background image

 
 

 

 

S8226 

 Version 1.0

 

 

 

 

Copyright 

Copyright © 2010 MiTAC International Corporation. All rights reserved. No part of 
this manual may be reproduced or translated without prior written consent from 
MiTAC International Corporation. 

 

Trademark 

All registered and unregistered trademarks and company names contained in this 
manual are property of their respective owners including, but not limited to the 
following. 

 

TYAN

®

 is a trademark of MiTAC International Corporation. 

AMD

®

 is a trademark of AMD

®

 Corporation. 

Intel

®

 is a trademark of Intel

®

 Corporation. 

AMI, AMI BIOS are trademarks of AMI Technologies. 
Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

Winbond

®

 is a trademark of Winbond Electronics Corporation. 

 
Notice 

Information contained in this document is furnished by MiTAC International 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
MiTAC assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN

®

 products including liability or 

warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications at 
any time, without notice. In no event will MiTAC be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document. 

 
 

Содержание S8226

Страница 1: ...ks of Microsoft Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewe...

Страница 2: ...http www tyan com 2...

Страница 3: ...ial 25 2 6 Tips on Installing Motherboard in Chassis 26 2 7 Installing the Memory 28 2 8 Attaching Drive Cables 36 2 9 Installing Add In Cards 37 2 10 Connecting External Devices 38 2 11 Installing th...

Страница 4: ...contain the following 1x S8226 Motherboard 1 x S8226 User s manual 1 x S8226 Quick reference guide 1 x TYAN Driver CD 1 x I O shield 2 x Serial ATA Cable 1 x USB 2 0 Cable 1 x Mini SAS to 7 Pin SATA C...

Страница 5: ...ivers and BIOS upgrades 1 2 Hardware Specifications S8226GM3NR Supported CPU Series AMD 45nm 4 Core 6 Core Opteron 4100 Series Processors Lisbon Features HyperTransportTM 3 technology HT3 links provid...

Страница 6: ...Power on mode after power recovery User configurable H W monitoring Form Factor SSI EEB Physical Dimension Board Dimension 12 x13 305x330mm Operating System OS supported list Please visit our Web site...

Страница 7: ...LED Fan fail LED indicator Over temperature warning indicator Fan PSU fail LED indicator System Monitoring Others Watchdog timer support Onboard Chipset Onboard Aspeed AST2050 AST2050 IPMI Feature IP...

Страница 8: ...an com 8 1 3 Software Specifications For OS operation system support please check with TYAN support for latest information Remember to visit our Web site at http www tyan com for the latest AST2050 Us...

Страница 9: ...uch a safely grounded object to release static charge i e power supply case For the safest conditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do no...

Страница 10: ...http www tyan com 10 2 1 Board Image This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture...

Страница 11: ...http www tyan com 11 2 2 Block Diagram S8226 Block Diagram...

Страница 12: ...of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please refer to the above placement for memor...

Страница 13: ...1 PSMI Connector J32 LAN3 Active LED Header J53 HDD Fault Header J73 IPMB Header JP1 JP2 COM2 Function Select Jumper JP3 Clear CMOS Jumper JP4 Chassis Intrusion Header JP5 Front Panel ID LED Header LE...

Страница 14: ...S SKU Only The amber LED lights up when the SAS controller detects errors in RAID Pin Signal 3V GND State Description OFF OFF Power Off LED4 Power On LED ON Green Power On Pin Signal 3VSB GND State De...

Страница 15: ...art Beat LED Blinking Green The LED blinks per second to indicate that the SAS controller is working normally Pin Signal 3VSB GND State Description OFF OFF The LED shuts off when the BMC controller ca...

Страница 16: ...http www tyan com 16 J4 J56 J55 J5 J30 J34 J12 J54 J28...

Страница 17: ...ND 5 6 ID_LED GND HD_LED 7 8 Fault LED1 HD_LED 9 10 Fault LED2 PWR SW 11 12 LAN1_Active_LED PWR SW GND 13 14 LAN1_Active_LED Reset Switch 15 16 SMB_DATA RST SW GND 17 18 SMB_CLK ID Switch 19 20 INTRUD...

Страница 18: ...http www tyan com 18 J29 J31 LED1 J32 J53 J73 J33...

Страница 19: ...identified Off Off System not identified NOTE IPMI can activate ID LED from remote site Please visit the TYAN Web Site at http www tyan com to download the latest AST2050 Software Configuration Guide...

Страница 20: ...http www tyan com 20 JP5 JP1 JP2 JP4 J10...

Страница 21: ...ff system and disconnect both power connectors from the motherboard 2 Use jumper cap to close Pin_2 and Pin_3 for seconds to Clear CMOS 3 Put jumper cap back to Pin_1 and Pin_2 default setting 4 Recon...

Страница 22: ...of operating an unsupported configuration Processor Installation C32 1207 pin Socket for AMD CPU Follow the steps below to install the processors and heat sinks Please note that the illustrations are...

Страница 23: ...y away from the socket and then push it to a fully open position 4 Lift the socket cover to a fully open position 5 Place the CPU in the CPU socket and make sure that the gold arrow is located in the...

Страница 24: ...ce for as long as you own them The overheated processor is dangerous to the motherboard For the safest method of installation and information on choosing the appropriate heat sink using heat sinks val...

Страница 25: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Страница 26: ...uds are usually metal and are gold in color Usually the chassis manufacturer will pre install the support studs If you are unsure of stud placement simply lay the motherboard inside the chassis and al...

Страница 27: ...ad of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 28: ...at http www tyan com for details of the type of memory recommended for your motherboard The following diagram shows common types of DDR3 memory modules Supports U DIMM R DIMM and Low Voltage LV R DIMM...

Страница 29: ...R or DR QR n a 24GB 800MHz 800MHz DR SR or DR SR or DR 24GB 800MHz 800MHz n a QR n a 16GB 1066MHz 1066MHz DR n a SR or DR 16GB 800MHz 1066MHz SR SR SR 12GB 1333MHz 1333MHz SR n a SR 8GB 1333MHz 1333MH...

Страница 30: ...A0 CPU0_DIMM 5 A1 CPU0_DIMM 6 A2 CPU1_DIMM 7 B0 CPU1_DIMM 8 B1 CPU1_DIMM 9 B2 CPU1_DIMM 10 A0 CPU1_DIMM 11 A1 CPU1_DIMM 12 A2 NOTE 1 indicates a populated DIMM slot 2 Paired memory installation for M...

Страница 31: ...R SR DR CPU0_DIMM 2 B1 QR QR QR QR QR QR QR QR QR CPU0_DIMM 3 B2 SR DR SR DR SR DR SR DR SR DR SR DR CPU0_DIMM 4 A0 SR DR SR DR SR DR CPU0_DIMM 5 A1 QR QR QR QR QR QR QR QR QR QR QR CPU0_DIMM 6 A2 SR...

Страница 32: ...5v DIMM0 A0 B0 DIMM1 A1 B1 DIMM2 A2 B2 Max GB Channel 1066MHz 1066MHz DR n a SR or DR 8GB 1333MHz 1333MHz SR n a SR 4GB 1333MHz 1333MHz SR or DR n a n a 4GB NOTE U DIMM can support up to 4GB sized DIM...

Страница 33: ...CPU1_DIMM 12 A2 NOTE 1 indicates a populated DIMM slot 2 Paired memory installation for Max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same o...

Страница 34: ...http www tyan com 34...

Страница 35: ...s the locking levers in the direction shown in the following illustration 2 Align the memory module with the socket The memory module is keyed to fit only one way in the socket 3 Seat the module firml...

Страница 36: ...are very simple There is no need to set Master Slave jumpers on SATA drives If you are in need of SATA SAS cables or power adapters please contact your place of purchase The following pictures illustr...

Страница 37: ...tly in the PCIE_2 slot Simply find the appropriate slot for your add in card and insert the card firmly Do not force any add in cards into any slots if they do not seat in place It is better to try an...

Страница 38: ...y be required to complete the installation Onboard LAN LED Color Definition The three onboard Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different...

Страница 39: ...2 5V 12V 11 23 5V 3 3V 12 24 GND 8 pin PW2 PW3 Signal Pin Pin Signal GND 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V NOTE Please be aware that ATX 2 x ATX12V and ATXGES power supplies may not be compa...

Страница 40: ...roperly especially IDE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have exper...

Страница 41: ...igurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setu...

Страница 42: ...best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BI...

Страница 43: ...unt x System Memory Size xxxx MB System Time HH MM SS System Date MM DD YYYY Use ENTER TAB or SHIFT TAB to select a field Use or to configure system time Select Screen Select Item Enter Go to Sub Scre...

Страница 44: ...on Onboard Devices Configuration Configure CPU Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit CPU Configuration Configure CPU IDE Configuration Configure t...

Страница 45: ...PI SRAT Table C1E Support Processor x Disabled Enabled Enabled P state 0 Enabled Enabled This should be enabled in order to enable or disable the Enhanced Halt State Select Screen Select Item Enter Go...

Страница 46: ...http www tyan com 46 ACPI SRAT Table Enable or disable the building of ACPI SRAT Table Disabled Enabled C1E Support Enable or disable the C1 Enhanced mode Disabled Enabled...

Страница 47: ...effective only if device is accessed through BIOS Disabled Enabled IDE Detect Time Out Sec Select the time out value for detecting ATA ATAPI device s 0 35 at 5 interval BIOS Setup Utility Main Advance...

Страница 48: ...bled Disabled Disabled LBA Mode Auto Disabled Block Multi Sector Transfer Disabled The Data transfer from and to the device occurs one sector at a time Auto The Data transfer from and to the device oc...

Страница 49: ...OST Watchdog timer counting start at Power on stop at OS Boot OS Start at OS Boot Power on Start at power on Disabled POST OS Power On BIOS Setup Utility Main Advanced PCI PnP Boot Security Chipset Ex...

Страница 50: ...Chipset Exit Advanced ACPI Configuration ACPI Version Features ACPI APIC support AMI OEMB table Headless mode ACPI v3 0 Enabled Enabled Disabled Enable RSDP pointers to 64 bit Fixed System Descriptio...

Страница 51: ...S to add a pointer to an OEMB table in the Root System Description Table RSDT table Enabled Disabled NOTE OEMB table is used to pass POST data to the AMI code during ACPI O S operations Headless Mode...

Страница 52: ...ation Auto FAN Control Disabled Sensor Data Register Monitoring Auto Fan Control Switch Disabled fan full speed Enabled fan speed according max temperature Select Screen Select Item Enter Go to Sub Sc...

Страница 53: ...CPU0 DIMM A2 CPU0 DIMM B2 CPU1 DIMM A0 CPU1 DIMM B0 CPU1 DIMM A1 xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK SDR Monitoring Next Page Press E...

Страница 54: ...s Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit Status of BMC Read only Clear BMC System Event Log Clear all events in BMC System Event Log Set LAN Config...

Страница 55: ...e to traverse the event log Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit Read only It can not be modified in user mode 3 3 6 2 Set LAN Configuration BIOS...

Страница 56: ...rce STATIC DHCP Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit IP Address Source Select IPMI IP Address Source STATIC DHCP NOTE IP Address and Subnet Mask...

Страница 57: ...led 033 Press Enter and OK to save LAN configure Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit Current VLAN ID Status Read only It can not be modified in...

Страница 58: ...EF Support Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit PEF Support Enable or disable PEF support Enabled Disabled PEF Action Global Control Select actio...

Страница 59: ...Remote Access Enables remote access to system through serial port Disabled Enabled NOTE The following BIOS items are available only when Remove Access is set to Enabled Serial Port Number Select Seri...

Страница 60: ...Combo Key Support Enable VT UFT8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Sredir Memory Display Delay Gives the delay in seconds to display memory information No Delay Delay 1...

Страница 61: ...Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit Legacy USB Support Enables support for legacy USB AUTO option disables legacy support if no USB devices are connected Enabled Di...

Страница 62: ...Enable or disable the onboard SAS controller Enabled Disabled Onboard VGA Enable or disable the onboard VGA controller Enabled Disabled BIOS Setup Utility Main Advanced PCI PnP Boot Security Chipset...

Страница 63: ...ster 64 32 96 128 160 192 224 248 Allocate IRQ to PCI VGA Yes assigns IRQ to PCI VGA card if card requests IRQ Yes No Palette Snooping This is the default setting and should not be changed unless the...

Страница 64: ...http www tyan com 64 PCI IDE Bus Master Enabled BIOS uses PCI bus mastering for reading writing to IDE drives Enabled Disabled...

Страница 65: ...ootup Num Lock Wait for F1 if Error Hit DEL Message Display Interrupt 19 Capture Endless Boot Disabled Disabled Force BIOS On Enabled Enabled Enabled Disabled Allows BIOS to skip certain tests while b...

Страница 66: ...s for F1 key to be present if error occurs Enabled Disabled Hit DEL Message Display Displays Press DEL to run Setup in POST Enabled Disabled Interrupt 19 Capture Enabled allows option ROMs to trap int...

Страница 67: ...nu Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit Set your boot device priority These can be customized depending on your preference 3 5 3 Hard Disk Drives...

Страница 68: ...nstall or change the password Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit Supervisor Password User Password Read only Change Supervisor Password Install...

Страница 69: ...ING Setting wrong values in below sections may cause system to malfunction NorthBridge Configuration SouthBridge Configuration RD890 Configuration Configure CPU Bridge features Select Screen Select It...

Страница 70: ...ers CPU Node 0 Memory CLK CAS Latency Tcl RAS CAS Delay Trcd Row Precharge Time Trp Min Active RAS Tras RAS RAS Delay Trrd Row Cycle Trc Read to Precharge Trtp Write Recover Time Twr xxx xxx xxx xxx x...

Страница 71: ...d Exit ESC Exit Bank Interleaving Bank Interleave setting has to do with the actual RAM chip properties most good quality RAM chips have 4 bank interleaving and work best at this setting Inter leaving...

Страница 72: ...all of memory is scrubbed in 8 hours Basic Super Disabled Good Max User DRAM ECC Enable DRAM ECC allows hardware to report and correct memory errors automatically maintaining system integrity Enabled...

Страница 73: ...28us 2 56us 5 12us 10 2us 20 5us 41 0us 82 9us 163 8us 327 7us 655 4us L2 L3 Cache BG Scrub Allow the L2 L3 Data Cache RAM to be corrected while idle Disabled 40ns 80ns 160ns 320ns 640ns 1 28us 2 56us...

Страница 74: ...Config Auto Auto Manual Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit DRAM Timing Config Select the DRAM Frequency programming method If Auto the DRAM sp...

Страница 75: ...nction Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Native IDE Enabled Last State Enabled Disabled Enabled Disabled Enabled Select Screen Select Item Enter Go to Sub Screen F1 Gener...

Страница 76: ...rusion Detection Disabled Disable Chassis Intrusion Detection Enabled When a chassis open event is detected the BIOS will report the event Disabled Enabled SGPIO Function Enable or disable the SP5100...

Страница 77: ...Enabled Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit IOMMU Disable or Enable IOMMU function Disabled Enabled Primary Video Controller PCIE GPP1 GPP2 PCI...

Страница 78: ...Configuration Port 02 Features Port 03 Features Port 04 Features Port 09 Features Port 11 Features Port 12 Features Port 13 Features NB SB Port Features GPP1 Core Setting GPP2 Core Setting GPP3a Core...

Страница 79: ...Disabled Force PCIE link speed to GEN1 Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit Gen2 High Speed Mode Disabled force PCIE link speed to GEN1 Auto Dis...

Страница 80: ...and Exit ESC Exit Link ASPM Active State Power Management Disabled L0s L1 L0s L1 L0s Downstream L0s Downstream L1 L1 Immediate ACK When Enabled L1 will be ACK d immediately Disabled Enabled 3 7 3 1 3...

Страница 81: ...Help F10 Save and Exit ESC Exit Turn Off PLL During L1 L23 Enabled Disabled TXCLK Clock Gating in L1 Enabled Disabled LCLK Clock Gating in L1 Enabled Disabled 3 7 3 1 4 SB Core Setting BIOS Setup Uti...

Страница 82: ...it physical addressing Disabled HT supports 40 bit physical addressing Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit HT Extended Address Enabled HT suppor...

Страница 83: ...ut not saved into CMOS Load Optimal Defaults Use this option to load default performance setup values Use this option when system CMOS values have been corrupted or modified incorrectly Load Failsafe...

Страница 84: ...http www tyan com 84 NOTE...

Страница 85: ...r is a memory error Before contacting your vendor or TYAN Technical Support be sure that you note as much as you can about the beep code length and order that you experience Also be ready with informa...

Страница 86: ...T1ChHandlerBlock 08 Initializes the CPU The BAT test is being done on KBC Program the keyboard controller command byte is being done after Auto detection of KB MS using AMI KB 5 0A Initializes the 804...

Страница 87: ...e and write contents of ESCD in NVRam 84 Log errors encountered during POST 85 Display errors to the user and gets the user response for error 87 Execute BIOS setup if needed requested 8C Late POST in...

Страница 88: ...http www tyan com 88 NOTE...

Страница 89: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Страница 90: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Страница 91: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Страница 92: ...ster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data transf...

Страница 93: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronous...

Страница 94: ...ard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC c...

Страница 95: ...rs and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating syste...

Страница 96: ...d by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and t...