabled the following items are read only Erase SEL Choose options for erasing SEL No Yes on next reset Yes on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing E...

Страница 208: ...parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port...

Страница 209: ...y or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port 2 IPV6 Support Enabl...

Страница 210: ...e Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window will...

Страница 211: ...t Mode Secure Boot mode selector Standard Custom In Custom mode Secure Boot Variables can be configured without authentication Standard Custom Restore Factory Keys Force System to User Mode Install fa...

Страница 212: ...ry Keys Force System to User Mode Install factory default Secure Boot key databases Press Yes to proceed No to cancel Reset to Setup Mode Delete all Secure Boot key database from NVRAM Deleting all va...

Страница 213: ...9 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE C0FF Image SHA256 Key source Factory External Mixed Details Export Update Delete Key Exchange Keys Enroll Factory...

Страница 214: ...zed TimeStamps Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UE...

Страница 215: ...0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enable or disable Endless...

Страница 216: ...system boot order Device Name Disabled Hard Drive BBS Priorities Set the order of the legacy devices in this group Network Device BBS Priorities Set the order of the legacy devices in this group USB D...

Страница 217: ...New Boot Option Add boot option Specify name for new boot option Path for boot option Enter the path to the boot option in the format fsx path filename efi Boot option File Path Read only Create Creat...

Страница 218: ...http www tyan com 218 5 8 2 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to delete UEFI Built in EFI Shell...

Страница 219: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Страница 220: ...w tyan com 220 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Use this option to select boot...

Страница 221: ...6 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Страница 222: ...on up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Sta...

Страница 223: ...tialization North Bridge module specific 0x17 Pre memory North Bridge initialization North Bridge module specific 0x18 Pre Memory North Bridge initialization North Bridge module specific 0x19 Pre memo...

Страница 224: ...Memory South Bridge initialization South Bridge module specific 0x3D Post Memory South Bridge initialization South Bridge module specific 0x3E Post Memory South Bridge initialization South Bridge modu...

Страница 225: ...gered by firmware Auto recovery 0xF1 Recovery condition triggered by user Forced recovery 0xF2 Recovery process started 0xF3 Recovery firmware image is found 0xF4 Recovery firmware image is loaded 0xF...

Страница 226: ...odule specific 0x6C North Bridge DXE initialization North Bridge module specific 0x6D North Bridge DXE initialization North Bridge module specific 0x6E North Bridge DXE initialization North Bridge mod...

Страница 227: ...vices connect 0x99 Super IO initialization 0x9A USB initialization is started 0x9B USB Reset 0x9C USB Detect 0x9D USB Enable 0x9E 0x9F Reserved for future AMI codes 0xA0 IDE initialization is started...

Страница 228: ...outh Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Outp...

Страница 229: ...is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 System is waking up from the S2 sleep st...

Страница 230: ...http www tyan com 230 NOTE...

Страница 231: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Страница 232: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion i...

Страница 233: ...67 PCH_SSATA_0123 Slim SAS on MB PCH_SATA_0123 PCH_SATA_4567 PCH_SSATA_0123 PW4 2x5P PWR on PDB J1 3 Slim SAS 2x5P PWR Cable B7113G90U12E4HR PDB or SAS card to HSBB PDB or SAS card Connect to HSBB SAS...

Страница 234: ...2 NVME_2 Oculink Cable 4 NVME_3 NVME_3 2x4P PWR cable J1 PWR3 6 Oculink 2x4P PWR Cable B7113G90U12E4HR M1305G90 BP6E 4 to S7113 MB or Storage card M1305G90 BP6E 4 Connect to S7113 M B or Storage card...

Страница 235: ...rd A table of BIOS Temp sensor name explanation is also included for readers reference Figure 1 Sensor Location NOTE The red spot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is l...

Страница 236: ...http www tyan com 236 BIOS Temp Sensor Name Explanation...

Страница 237: ...http www tyan com 237...

Страница 238: ...DIMM_CH_D Temperature of P1_MC1_DIMM_CH_D P1_MC1_DIMM_CH_E Temperature of P1_MC1_DIMM_CH_E P1_MC1_DIMM_CH_F Temperature of P1_MC1_DIMM_CH_F SYS_Air_Inlet Sensor located on the Front Panel Board MB_Air...

Страница 239: ...ed of SYS_FAN_9 SYS_FAN_10 Fan speed of SYS_FAN_10 SYS_FAN_11 Fan speed of SYS_FAN_11 SYS_FAN_12 Fan speed of SYS_FAN_12 PSU0_Status Current Status of PSU0 PSU0_Temp Temperature of PSU0 PSU0_Fan Fan s...

Страница 240: ...http www tyan com 240 NOTE...

Страница 241: ...2T60400012 930 mm OCuLink 4X 42P OCuLink 4X 42P Compatible Accessories FRU RC 0960 411T60400069 Storage Mezzanine M7113 3416 16I 16 SAS 12Gb HDD SSD supported FRU RC 0950 411T60400015 Riser Card M7113...

Страница 242: ...http www tyan com 242 Sliding Rail Kit FRU AS 9160 452T60400004 Sliding Rail Kit...

Страница 243: ...expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports...

Страница 244: ...roper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manu...