background image

 

http://www.tyan.com

 

 

 

 

S5630 

 Version 1.0b

 

 
Copyright 

Copyright © 2017 MiTAC International Corporation. All rights reserved. No part of 
this manual may be reproduced or translated without prior written consent from 
MiTAC International Corporation. 

 

Trademark 

All registered and unregistered trademarks and company names contained in this 
manual are property of their respective owners including, but not limited to the 
following. 

 

TYAN

®

 is a trademark of MiTAC International Corporation. 

Intel

®

 is a trademark of Intel

®

 Corporation. 

AMI, AMI BIOS are trademarks of AMI Technologies. 
Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

Winbond

®

 is a trademark of Winbond Electronics Corporation. 

 
Notice 

Information contained in this document is furnished by MiTAC International 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
MiTAC assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN

®

 products including liability or 

warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications at 
any time, without notice. In no event will MiTAC be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document. 
 
 

Содержание S5630

Страница 1: ...rosoft Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for acc...

Страница 2: ...Installing Motherboard in Chassis 34 2 9 Installing the Memory 36 2 10 Attaching Drive Cables 40 2 11 Installing Add In Cards 41 2 12 Connecting External Devices 42 2 13 Installing the Power Supply 43...

Страница 3: ...SATA Single Cable x 2 Rear IO shielding x 3 1 x S5630 Quick Installation Guide 1 x TYAN Driver CD M 2 Screw kit x2 IMPORTANT NOTE Sales samples may not come with any of the accessories listed above If...

Страница 4: ...n upgradeability All of these rich feature sets provide the S5630 with the power and flexibility to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http w...

Страница 5: ...s Controller Intel C621 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe Graphic Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspeed AST2500 Input Output USB 5 USB3 0 ports 2 at rear 2 v...

Страница 6: ...port Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature IPMI 2 0 compliant baseboard management controller BMC Supports storage over IP and remote platform flash USB 2 0 vir...

Страница 7: ...Guide Installation CD 1 TYAN installation CD S5630GMRE Specifications Processor Socket Type Q ty LGA3647 1 Supported CPU Series Intel Xeon Scalable Processor Family Thermal Design Power TDP wattage Ma...

Страница 8: ...DOM 1 Mini SAS HD 4 ports Controller Intel C621 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe Graphic Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspeed AST2500 Input Output USB 5 U...

Страница 9: ...re warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature IPMI 2 0 compliant baseboard management cont...

Страница 10: ...herboard 1 S5630 Motherboard Manual 1 Web User s manual 1 Quick Installation Guide Installation CD 1 TYAN installation CD S5630GMRE L2 Specifications Processor Socket Type Q ty LGA3647 1 Supported CPU...

Страница 11: ...CuLink connectors for 4 NVMe ports sSATA Connector 2 8 pin SATA SATA DOM 1 Mini SAS HD 4 ports Controller Intel C622 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe Graphic Connector type D Sub 15 pin Re...

Страница 12: ...ory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature I...

Страница 13: ...midity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Operating System OS supported list Please refer to our AVL support lists Package Contains Motherboard 1 S5630 Motherboard Manual 1 Web User...

Страница 14: ...onditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboar...

Страница 15: ...www tyan com 15 2 1 Board Image S5630GM2NR This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pic...

Страница 16: ...http www tyan com 16 2 2 Block Diagram S5630 Block Diagram...

Страница 17: ...http www tyan com 17 2 3 Motherboard Mechanical Drawing...

Страница 18: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Страница 19: ...30 PSMI Connector PSIMI1 14 VROC Header J51 31 24 pin Power Connector PW1 15 SATA DOM Connector SATA 3 0 signals 7Pin 2Power SATADOM2 32 4 pin FAN Connector SYS_FAN_5 16 Vertical Type A USB Connector...

Страница 20: ...Header Signal Pin Pin Signal DCD 1 2 DSR RXD 3 4 RTS TXD 5 6 CTS DTR 7 8 RI GND 9 10 KEY J29 System FAN Connector Signal Pin Pin Signal TACH1 1 2 TACH6 TACH2 3 4 TACH7 TACH3 5 6 TACH8 TACH4 7 8 TACH9...

Страница 21: ...AULT2 PWR_SW 11 12 LAN0_LED GND 13 14 LAN0_LED RESET_SW 15 16 SMBDATA GND 17 18 SMBCLK IDLED_SW 19 20 INTRUSION SYS_Air_Inlet 21 22 LAN1_LED NMI_SW 23 24 LAN1_LED DBG_HD1 TYAN Module Header Signal Pin...

Страница 22: ...SATA6G_TX_N4 3 4 GND sSATA6G_RX_N4 5 6 sSATA6G_RX_P4 GND 7 P1 VCC5 VCC5 P2 TYPEA_USB1 Vertical Type_A USB2 0 USB3 0 Connector Signal Pin Pin Signal 5V 1 2 USB2 0_DATA_N USB2 0_DATA_P 3 4 GND USB3 0_RX...

Страница 23: ...ctor Pin 1 2 3 4 5 Signal SMB_CLK SMB_DAT SMB_ALERT GND VCC3 RST_BTN1 Reset Button Pin 1 2 3 4 Signal GND GND FP_RST_BTN_N FP_RST_BTN_N CLEAR_BTN1 CMOS Clear Button You can reset the CMOS settings by...

Страница 24: ...N C1 PIN C2 GND GND PIN C3 PIN C4 SATA6G_TX_P1 SATA6G_TX_N1 PIN C5 PIN C6 GND SATA6G_TX_P3 PIN C7 PIN C8 SATA6G_TX_N3 GND PIN C9 PIN D1 NA SM_CLK PIN D2 PIN D3 GND SATA6G_TX_P0 PIN D4 PIN D5 SATA6G_TX...

Страница 25: ...PC Mode Default 2 3 eSPI Mode 3PHD6 BMC COM2 COM5 Select Jumper Signal Pin Pin Signal BMC_COM2_RXD 1 2 RXD_2 BMC_COM5_RXD 3 1 2 Normal Mode Default 2 3 Debug Mode 3PHD7 BMC COM2 COM5 Select Jumper Sig...

Страница 26: ...ERn2 A15 B15 PETn2 GROUND A16 B16 GROUND PERp3 A17 B17 PETp3 PERn3 A18 B18 PETn3 GROUND A19 B19 GROUND RESERVED A20 B20 RESERVED RESERVED A21 B21 RESERVED GROUND A22 B22 GROUND PERp4 A23 B23 PETp4 PER...

Страница 27: ...D9 PSU Throttling Function Signal Pin Pin Signal NC 1 2 Alert_Buff Alert_Buff_B 3 1 2 Normal Mode Default 2 3 enable PSU Throttling function Mode J10 CPU VR SCLK SDAT Header Signal Pin Pin Signal SMB...

Страница 28: ...D Pin Signal VCC3_AUX N860685946 State Description OFF OFF System off ON Green System Power OK 5 BMC_LED1 BMC Heart Beat LED Pin Signal VCC3_AUX N877897845 State Description OFF OFF The LED shuts off...

Страница 29: ...http www tyan com 29 8 PCH_PWOK_L ED1 CPU Power Good LED Pin Signal VCC3_AUX N859837538 State Description OFF OFF PCH Power Good Fail ON Green PCH Power Good OK...

Страница 30: ...ation Single Socket P LGA3647 for Intel Skylake CPU Follow the steps below to install the processors and heat sinks Please note that the illustrations are based on LGA3647 socket which may not look ex...

Страница 31: ...n the heatsink with the CPU socket by the guide pins and make sure the gold arrow is located in the correct direction Then place the heatsink onto the top of the CPU socket 5 Align the heatsink by the...

Страница 32: ...tp www tyan com 32 6 To secure the heatsink use a Security T30 Security Torx to tighten the screws in a sequential order 1 2 3 4 When dissembling the heatsink loosen the screws in reverse order 4 3 2...

Страница 33: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Страница 34: ...simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard w...

Страница 35: ...ad of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 36: ...h the motherboard and processor Check the TYAN Web site at http www tyan com for details of the type of memory recommended for your motherboard Support 12 DDR4 288 pin DIMM slots Support 6 memory chan...

Страница 37: ..._DIMM_D0 CPU0_DIMM_D1 CPU0_DIMM_E0 CPU0_DIMM_E1 CPU0_DIMM_F0 CPU0_DIMM_F1 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in e...

Страница 38: ...ory All installed memory will automatically be detected and no jumpers or settings need changing All memory must be of the same type and density DDR4 Memory POR Physical Ranks are used to calculate DI...

Страница 39: ...ock a DIMM socket by Press the retaining clip outwardly in the following illustration 2 Align the memory module with the socket such that the DIMM NOTCH match the KEY SLOT on the socket 3 Seat the mod...

Страница 40: ...owing illustrates how to make a SATA Cable connection If you are in need of SATA SAS cables or power adapters please contact your local sales representative 1 SATA drive cable connection 2 SATA drive...

Страница 41: ...rmly Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card...

Страница 42: ...ard LAN LED Color Definition The One 1 onboard Ethernet ports have green and Amber LEDs to indicate LAN status The chart below illustrates the different LED states 1Gbps LAN Link Activity LED Scheme D...

Страница 43: ...2V_M GND 5 6 P0_P12V_M GND 7 8 P0_P12V_M 2 14 Finishing Up Congratulations on making it this far You have finished setting up the hardware aspect of your computer Before closing up your chassis make s...

Страница 44: ...to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are...

Страница 45: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Страница 46: ...options listed below are for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Product Name It displays Product information BIOS V...

Страница 47: ...formation It displays the total memory size Memory Frequency It displays Memory frequency System Date Set the Date Use Tab to switch between Date elements Default Ranges Year 2010 2079 Months 1 12 Day...

Страница 48: ...nfigure the iSCSI parameters Intel R Virtual RAID on CPU This formset allows the user to manage Intel R Virtual RAID on CPU Trusted Computing Trusted Computing settings ACPI Settings System ACPI Param...

Страница 49: ...ole Redirection Serial Port Console Redirection Option ROM Dispatch Policy Option ROM Dispatch Policy PCI Subsystem Settings PCI PCI X and PCI Express Settings Network Stack Configuration Network Stac...

Страница 50: ...http www tyan com 50 3 3 1 iSCSI Configuration iSCSI Initiator Name The worldwide unique name of iSCSI Initiator Only IQM format is accepted Range is from 4 to 223...

Страница 51: ...IO Configuration Intel VMD technology Intel VMD for Volume Management Device on Socket 0 for CPU0 Socket 1 for CPU1 Intel VMD for Volume Management Device for PStack0 Slot 1 4 PStack1 Slot 5 8 PStack2...

Страница 52: ...ed Computing Security Device Support Enable or Disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will no...

Страница 53: ...ACPI Auto Configuration Enable or Disables BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enables or Disables System ability to Hibernate OS S4 Sleep state This option may not be ef...

Страница 54: ...www tyan com 54 3 3 5 Hardware Health Configuration Auto Fan Control Auto Fan Control help Disabled Enabled BMC Alert Beep Enable Disable BMC Alert Beep On Off PMBus support PMBus Support Disabled Ena...

Страница 55: ...55 3 3 5 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Страница 56: ...http www tyan com 56...

Страница 57: ...http www tyan com 57 3 3 6 Onboard Device Configuration Chassis Intrusion Detection Enabled When a chassis open event is detected the BIOS will display the event Disabled Enabled...

Страница 58: ...http www tyan com 58 3 3 6 AST2500 Super IO Configuration Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA Serial Port 2 Configuration Set Parameters of Serial Port 2 COMB...

Страница 59: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6...

Страница 60: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6...

Страница 61: ...tings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select dynamic time system will wake on the current time increase...

Страница 62: ...l Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the ho...

Страница 63: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with t...

Страница 64: ...rt Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled Resolu...

Страница 65: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with t...

Страница 66: ...stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent...

Страница 67: ...http www tyan com 67 3 3 8 3 Legacy Console Redirection Settings Legacy Serial Redirection Port Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM1 COM2...

Страница 68: ...r OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setti...

Страница 69: ...n sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses tw...

Страница 70: ...re if Failure If system fails to boot and this option is set to Enabled software will reset settings of this page as well as CSM page to its default values automatically Disabled Enabled PCIE_1 Empty...

Страница 71: ...or Disables 64bit capable Devices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this opt...

Страница 72: ...http www tyan com 72 3 3 10 Network Stack Configuration Network Stack Enable Disable UEFI Network Stack Enabled Disabled...

Страница 73: ...Current Boot option filter This option controls Legacy UEFI ROMs priority UEFI and Legacy Legacy only UEFI only Network Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy S...

Страница 74: ...http www tyan com 74 Other PCI devices Determines OpRom execution policy for devices other than network storage or video Do not launch UEFI legacy...

Страница 75: ...bled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support...

Страница 76: ...vice reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Hos...

Страница 77: ...http www tyan com 77 3 4 Platform Configuration PCH Configuration Displays and provides option to change the PCH Settings Server ME Configuration Configure Server ME Technology Parameters...

Страница 78: ...uration settings PCH SATA Configuration SATA devices and settings PCH sSATA Configuration sSATA devices and settings USB Configuration USB Configuration Settings PCH DFX Configuration PCH DFX Configur...

Страница 79: ...Express Root Port Enabled Disabled PCIE ASPM PCI Express Root port ASPM Setting Disable ASPM ASPM L1 ASPM Auto L1 Substates PCI Express L1 Substates settings Disabled L1 1 L1 2 L1 1 L1 2 PCIe Speed Co...

Страница 80: ...Disabled Configure SATA as Determines how SATA controller s operate AHCI RAID SATA Port 0 1 2 3 4 5 6 7 Port 0 1 2 3 4 5 6 7 Enable or Disable SATA Port Disabled Enabled Hot Plug Designates this port...

Страница 81: ...nabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid State Drive or Hard disk Drive Hard Disk Drive Solid Sta...

Страница 82: ...http www tyan com 82 5 4 1 3 PCH sSATA Configuration...

Страница 83: ...port as External SATA eSATA Disabled Enabled Spin Up Device If enabled for any of ports Staggered Spin Up will be performed and only the drives witch have this option enabled will spin up at boot Oth...

Страница 84: ...84 5 4 1 4 USB Configuration XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect...

Страница 85: ...abled ADR GPIO Select between GPIO_B or GPIO_C GPIO_B GPIO_C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Enabled Disabled Enable Disable ADR Timer Held off for DEBUG P...

Страница 86: ...http www tyan com 86 ADR timer multiplier Select proper ADR timer multiplier x1 8 24 40 56 64 72 80 88 96 x1 x8 x24 x40 x56 x64 x72 x80 x88 x96...

Страница 87: ...http www tyan com 87 5 4 2 Miscellaneous Configuration Active Video Select active video type Auto Onboard Device PCIE Device...

Страница 88: ...http www tyan com 88 5 4 3 Server ME Configuration Read only...

Страница 89: ...e Configuration Displays the provides option to change the Common RefCode Settings Memory Configuration Displays and provides option to change the Memory Settings IIO Configuration Displays and provid...

Страница 90: ...x CPUID Value Limit This should be enabled in order to boot legacy OSes that cannot support CPUs with extended CPUID functions Disabled Enabled Execute Disable Bit When disabled forces the XD feature...

Страница 91: ...d Lock Chipset Lock or Unlock chipset Disabled Enabled Hardware Prefetcher MLC Streamer Prefetcher MSR 1A4h Bit 0 Enabled Disabled Adjacent Cache Prefetch MLC Spatial Prefetcher MSR 1A4h Bit 1 Enabled...

Страница 92: ...High Base 56T 40T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up to 32xgranularity Per stack mmioh resource assi...

Страница 93: ...this feature Auto Sets it to the MRC default setting current default is Enable Auto POR Disable Memory Frequency Maximum Memory Frequency selections in Mhz Do not select Reserved Auto 1866 2133 2400 2...

Страница 94: ...http www tyan com 94 5 5 3 1 Memory Topology Read only...

Страница 95: ...Mirror Mode 1LM Mirror Mode 2LM Mirror TAD0 Enable Mirror on entire memory for TAD0 Enabled Disabled Enable Partial Mirror Partial mirror mode will enable the required size of memory to be mirrored If...

Страница 96: ...ctable Error Threshold 1 32767 used for sparing tagging and leaky bucket 10 SDDC Plus One Enable Disable SDDC Plus One Disabled Enabled ADDDC Sparing Enable Disable ADDDC Sparing Disabled Enabled Patr...

Страница 97: ...n menu Intel VMD Technology Press Enter to bring up the Intel VMD for Volume Management Device Configuration menu PCIe Hot Plug Enable Disable PCIe Hot Plug globally Disabled Enabled Auto Manual PCIe...

Страница 98: ...http www tyan com 98 PCIe Access Control Services Enable or disable Access Control Services ACS in PCIe Downstream Switch Port Disabled Enable...

Страница 99: ...furcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 Auto IDU2 IIO PCIe Br3 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 Auto Socket 0 PcieBr1D00F0 Port 1...

Страница 100: ...Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 5A Socket 0 PcieBr3D02F0 Port 3C Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 5A Socket 0 PcieBr3D02F0 Port 3D...

Страница 101: ...to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable This optio...

Страница 102: ...PCIe port Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled I...

Страница 103: ...s used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable Thi...

Страница 104: ...downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state Disabled Enabled 5 5 5 1 3 Socket 0 PcieBr2D00F0 Port 3B 3C 3D PCI E Port In auto mode th...

Страница 105: ...abled PCI E Port Link This option disables the link so that the no training occurs but the CFG space is still active Enabled Disabled Link Speed Choose Link Speed for this PCIe port Auto Gen 1 2 5 GT...

Страница 106: ...ed to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled PCI E Port Link This option disab...

Страница 107: ...L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state Disabled Enabled 5 5 5 2 Intel VT for Directed I O VT d Intel VT for D...

Страница 108: ...http www tyan com 108 5 5 5 3 Intel VMD Technology...

Страница 109: ...Volume Management Device Technology in this Stack Disabled Enabled Intel VMD for Volume Management Device VMD Config for PStack1 Enable Disable Intel Volume Management Device Technology in this Stack...

Страница 110: ...ion CPU P State Control P State Control Configuration Sub Menu include Turbo XE and ete Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting Package C State Contr...

Страница 111: ...state that the BIOS will set before OS hand off Max Performance Max Efficient Set by Intel Node Manager Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Enabled Disabled Turbo Mode E...

Страница 112: ...ore Ratio Multiplier 23 5 5 5 4 2 Hardware PM State Control Hardware P States Disable Hardware chooses a P state based on OS Request Legacy P States Native Mode Hardware chooses a P state based on OS...

Страница 113: ...rol CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Disabled Enabled Auto Enhanced Halt State C1E Core C1E auto promotion Control Takes effect after reboot Disabled Enabled OS ACPI Cx Report...

Страница 114: ...http www tyan com 114 5 5 5 4 4 Package C State Control Package C State Package C State limit C0 C1 state C2 state C6 non Retention state C6 Retention state No Limit Auto...

Страница 115: ...http www tyan com 115 5 5 5 4 5 CPU T State Control Software Controlled T States Enable Disable Software Controlled T States Disabled Enabled...

Страница 116: ...figure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing Reset Power Down Power Cycle OS Watchdog Timer If enabled starts a BIOS timer which...

Страница 117: ...minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog timer is disabled Do Nothing Reset Power Down Power Cycle BM...

Страница 118: ...nts is set to Disabled the following items are read only Erase SEL Choose options for erasing SEL No Yes on next reset Yes on every reset When SEL is Full Choose options for reactions to a full SEL Do...

Страница 119: ...http www tyan com 119 5 6 2 BMC Network Configuration...

Страница 120: ...parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Configuration Ad...

Страница 121: ...key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm Ne...

Страница 122: ...activated when Platform Key PK is enrolled System mode is User Deployed and CSM function is disabled Disabled Enabled Secure Boot Mode Secure Boot mode selector Standard Custom In Custom mode Secure...

Страница 123: ...Press Yes to install factory default keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 has of the binary into Authorized signature Database db Save All Secure Boot Variabl...

Страница 124: ...Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 bin 2...

Страница 125: ...256 Key source Default External Mixed Test Set New Append OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X50...

Страница 126: ...0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Wait for ESC If Error Wait for ESC key...

Страница 127: ...http www tyan com 127 Boot Option Priorities Boot Option 1 3 Select the first second boot device Device Name Disabled Network Device BBS Priorities Set the order of the legacy devices in this group...

Страница 128: ...http www tyan com 128 5 8 1 Network Device BBS Priorities Boot Option 1 Set the system boot order Device Name Disabled...

Страница 129: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Страница 130: ...http www tyan com 130 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Read only...

Страница 131: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Страница 132: ...0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used P...

Страница 133: ...tion North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initializ...

Страница 134: ...odule specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE PIL is started PCI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory init...

Страница 135: ...oaded 0xF5 0xF7 Reserved for future AMI progress codes Recovery Error Codes 0xF8 Recovery PPI is not available 0xF9 Recovery capsule is not found 0xFA Invalid recovery capsule 0xFB 0xFF Reserved for f...

Страница 136: ...lization is started 0x71 South Bridge DXE SMM initialization is started 0x72 South Bridge devices initialization 0x73 South Bridge DXE initialization South Bridge module specific 0x74 South Bridge DXE...

Страница 137: ...s Codes section below 0xAD Ready To Boot event 0xAE Legacy Boot event 0xAF Exit Boot Services event 0xB0 Runtime Set Virtual Address MAP Begin 0xB1 Runtime Set Virtual Address MAP End 0xB2 Legacy Opti...

Страница 138: ...Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1...

Страница 139: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Страница 140: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion i...

Страница 141: ...n is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed...

Страница 142: ...http www tyan com 142 BIOS Temp Sensor Name Explanation...

Страница 143: ...CPU0 MC1 DIM channel E slot P0_MC1_DIM_CH_F The highest temperature of CPU0 MC1 DIM channel F slot PCH_Temp Temperature of the PCH SYS_Air_Intlet Temperature of the SYS_Air_Inlet Area MB_Air_Inlet Tem...

Страница 144: ...http www tyan com 144 NOTE...

Страница 145: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Страница 146: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Страница 147: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Страница 148: ...aster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data trans...

Страница 149: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronou...

Страница 150: ...oard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC...

Страница 151: ...omprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system compon...

Страница 152: ...ed by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Отзывы: