background image

 

http://www.tyan.com

 

 

 

 

S7106 

 Version 1.0

 

 
Copyright 

Copyright © 2017 MiTAC International Corporation. All rights reserved. No part of 
this manual may be reproduced or translated without prior written consent from 
MiTAC International Corporation. 

 

Trademark 

All registered and unregistered trademarks and company names contained in this 
manual are property of their respective owners including, but not limited to the 
following. 

 

TYAN

®

 is a trademark of MiTAC International Corporation. 

Intel

®

 is a trademark of Intel

®

 Corporation. 

AMI, AMI BIOS are trademarks of AMI Technologies. 
Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

Winbond

®

 is a trademark of Winbond Electronics Corporation. 

 
Notice 

Information contained in this document is furnished by MiTAC International 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
MiTAC assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN

®

 products including liability or 

warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications at 
any time, without notice. In no event will MiTAC be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document. 
 
 

Содержание S7106

Страница 1: ...rosoft Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for acc...

Страница 2: ...Installing Motherboard in Chassis 28 2 8 Installing the Memory 30 2 9 Attaching Drive Cables 35 2 10 Installing Add In Cards 36 2 11 Connecting External Devices 37 2 12 Installing the Power Supply 38...

Страница 3: ...ar IO shielding x 3 CPU clip for Narrow Non Fabric CPU Carrier x 2 1 x S7106 Quick Installation Guide 1 x TYAN Driver CD M 2 Screw kit x1 IMPORTANT NOTE Sales samples may not come with any of the acce...

Страница 4: ...deability All of these rich feature sets provide the S7106 with the power and flexibility to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http www tyan...

Страница 5: ...nnector 1 M 2 connector 2242 2260 2280 by PCI E interface sSATA Connector 1 Mini SAS HD 4 ports 2 SATA III Controller Intel C621 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe only for 4 SATA devices Gr...

Страница 6: ...ement AST2500 iKVM Feature IPMI 2 0 compliant baseboard management controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature 24 bit high quality video...

Страница 7: ...to 205W Chipset PCH Intel C622 Memory Supported DIMM Qty 8 8 DIMM slots DIMM Type Speed DDR4 RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS 2666 Capacity Up to 512GB RDIMM 1 024GB LRDIMM 2 048GB LRDIMM 3DS Follow...

Страница 8: ...at rear 2 USB 2 0 ports via cable 1 Type A USB3 0 port COM 2 Ports 1 at rear 1 via cable VGA 2 D Sub ports 1 at rear 1 via cable RJ 45 2 GbE ports 1 Dedicated for IPMI Front Panel 1 2x12 pin SSI fron...

Страница 9: ...onsole Redirection ACPI sleeping states S4 S5 ACPI 6 1 Physical Dimension Form Factor EATX Board Dimension 12 x13 305x330mm Regulation FCC DoC Class B CE DoC Yes Operating Environment Operating Temp 1...

Страница 10: ...st conditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the mother...

Страница 11: ...http www tyan com 11 2 1 Board Image S7106GM2NR...

Страница 12: ...http www tyan com 12 S7106GM2NR L2 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture...

Страница 13: ...http www tyan com 13 2 2 Block Diagram S7106 Block Diagram...

Страница 14: ...http www tyan com 14 2 3 Motherboard Mechanical Drawing...

Страница 15: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Страница 16: ...J26 34 ATX Power Connector 24 pin PWR1 16 sSATA SGPIO Header for SSATA4 SSATA5 SSATA_SGPIO1 35 PSMI Pin Header PSMI_HD1 17 COM2 Header HD_COM2 36 36 pin Vertical Mini SAS HD Connector SATA 3 0 signal...

Страница 17: ...A0 S CPU1 Memory Slot P1_MC0_DIM_CH_A0 L CPU0 Memory Slot P0_MC1_DIM_CH_D0 T CPU1 Memory Slot P1_MC1_DIM_CH_D0 M CPU0 Memory Slot P0_MC1_DIM_CH_E1 U CPU1 Memory Slot P1_MC1_DIM_CH_E1 N CPU0 Memory Slo...

Страница 18: ...A cable TYPEA_USB3 Vertical Type_A USB3 0 Connector Signal Pin Pin Signal 5V 1 2 USB2 0_DATA_N USB2 0_DATA_P 3 4 GND USB3 0_RX_N 5 6 USB3 0_RX_P GND 7 8 USB3 0_TX_N USB3 0_TX_P 9 ID LED_BTN1 Rear IO I...

Страница 19: ...Signal 5V 1 2 P0_RX_N P0_RX_P 3 4 GND P0_TX_N 5 6 P0_TX_P GND 7 8 P0_N P0_P 9 10 OC_N P1_P 11 12 P1_N GND 13 14 P1_TX_P P1_TX_N 15 16 GND P1_RX_P 17 18 P1_RX_N 5V 19 20 Key J26 Internal USB2 0 Header...

Страница 20: ...SMB_DATA TACH12 17 18 SMB_CLK NC 19 20 PWM3 J51 PCH_SATA_RAID_KEY HW Key for Intel VROC NVMe only Pin 1 2 Signal LAN1_LED1_FP LAN1_LINK_ACT FPIO1 Front Panel Connector Signal Pin Pin Signal FP_PW_LED...

Страница 21: ...or Pin 1 2 3 4 Signal GND VCC12 FAN_TACH PWM Use this header to connect the cooling fan to your motherboard to keep the system stable and reliable Note A 4 pin fan is required for fan support 4pin Con...

Страница 22: ...d Disable PC Beep Pin 1 4 Closed Use the External Speaker J118 BMC COM Port debug Jumper Signal Pin Pin Signal BMC_COM2_RXD 1 2 RXD_2 BMC_COM5_RXD 3 1 2 BMC COM Port2 Default 2 3 BMC COMSOLE Port5 J11...

Страница 23: ...GND PIN A9 PIN B1 GND SGPIO _LOAD PIN B2 PIN B3 GND SATA6G_RX_P0 PIN B4 PIN B5 SATA6G_RX_N0 GND PIN B6 PIN B7 SATA6G_RX_P2 SATA6G_RX_N2 PIN B8 PIN B9 GND SGPIO_SATA_DATA OUT0 PIN C1 PIN C2 GND GND PIN...

Страница 24: ...Description OFF OFF The LED shuts off when the power of CPU1 is abnormal ON Green The LED lights up when the power of CPU1 is normally P1_PG_LED1 CPU1 PWOK LED Pin Signal VCC3 GND State Description OF...

Страница 25: ...lation Dual Socket P LGA3647 for Intel Skylake CPU Follow the steps below to install the processors and heat sinks Please note that the illustrations are based on LGA3647 socket which may not look exa...

Страница 26: ...n the heatsink with the CPU socket by the guide pins and make sure the gold arrow is located in the correct direction Then place the heatsink onto the top of the CPU socket 5 Align the heatsink by the...

Страница 27: ...tp www tyan com 27 6 To secure the heatsink use a Security T30 Security Torx to tighten the screws in a sequential order 1 2 3 4 When dissembling the heatsink loosen the screws in reverse order 4 3 2...

Страница 28: ...simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard w...

Страница 29: ...ad of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 30: ...p www tyan com for details of the type of memory recommended for your motherboard Support 16 DDR4 288 pin DIMM slots Support 6 memory channels per CPU RDIMM DDR4 2666Mhz w ECC 1 2V when 1DPC RDIMM DDR...

Страница 31: ..._F0 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks...

Страница 32: ...CH_C0 P1_MC1_DIM_CH_D0 P1_MC1_DIM_CH_E1 P1_MC1_DIM_CH_E0 P1_MC1_DIM_CH_F0 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in e...

Страница 33: ...om 33 Intel Xeon Skylake Scalable Processors Families Support NOTE 1 1DPC One dimm per channel NOTE 2 2DPC Two dimm per channel Physical Ranks are used to calculate DIMM Capacity Supported DRAM Densit...

Страница 34: ...ock a DIMM socket by Press the retaining clip outwardly in the following illustration 2 Align the memory module with the socket such that the DIMM NOTCH match the KEY SLOT on the socket 3 Seat the mod...

Страница 35: ...owing illustrates how to make a SATA Cable connection If you are in need of SATA SAS cables or power adapters please contact your local sales representative 1 SATA drive cable connection 2 SATA drive...

Страница 36: ...for LAN card Standalone G OCP 1 0 PCI E Gen3x8 MEZZ slot f CPU1 for LAN card Simply find the appropriate slot for your add in card and insert the card firmly Do not force any add in cards into any sl...

Страница 37: ...Three 3 onboard Ethernet ports have green and Amber LEDs to indicate LAN status The chart below illustrates the different LED states 1Gbps LAN Link Activity LED Scheme Description Left LED Link Activ...

Страница 38: ...n CPU1Power Connector Signal Pin Pin Signal GND 1 5 P1_P12V GND 2 6 P1_P12V GND 3 7 P1_MEM_P12V GND 4 8 P1_MEM_P12V 2 13 Finishing Up Congratulations on making it this far You have finished setting up...

Страница 39: ...to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are...

Страница 40: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Страница 41: ...for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Platform Information It displays Platform information Memory Information Thi...

Страница 42: ...http www tyan com 42 System Time Adjust the system clock HH 24 hours format MM Minutes SS Seconds...

Страница 43: ...Configure the iSCSI parameters Intel Virtual RAID on CPU This formset allows the user to manage Intel Virtual RAID on CPU Trusted Computing Trusted Computing settings ACPI Settings System ACPI Paramet...

Страница 44: ...ke Settings Serial Port Console Redirection Serial Port Console Redirection Option ROM Dispatch Policy Option ROM Dispatch Policy PCI Subsystem Settings PCI PCI X and PCI Express Settings Network Stac...

Страница 45: ...http www tyan com 45 3 3 1 iSCSI Configuration iSCSI Name The worldwide unique name of iSCSI Initiator Only IQN format is accepted Range is from 4 to 223...

Страница 46: ...http www tyan com 46 3 3 2 Intel R Virtual RAID on CPU...

Страница 47: ...ed Computing Security Device Support Enable or disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will no...

Страница 48: ...nable ACPI Auto Configuration Enable or disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enables or disables System ability to Hibernate OS S4 Sleep State This option may not b...

Страница 49: ...Spread Spectrum Turn on off Spread Spectrum Setting for IsCLK Enabled Disabled Onboard Lan I210 Enable Disable Onboard Lan I210 Disabled Enabled Chassis Intrusion detect Enabled When a chassis open ev...

Страница 50: ...elp Disabled Enabled NOTE Auto Fan Control must be set to Enabled PWM Minimal Duty Cycle menu will appear PWM Minimal Duty Cycle Duty Cycle control range 15 Duty Cycle 30 Duty Cycle 45 Duty Cycle BMC...

Страница 51: ...51 3 3 5 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Страница 52: ...http www tyan com 52...

Страница 53: ...http www tyan com 53...

Страница 54: ...http www tyan com 54 3 3 7 PCIe Slot Configuration Internal OCP Slot Select OCP Slot Bifurcation X16 x8x8 x4x4x4x4 OCP I O Slot Select OCP Bifurcation Load Optrom for PCIE Slot X16 x8x8 x4x4x4x4...

Страница 55: ...http www tyan com 55 3 3 8 AST2500 Super IO Configuration Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA Serial Port 2 Configuration Set Parameters of Serial Port 2 COMA...

Страница 56: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5...

Страница 57: ...tings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select dynamic time system will wake on the current time increase...

Страница 58: ...ort for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the host...

Страница 59: ...al port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with the...

Страница 60: ...e Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to cap...

Страница 61: ...http www tyan com 61 3 3 10 2 Legacy Console Redirection Settings Legacy Serial Redirected Port Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM1...

Страница 62: ...rver OS through a serial port COM1 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setting...

Страница 63: ...n sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses tw...

Страница 64: ...tem OnBoard sSATA Controller Onboard Device has UEFI X Legacy X Embedded ROM s VIDx8086 DIOxA1D2 s0 Bx0 Dx11 Fx5 Disabled Enabled OnBoard SATA Controller Onboard Device has UEFI X Legacy X Embedded RO...

Страница 65: ...M for OnBoard LAN1 I210 PXE ISCSI OnBoard Lan2 I210 Onboard Device has UEFI X Legacy X Embedded ROM s VIDx8086 DIOx1533 s0 Bx2 Dx0 Fx0 Disabled Enabled Riser L Up Empty Enable or Disable Option ROM ex...

Страница 66: ...isables 64bit capable Devices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this option...

Страница 67: ...http www tyan com 67 3 3 13 Network Stack Configuration Network Stack Enable Disable UEFI Network Stack Disabled Enabled...

Страница 68: ...rent Network Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Video Controls the exec...

Страница 69: ...bled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support...

Страница 70: ...vice reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Hos...

Страница 71: ...Platform Configuration Menu PCH Configuration Displays and provides option to change the PCH Settings Miscellaneous Configuration Miscellaneous Configuration Server ME Configuration Configure Server...

Страница 72: ...Controller Hub devices PCI Express Configuration PCI Express Configuration settings PCH SATA Configuration SATA devices and settings PCH sSATA Configuration sSATA devices and settings USB Configurati...

Страница 73: ...http www tyan com 73 3 4 1 1 PCH Devices Configuration PCH state after G3 Select S0 S5 for ACPI state after a G3 S0 S5 Leave power state unchanged...

Страница 74: ...http www tyan com 74 3 4 1 2 PCI Express Configuration PCI Express Root Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 PCI Express Root Port Settings...

Страница 75: ...4 15 16 17 18 19 20 Control the PCI Express Root Port Disabled Enabled PCIE ASPM PCI Express Root port ASPM Setting Disable ASPM ASPM L1 ASPM Auto L1 Substates PCI Express L1 Substates settings Disabl...

Страница 76: ...http www tyan com 76 3 4 1 3 PCH SATA Configuration Submenu...

Страница 77: ...TA as Indentify the SATA port is connected to Solid State Drive or Hard Disk Drive AHCI RAID SATA Port 0 1 2 3 4 5 6 7 Port 0 1 2 3 4 5 6 7 Disabled Enabled Hot Plug Enable Disable SATA Ports Hot Plug...

Страница 78: ...ww tyan com 78 Spin Up Device AHCI Supports Staggered Spin up Disabled Enabled SATA Device Type Indentify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Drive Solid State...

Страница 79: ...http www tyan com 79 3 4 1 4 PCH sSATA Configuration Submenu...

Страница 80: ...lug Designates this port as Hot Pluggable Disabled Enabled Configure as eSATA Configures port as External SATA eSATA Disabled Enabled Spin Up Device If enabled for any of ports Staggerred Spin Up will...

Страница 81: ...3 4 1 5 USB Configuration Submenu XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take ef...

Страница 82: ...Disabled ADR GPIO Select between GPIO_B or GPIO_C GPIO B GPIO C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Enabled Disabled Enable Disable ADR Timer Held off for DEB...

Страница 83: ...er multiplier Select proper ADR timer multiplier x1 8 24 40 56 64 72 80 88 96 x1 x8 x24 x40 x56 x64 x72 x80 x88 x96 3 4 2 Miscellaneous Configuration Submenu Active Video Select active Video type Auto...

Страница 84: ...http www tyan com 84 3 4 3 Server ME Configuration Submenu Read Only...

Страница 85: ...s option to change the Common RefCode Settings UPI Configurtion Displays and provides option to change the UPI Settings Memory Configuration Displays and provides option to change the Memory Settings...

Страница 86: ...gical Processor threads Disabled Enabled Max CPUID Value Limit This should be enabled in order to boot legacy OSes that cannot support CPUs with extended CPUID functions Disabled Enable Execute Disabl...

Страница 87: ...Streamer Prefetcher MSR 1A4h Bit 0 Disabled Enabled Adjacent Cache Prefetch MLC Spatial Prefetcher MSR 1A4h Bit 1 Disabled Enabled Extended APIC Enable disable extended APIC support Disabled Enabled...

Страница 88: ...40T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up to 32x granularity Per stack mmioh resource assignments are mu...

Страница 89: ...http www tyan com 89 3 5 3 UPI Configuration Submenu UPI General Configuration Displays and provides option to change the UPI General Settings...

Страница 90: ...speed Slow Slow Fast Link Frequency Select Allows for selecting the UPI Link frequency 9 6GB s 10 4GB s Auto Use Per Link Setting Link L0p Enable Enable Set the c_L0p_en Disable Reset it Auto Auto de...

Страница 91: ...http www tyan com 91 3 5 3 2 UPI Status Configuration Submenu...

Страница 92: ...Enable Auto POR Disable Memory Frequency Maximum Memory Frequency Selections in Mnz Do not select Reserved Auto 2133 2400 2666 ECC Support Enable Enables DDR ECC Support Disable Disables this feature...

Страница 93: ...http www tyan com 93 3 5 4 1 Memory Topology Configuration Submenu...

Страница 94: ...will disable XPT Prefetch Disabled Enabled Mirror TAD0 Enable Mirror on entire memory for TAD0 Disabled Enabled Enable Partial Mirror Partial mirror mode will enable the required size of memory to be...

Страница 95: ...m Physical Address or Reverse Address Disabled Enabled Patrol Scrub Enable Disable Patrol Scrub Disabled Enabled 3 5 5 IIO Configuration Socket0 Configuration Socket 0 Configuration Socket1 Configurat...

Страница 96: ...t Plug Enable Disable PCIe Hot Plug globally Disabled Enabled PCIe ACPI Hot Plug Enable Disable PCIe ACPI Hot Plug globally or allow per port control When Disabled MSI is generated on HP event When En...

Страница 97: ...1 Socket0 Submenu IOU0 IIO PCIe Br1 Select PCIe port Bifuncation for selected slot s X4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU2 IIO PCIe Br3 Selects PCIe port Bifuncation for selected slot s X4x4x4x4 X...

Страница 98: ...Bifuncation for selected slot s X4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU1 IIO PCIe Br2 Selects PCIe port Bifurcation for selected slot s X4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU2 IIO PCIe Br3 Selects...

Страница 99: ...Intel VT for Directed I O VT d Submenu Intel VT for Directed I O VT d Enable Disable Intel Virtualization Technology for Directed I O VT d by reporting the I O device assignment to VMM through DMAR A...

Страница 100: ...http www tyan com 100 3 5 5 3 Intel VMD technology Submenu...

Страница 101: ...3 5 5 3 1 Intel VMD for Volume Management Device on Socket 0 1 Submenu VMD Config for PStack 0 1 2 Intel VMD for Volume Management D Enable Disable Intel Volume Management Device Technology in this S...

Страница 102: ...agement Configuration CPU P State Control P State Control Configuration Sub Menu include Turbo XE and etc Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting Pac...

Страница 103: ...rmance state that the BIOS will set before OS hand off Max Performance Max Efficient Set by Intel Node Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Disabled Enabled Turbo Mode En...

Страница 104: ...ates Disable Hardware choose a P state based on OS Request Legacy P States Native Mode Hardware choose a P state based on OS guidance Out of Band Mode Hardware autonomously choose a P state No OS guid...

Страница 105: ...nu CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Auto Enable Disable Enhanced Halt State C1E Enables the Enhanced C1E state of the CPU takes effect after reboot Enabled Disabled OS ACPI Cx...

Страница 106: ...http www tyan com 106 3 5 6 4 Package C State Control Submenu Package C State Control Package C State Limit C0 C1 state C2 state C6 non Retention state C6 Retention state No Limit Auto...

Страница 107: ...mer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FBR 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing R...

Страница 108: ...sabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled...

Страница 109: ...boot Enabled Disabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Log EFI...

Страница 110: ...http www tyan com 110 3 6 2 BMC Network Configuration Submenu...

Страница 111: ...ically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port 2 Enable Disabl...

Страница 112: ...trator Password Set Administrator Password User Password Set User Password Secure Boot Customizable Secure Boot settings Security Frozen Mode Enable or disable HDD security freeze lock Disable to supp...

Страница 113: ...rm Key PK is enrolled System mode is User Deployed and CSM function is disabled Enabled Disabled Secure Boot Mode Secure Boot mode selector Custom mode enables users to change Image execution policy a...

Страница 114: ...o User Mode install all Factory Default keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Autorized Signature Database db Platform Key PK Enroll Fa...

Страница 115: ...ertificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mix...

Страница 116: ...t External Mixed Test OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin...

Страница 117: ...0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enabled or Disabled Endless...

Страница 118: ...http www tyan com 118 Boot Option Priorities Boot Option 1 Sets the system boot order Device Name Disabled Delete Boot Option Remove an EFI boot option from the boot order...

Страница 119: ...http www tyan com 119 3 8 1 Delete Boot Option Configuration Delete Boot Option Sets the system boot order Device Name Select one to Delete...

Страница 120: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Страница 121: ...http www tyan com 121 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Device Name...

Страница 122: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Страница 123: ...0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used P...

Страница 124: ...tion North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initializ...

Страница 125: ...odule specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE PIL is started PCI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory init...

Страница 126: ...oaded 0xF5 0xF7 Reserved for future AMI progress codes Recovery Error Codes 0xF8 Recovery PPI is not available 0xF9 Recovery capsule is not found 0xFA Invalid recovery capsule 0xFB 0xFF Reserved for f...

Страница 127: ...lization is started 0x71 South Bridge DXE SMM initialization is started 0x72 South Bridge devices initialization 0x73 South Bridge DXE initialization South Bridge module specific 0x74 South Bridge DXE...

Страница 128: ...s Codes section below 0xAD Ready To Boot event 0xAE Legacy Boot event 0xAF Exit Boot Services event 0xB0 Runtime Set Virtual Address MAP Begin 0xB1 Runtime Set Virtual Address MAP End 0xB2 Legacy Opti...

Страница 129: ...Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1...

Страница 130: ...lanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fa...

Страница 131: ...http www tyan com 131 BIOS Temp Sensor Name Explanation...

Страница 132: ...http www tyan com 132...

Страница 133: ...C_MAX The highest temperature of CPU0 DIMM channel C slot P0_DIMM_CH_D_MAX The highest temperature of CPU0 DIMM channel D slot P0_DIMM_CH_E_MAX The highest temperature of CPU0 DIMM channel E slot P0_D...

Страница 134: ...http www tyan com 134 SYS_FAN_10 Fan speed of SYS_FAN_10 SYS_FAN_11 Fan speed of SYS_FAN_11 SYS_FAN_12 Fan speed of SYS_FAN_12...

Страница 135: ...http www tyan com 135 NOTE...

Страница 136: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Страница 137: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Страница 138: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Страница 139: ...aster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data trans...

Страница 140: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronou...

Страница 141: ...oard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC...

Страница 142: ...omprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system compon...

Страница 143: ...ed by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Отзывы: