background image

 
 
 

    

 

 

 

 

S8028 

 

Version 1.00   

 

 

Copyright 

Copyright © MiTAC Computer Corporation, 2010. All rights reserved. No part of 
this manual may be reproduced or translated without prior written consent from 
MiTAC Computer Corp. 

 

Trademark 

All registered and unregistered trademarks and company names contained in 
this manual are property of their respective owners including, but not limited to 
the following. 

 

TYAN

®

 is a trademark of MiTAC Computer Corporation 

AMD

®

, Opteron

®

, and combinations thereof are trademarks of AMD Corporation. 

AMI

®

, AMIBIOS

® 

and combinations thereof are trademarks of AMI Technologies. 

Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

Aspeed

®

 is a trademark of Aspeed Technology Inc. 

 
 

Notice 

Information contained in this document is furnished by MiTAC Computer 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
MiTAC assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN

®

 products including liability or 

warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications 
at any time, without notice. In no event will MiTAC be held liable for any direct 
or indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document.

Содержание S8028

Страница 1: ...demarks of Microsoft Corporation Aspeed is a trademark of Aspeed Technology Inc Notice Information contained in this document is furnished by MiTAC Computer Corporation and has been reviewed for accur...

Страница 2: ...http www TYAN com 2...

Страница 3: ...rial 22 2 6 Tips on Installing Motherboard in Chassis 23 2 7 Installing the Memory 25 2 8 Attaching Drive Cables 30 2 9 Installing Add In Cards 31 2 10 Connecting External Devices 32 2 11 Installing t...

Страница 4: ...TYAN com 4 Before you begin Check the box contents The retail motherboard package should contain the following 1x S8028 Motherboard 1 x S8028 User s manual 1 x S8028 Quick reference guide 1 x TYAN Dr...

Страница 5: ...The S8028 not only empowers you in today s demanding IT environment but also offers a smooth path for future application upgradeability All of these rich feature sets provides the S8028 with the powe...

Страница 6: ...nboard COM 1 port rear VGA 1 D Sub 15 pin VGA port RJ 45 Total 3 GbE ports 1 shared with IPMI Power Proprietary 20 pin 12V single input power connector Front Panel 1 2x12 pin SSI front panel header PS...

Страница 7: ...Operating Environment In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Complaint Yes Motherboard 1 S8028 Motherboard Manual 1 Quick Ref Guide in bulk packing carton Package Contains...

Страница 8: ...http www TYAN com 8...

Страница 9: ...touch a safely grounded object to release static charge i e power supply case For the safest conditions TYAN recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do...

Страница 10: ...TYAN com 10 2 1 Board Image This diagram is representative of the latest motherboard S8028 GM3NR revision available at the time of publishing The board you receive may not look exactly like the above...

Страница 11: ...http www TYAN com 11 2 2 Block Diagram S8028GM3NR Block Diagram Represents all SKUs...

Страница 12: ...of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please refer to the above placement for memor...

Страница 13: ...in Header J19 Front Panel Pin Header J21 USB Pin Header J25 Clear CMOS J29 BMC front panel lock Switch J33 IPMB Pin Header J35 LAN3 LED Active Header J41 TPM Configuration Header J46 SPI BIOS programm...

Страница 14: ...M 12V TACH GND GND TACH 12V PWM J8 5 PIN PSMI Connector SMBUSCL SMBUSDA ALERT GND VDD_3P3_DUAL J9 2 PIN INTRUDER Switch INTRUDER_L GND J17 2 PIN Power Button Header Pin1 FP_PWR_SW_N GND J18 3PIN x2 _...

Страница 15: ...HD LED WARN_LED HD LED WARN_LED PWR_SW LAN1_LED GND LAN1_LED RST_SW SDA GND SCL ID_SW INTRUDER_L 21 TEMP 22 LAN2_LED 23 NMI_SW 24 LAN2_LED J21 USB Pin Header 5PIN x2 _ NP9 5VPWR 5VPWR USB2 USB3 USB2 U...

Страница 16: ...onnect both power connectors from the motherboard 2 Put jumper cap back to Pin_1 and Pin_2 default setting 3 Use jumper cap to close Pin_2 and Pin_3 for several seconds to Clear CMOS 4 Reconnect power...

Страница 17: ...ssors are certified and supported with this motherboard Check our website for latest processor support http www TYAN com TYAN is not liable for damage as a result of operating an unsupported configura...

Страница 18: ...TYAN com 18 Step 1 Locate the CPU socket Step 2 Press the load lever with your thumb and then move it to the right until it released from the retention tab Step 3 Move the load lever to a fully open...

Страница 19: ...http www TYAN com 19 Step 4 Lift the load plate to a fully open position Step 5 Remove the PnP cap from the CPU socket The CPU Socket is illustrated in the image right...

Страница 20: ...s in only one correct orientation DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU Step 7 Close the load lever of the socket and press the CPU...

Страница 21: ...performance for as long as you own them The overheated processors is dangerous to the motherboard For the safest method of installation and information on choosing the appropriate heat sink using heat...

Страница 22: ...ot to touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as...

Страница 23: ...uds are usually metal and are gold in color Usually the chassis manufacturer will pre install the support studs If you are unsure of stud placement simply lay the motherboard inside the chassis and al...

Страница 24: ...ad of metal Although the plastic studs are usable TYAN recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 25: ...d The following diagram shows common types of DDR3 memory modules 1 For the DIMM number please refer to the motherboard placement in 2 3 Board Parts Jumpers and Connectors for memory installation 2 Re...

Страница 26: ...1 indicates a populated DIMM slot 2 Paired memory installation for Max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 4 D...

Страница 27: ...00MHz 800MHz SR or DR 800MHz 800MHz SR or DR SR or DR 1066MHz 1066MHz SR or DR 1066MHz 1066MHz SR or DR 1066MHz 1066MHz SR or DR SR or DR N A 1333MHz SR or DR N A 1333MHz SR or DR N A 1333MHz SR or DR...

Страница 28: ...Hz 800MHz 2 SR or DR SR or DR 800MHz 800MHz 2 QR SR or DR 800MHz 800MHz 3 SR or DR SR DR SR or DR N A 800MHz 3 SR or DR QR SR or DR 1066MHz 1066MHz 1 SR or DR 1066MHz 1066MHz 1 QR 1066MHz 1066MHz 2 SR...

Страница 29: ...IMM socket by Press the retaining clip outwardly in the following illustration 2 Align the memory module with the socket The memory module is keyed to fit only one way in the socket 3 Hold the DIMM by...

Страница 30: ...re very simple There is no need to set Master Slave jumpers on SATA drives If you are in need of SATA SAS cables or power adapters please contact your place of purchase The following pictures illustra...

Страница 31: ...add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card TIP It s good practic...

Страница 32: ...allation Onboard LAN LED Color Definition The three onboard Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different LED states 10 100 1000 Mbps LAN L...

Страница 33: ...34 4 Pin 12V PWR Connector Output for HDD backplane 12V GND GND 5V We suggest using a 300W per node supply 3Y POWER TECHNOLOGY power supply Model YM 2301D 300W YM 2451C 450W A 300W is sufficient for m...

Страница 34: ...roperly especially IDE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have exper...

Страница 35: ...bject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The setting...

Страница 36: ...less you are absolutely sure of what you are doing The Chipset defaults have been carefully chosen either by TYAN or your system manufacturer for best performance and reliability Even a seemingly smal...

Страница 37: ...PU information System Memory This displays the amount of system memory present on the system System Time Date setup System Time Adjusts the system clock HH 24 hours format MM Minutes SS Seconds System...

Страница 38: ...d ACPI Configuration Event Log Configuration Configure the Event Log Hardware Health Configuration Configure monitor the Hardware Health IPMI 2 0 Configuration IPMI configuration including server moni...

Страница 39: ...driver developer may enable it for the purpose of testing Disabled Enabled Microcode Update Enable disable the CPU Microcode update Disabled Enabled Secure Virtual Machine Mode Enable disable the CPU...

Страница 40: ...isabled Enabled CPU Prefetching Enable or disable CPU prefetching Disabled Enabled IO Prefetching Enable or disable IO prefetching Disabled Enabled Probe Filter Initialization mode for Probe Filter Au...

Страница 41: ...r Both enables both IDE Controller Disabled Primary Secondary Both Hard Disk Write Protect Disable Enable device write protection This will be effective only if device is accessed through BIOS Disable...

Страница 42: ...al Port1 Base Address Disabled 3F8 IRQ4 3E8 IRQ4 Parallel Port Address Allow BIOS to configure Parallel Port Address Disabled 378 3E8 IRQ4 Parallel Port Mode Allow BIOS to configure Parallel Port Mode...

Страница 43: ...to define whether or not to enable APIC features Enabled Disabled AMI OEMB Table Set this value to allow the ACPI BIOS to add a pointer to an OEMB table in the Root System Description Table RSDT table...

Страница 44: ...ww TYAN com 44 3 3 5 Event Log Configuration View Event Log View all unread events on the Event Log Mark all events as read Mark all unread events as read Clear Event Log Discard all events in the Eve...

Страница 45: ...Select Smart FAN mode Disabled Enabled fan speed up as temperature goes up Disabled Enabled CPU FAN Min Duty Cycle This item allows you to set minimum PWM Duty Cycle 30 Duty Cycle 45 60 CPU FAN Min D...

Страница 46: ...http www TYAN com 46 3 3 6 1 Sensor Data Configuration Sub Menu Read only It can not be modified in user mode...

Страница 47: ...nfiguration Set LAN Configuration Parameters Command Set PEF Configuration Set PEF Configuration Parameters Command BMC Watch Dog Timer Action Allows the BMC to reset or power down the system if the o...

Страница 48: ...http www TYAN com 48 3 3 7 1 View BMC System Event Log Sub Menu Read only It can not be modified in user mode...

Страница 49: ...http www TYAN com 49 3 3 7 2 LAN Configuration Sub Menu Read only It can not be modified in user mode...

Страница 50: ...ntrol Select action for PEF Action Global Control Alert Power Down Reset System Power Cycle OEM Action Diagnostic Int Alert Startup Delay Enable disable Alert Startup Delay Disabled Enabled Startup De...

Страница 51: ...http www TYAN com 51 3 3 8 MPS Configuration MPS Revision Set the multi processor specification 1 1 1 4 3 3 9 PCI Express Configuration...

Страница 52: ...Device to use 8 bit Tag field as a requester Auto Disabled No Snoop Enables Disables PCI Express Device No Snoop option Auto Disabled Maximum Read Request Size Set Maximum Read Request Size of PCI Ex...

Страница 53: ...Port for cosole redirection Make sure the selected port is enabled COM1 BMC VUR Serial Port Mode Select Serial Port settings Flow Control Select Flow Control for console redirection None Hardware Soft...

Страница 54: ...type ANSI VT100 VT UTF8 VT UTF8 Combo Key Support Enable VT UFT8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Sredir Memory Display Delay Gives the delay in seconds to display me...

Страница 55: ...Controller Mode Configure the USB 2 0 controller in Hi Speed 480 Mbps or Full Speed 12Mbps Hi Speed Full Speed BIOS EHCI Hand OFF This is a work around for OSes without EHCI hand off support The EHCI...

Страница 56: ...2GHz 1 4GHz 1 6 GHz 1 8GHz 2 0GHz 2 2GHz 2 4GHz 2 6GHz 2 8GHz 3 0GHz 3 2GHz Coherent HT Link Width Configure Coherent HT Width 8bit 16bit NonCoherent HT Link Speed Configure NonCoherent HT frequency A...

Страница 57: ...nd Play operating system No Yes PCI Latency Timer This setting controls how many PCI clocks each PCI device can hold the bus before another PCI device takes over When set to higher values every PCI de...

Страница 58: ...is installed in the system so the card will function correctly Disabled Enabled PCI IDE Bus Master Enabled BIOS uses PCI bus mastering for reading writing to IDE drives Enabled Disabled Offboard PCI I...

Страница 59: ...nabled Disabled Quiet Boot Disabled displays normal POST messages Enabled displays OEM log instead of POST messages Disabled Enabled Add On ROM Display Mode Allows user to force BIOS Option ROM of add...

Страница 60: ...Displays Press DEL to run Setup in POST Enabled Disabled Interrupt 19 Capture Enabled allows option ROMs to trap interrupt 19 Enabled Disabled 3 5 2 Boot Device Priority Boot Device Priority Specifies...

Страница 61: ...visor Password Install or change the password Change User Password Install or change the password Boot Sector Virus Protection When it is set to Enabled BIOS will issue a virus warning message and bee...

Страница 62: ...http www TYAN com 62 3 6 1 Trusted Computing TCG TPM Support Enable Disable TPM TCG TPM 1 1 1 2 support in BIOS No Yes...

Страница 63: ...Allow you to change NorthBridge SouthBridge SR5650 and Onboard Peripherals Configuration 3 7 1 NorthBridge Chipset Configuration Sub Menu Memory Timing Parameters To select which node s timing parame...

Страница 64: ...tting Inter leaving controls how actual hits to memory takes place Enable Bank Memory Interleaving Auto Disabled Node Interleaving Enable Node Memory Interleaving Disabled Enabled Channel Interleaving...

Страница 65: ...CC protection Note The Super ECC mode dynamically sets the DRAM scrub rate so all of memory is scrubbed in 8 hours Basic Super Disabled Good Max User DRAM ECC Enable DRAM ECC allows hardware to report...

Страница 66: ...ming method If Auto the DRAM speed will be based on SPDs If Limit the DRAM speed will not exceed the specified value If Manual the DRAM speed specified will be programmed by users Auto Manual Limit Me...

Страница 67: ...ration Sub Menu OnChip SATA Channel Enable or disable OnChip SATA channel Enabled Disabled OnChip SATA Type Select OnChip SATA type Native IDE RAID AHCI SATA IDE Combined Mode Disabled Enabled PATA Ch...

Страница 68: ...http www TYAN com 68 3 7 3 SR5650 Configuration IOMMU Disable or Enable IOMMU function Disabled Enabled...

Страница 69: ...http www TYAN com 69 3 7 4 Onboard Peripherals Configuration...

Страница 70: ...ew selections you have made are not stored into CMOS System will use the old settings to boot up Discard Changes Use this option to restore all new setup values that you have made but not saved into C...

Страница 71: ...r is a memory error Before contacting your vendor or TYAN Technical Support be sure that you note as much as you can about the beep code length and order that you experience Also be ready with informa...

Страница 72: ...T1ChHandlerBlock 08 Initializes the CPU The BAT test is being done on KBC Program the keyboard controller command byte is being done after Auto detection of KB MS using AMI KB 5 0A Initializes the 804...

Страница 73: ...e and write contents of ESCD in NVRam 84 Log errors encountered during POST 85 Display errors to the user and gets the user response for error 87 Execute BIOS setup if needed requested 8C Late POST in...

Страница 74: ...http www TYAN com 74 NOTE...

Страница 75: ...he power supply and cooling fan The keyboard mouse USB serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other...

Страница 76: ...ort which is called as such because it transmits the eight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after a...

Страница 77: ...re that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form f...

Страница 78: ...CI Peripheral Component Interconnect a 32 or 64 bit local bus data pathway which is faster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which...

Страница 79: ...ory is available to any program running on the computer ROM Read Only Memory a storage chip which contains the BIOS the basic instructions required to boot the computer and start up the operating syst...

Страница 80: ...data transfer rates of the new UltraDMA UltraATA hard drives USB Universal Serial Bus a versatile port This one port type can function as a serial parallel mouse keyboard or joystick port It is fast...

Страница 81: ...ore With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system components to keep their systems running as powerful and productive as...

Страница 82: ...e designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy...