background image

 

 

 

 

S5560 

 Version 1.0

 

 
Copyright 

Copyright © 2021 MiTAC International Corporation. All rights reserved. No part of 
this manual may be reproduced or translated without prior written consent from 
MiTAC International Corporation. 

 

Trademark 

All registered and unregistered trademarks and company names contained in this 
manual are property of their respective owners including, but not limited to the 
following. 

 

TYAN

®

 is a trademark of MiTAC International Corporation. 

Intel

®

 is a trademark of Intel

®

 Corporation. 

AMI, AMI BIOS are trademarks of AMI Technologies. 
Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

Winbond

®

 is a trademark of Winbond Electronics Corporation. 

 
Notice 

Information contained in this document is furnished by MiTAC International 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
MiTAC assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN

®

 products including liability or 

warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications at 
any time, without notice. In no event will MiTAC be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document. 
 
 
 
 
 
 
 
 
 
 
 

Содержание S5560

Страница 1: ...poration Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accuracy and...

Страница 2: ...ps on Installing Motherboard in Chassis 27 2 7 Installing the Memory 29 2 8 Attaching Drive Cables 32 2 9 Installing Add In Cards 33 2 10 Connecting External Devices 34 2 11 Installing the Power Suppl...

Страница 3: ...d contain the following 1 x S5560 Motherboard 1 x Rear IO shielding 1 x S5560 Quick Installation Guide 2 x SATA Single Cable 1 x M 2 Latch IMPORTANT NOTE Sales sample may not come with the accessory l...

Страница 4: ...lity All of these rich feature sets provide the S5560 with the power and flexibility to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http www tyan com...

Страница 5: ...1 22110 2280 by PCIe Gen 3 interface Graphic VGA Connector type 1 VGA Resolution Up to 1920x1200 60Hz Chipset Aspeed AST2600 Graphic Display Port Connector type 1 Display port 1 2 Resolution Up to 409...

Страница 6: ...support Console Redirection User Configurable FAN PWM Duty Cycle SMBIOS 3 3 PnP Wake on LAN ACPI 6 2 ACPI sleeping states S0 S5 Physical Dimension Form Factor Micro ATX Board Dimension 9 6 x 9 6 243 8...

Страница 7: ...ts PCIe 1 PCIe Gen 4 x16 slot 3 w x8 link from CPU 1 PCIe Gen 4 x8 open end slot 2 w x8 link from CPU 1 PCIe Gen 3 x8 open end slot 1 w x2 link from PCH LAN Q ty Port 2 10GbE ports 1 GbE dedicated for...

Страница 8: ...mory chipset power supply Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2600 AST2600 iKVM Feature 24 bit high quality video compression Supports storage over IP and...

Страница 9: ...C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Operating System OS supported list Please refer to our AVL support lists Package Contains Motherboard...

Страница 10: ...st conditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the mother...

Страница 11: ...11 http www tyan com 2 1 Board Image S5560GM2NRE 2T HE...

Страница 12: ...12 http www tyan com S5560GM2NRE 2T This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture...

Страница 13: ...13 http www tyan com 2 2 Block Diagram S5560 Block Diagram...

Страница 14: ...14 http www tyan com 2 3 Motherboard Mechanical Drawing...

Страница 15: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Страница 16: ...5 10 COM2 J64 29 Reset Button SW1 11 BMC Debug J63 30 SYS_FAN_4 J20 12 System Fan Header J52 31 Power Button SW2 13 SATA SGPIO J10 32 SYS_FAN_3 J56 14 IPMB Header J24 33 SYS_FAN_2 J55 15 M 2 Connector...

Страница 17: ...to connect the cooling fan to your motherboard to keep the system stable and reliable Note A 4 pin fan is required for fan support 4pin Control J52 System Fan Header Signal Pin Pin Signal TACH1 1 2 T...

Страница 18: ...nnectors SATA4 SATA5 Name TYPE 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND P1 P5V P2 GND Connects to the Serial ATA ready drives via the Serial ATA cable J24 IPMB Connector Signal Pin Pin Signal IPMB_DA...

Страница 19: ..._ ACTLED J5 36 pin Vertical Mini SAS HD Connector SATA 0 3 Signal Pin Pin Signal GND A3 C3 GND RXA0_DP B4 D4 TXA0_DP RXA0_DN B5 D5 TXA0_DN RXA1_DP A6 C6 GND RXA1_DN A4 C4 TXA1_DP GND A5 C5 TXA1_DN TP...

Страница 20: ...Signal P5V_AUX_TYPEA 1 3 USB2_PCH_P9_ESD_DP USB2_PCH_P9_ESD_DN 2 4 GND J66 TYAN Debug Card Header Signal Pin Pin Signal P3V3_AUX 1 2 ESPI_CS0_N ESPI_IO0 3 4 ESPI_IO1 5 6 RST_ESPI_RESET_N ESPI_IO2 7 8...

Страница 21: ...30 NC PE_RX_1_P 31 32 NC GND 33 34 NC PE_TX_1_N 35 36 NC PE_TX_1_P 37 38 DEVSLP GND 39 40 SMB_M2_SSD_P1V8_SCL PE_RX_0_N 41 42 SMB_M2_SSD_P1V8_SDA PE_RX_0_P 43 44 IRQ_SMB_M2_SSD_ALERT_P1 V8_N GND 45 4...

Страница 22: ...umper from Pin_1 and Pin_2 Default setting 3 Move the jumper cap to close Pin_2 and Pin_3 for several seconds to Clear CMOS 4 Put jumper cap back to Pin_1 and Pin_2 Default setting 5 Reconnect power c...

Страница 23: ...for damage as a result of operating an unsupported configuration Processor Installation for Intel E 2300 and Pentium CPU Follow the steps below to install the processors and heat sinks Please note tha...

Страница 24: ...24 http www tyan com 3 Open the CPU socket cover 4 Install the processor and make sure the gold arrow is located in the right direction 5 Close the CPU socket cover 6 Close the socket lever...

Страница 25: ...ated processor is dangerous to the motherboard For the safest method of installation and information on choosing the appropriate heat sink using heat sinks validated by Intel Please refer to the Intel...

Страница 26: ...26 http www tyan com 3 Secure the heat sink screws 4 Connect the fan cable to complete the installation...

Страница 27: ...simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard w...

Страница 28: ...ad of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 29: ...ck the TYAN Web site at http www tyan com for details of the type of memory recommended for your motherboard Supports up to 128GB DDR4 Unbuffered ECC UDIMM 3200 memory Supports 2 DIMM slots per channe...

Страница 30: ...MC0_DIM_CH_A1 P0_MC0_DIM_CH_B0 P0_MC0_DIM_CH_B1 01 02 03 04 05 06 07 08 NOTE 1 Supported DDR4 ECC and Non ECC UDIMM 2 The memory slots of DDR4 channels should be populated on a farthest first fashion...

Страница 31: ...ock a DIMM socket by Press the retaining clip outwardly in the following illustration 2 Align the memory module with the socket such that the DIMM NOTCH match the KEY SLOT on the socket 3 Seat the mod...

Страница 32: ...el Connections for the drives are very simple There is no need to set Master Slave jumpers on SATA drives If you are in need of SATA SAS cables or power adapters please contact your place of purchase...

Страница 33: ...any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card TIP It s a good pr...

Страница 34: ...en and yellow LEDs to indicate LAN status The chart below illustrates the different LED states 10 Mbps 100 Mbps 1Gbps LAN Link Activity LED Scheme Left LED Right LED Linked 10 Mbps Link Green Solid On...

Страница 35: ...me Left LED Link Activity Right LED Speed No Link OFF OFF 100 Mbps Link Solid Green Solid Green Active Blinking Green Solid Green 1000 Mbps Link Solid Green Solid Yellow Active Blinking Green Solid Ye...

Страница 36: ...D 2 6 12 Vdc GND 3 7 12 Vdc GND 4 8 12 Vdc 2 12 Finishing Up Congratulations on making it this far You have finished setting up the hardware aspect of your computer Before closing up your chassis make...

Страница 37: ...rent at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basi...

Страница 38: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Страница 39: ...e for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Memory Information This displays the total memory size Access Level Read o...

Страница 40: ...ion Trusted Stack settings S5 RTC Wake Settings Enable system to wake from S5 using RTC alarm Serial Port Console Redirection Serial Port Console Redirection USB Configuration USB Configuration Parame...

Страница 41: ...Option ROM Dispatch Policy Option ROM Dispatch Parameters Redfish Host Interface Settings Redfish Host Interface Parameters Tls Auth Configuration Press Enter to select Tls Auth Configuration iSCSI C...

Страница 42: ...ems are available when Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV4 PXE boot option will not be created Disabled Enabled Ipv4 HTTPS Support Enable Ipv...

Страница 43: ...Enable Ipv6 HTTP Boot Support If disabled IPV6 HTTP boot option will not be created Disabled Enabled PXE boot wait time Wait time to press ESC key to abort the PXE boot 0 Media detect count Number of...

Страница 44: ...l wake on the hr min sec specified Select dynamic time system will wake on the current time increase minute s Disabled Fixed time Dynamic time When set to Fixed Time wake up hour Select 0 23 for examp...

Страница 45: ...nt Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the host computer which the user is u...

Страница 46: ...VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes VT UTF8 VT100 VT100 ANSI Bits per Second Select serial port transmission sp...

Страница 47: ...re more than 1 stop bit 1 2 Flow Control Flow Control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Onc...

Страница 48: ...VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes VT UTF8 VT100 VT100 ANSI Bits per Second Select serial port transmission sp...

Страница 49: ...re more than 1 stop bit 1 2 Flow Control Flow Control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Onc...

Страница 50: ...through a serial port COM1 COM2 Terminal Type EMS VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setti...

Страница 51: ...a if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to se...

Страница 52: ...bled Enabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Disabled Enabled USB Mass Storage Driver Support...

Страница 53: ...Hub descriptor Auto Manual NOTE Device power up delay in seconds is available when Device power up delay is set to Manual AMI Virtual CDROM0 1 00 Mass storage device emulation type Auto enumerates de...

Страница 54: ...disable onboard VGA Enabled Disabled LAN1 LAN Enable Disable control function Enabled Disabled LAN2 LAN Enable Disable control function Enabled Disabled Chassis Intrusion Detection Enabled When a cha...

Страница 55: ...55 http www tyan com 3 3 6 AST2600 Device Configuration Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA Serial Port 2 Configuration Set Parameters of Serial Port 2 COMB...

Страница 56: ...Serial Port Enable or disable Serial Port COM Enabled Disabled NOTE The following items will appear when Serial Port set to Enabled Change Settings Select an optimal settings for Super IO Device Auto...

Страница 57: ...3 3 6 2 Serial Port 2 Configuration Serial Port Enable or disable Serial Port COM Enabled Disabled Change Settings Select an optimal setting for Super IO Device Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 IO 3E8...

Страница 58: ...Speed Control BIOS setting from Manual to Full Speed when installing the Nvidia GeForce Quardro GPU and any VGA card PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 NOTE This item is available when F...

Страница 59: ...enu will appear PMBus Support Default setting is Disabled Number of PSU Number of PSU 1 2 3 3 7 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will se...

Страница 60: ...60 http www tyan com...

Страница 61: ...ted Computing Security Device Support Enable or Disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will n...

Страница 62: ...62 http www tyan com 3 3 9 NVMe Configuration...

Страница 63: ...3 http www tyan com 3 3 10 PCI Subsystem Above 4G Decoding Enables or Disables 64bit capable Devices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Disabled Enable...

Страница 64: ...ww tyan com 3 3 10 1 PCI Express Settings Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes 40...

Страница 65: ...2 Option ROM Enable or Disable LAN2 Option ROM Enabled Disabled PCIE 1 Option ROM Enable or Disable Option ROM execution for selected Slot Disabled Enabled PCIE 2 Option ROM Enable or Disable Option R...

Страница 66: ...ce Configuration Redfish Enable Disable AMI Redfish Enabled Disabled Authentication mode Select authentication mode Basic Authentication Session Authentication IP address Enter IP address IP Mask addr...

Страница 67: ...67 http www tyan com 3 3 13 Tls Auth Configuration Server CA Configuration Press Enter to configure Server CA Client Cert Configuration Press Enter to configure Client Cert...

Страница 68: ...68 http www tyan com 3 3 13 1 Server CA Configuration Enroll Cert Press Enter to enroll cert Delete Cert Press Enter to delete cert...

Страница 69: ...nroll Cert Enroll Cert Using File Enroll Cert Using File Cert GUID Input digit character in 11111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Commit Changes and Exit Discard Changes...

Страница 70: ...70 http www tyan com 3 3 13 1 2 Delete Cert FE9C6606 8B49 44A3 8B6B DEA3A0E032 GUID for CERT Disabled Enabled...

Страница 71: ...14 iSCSI Configuration Attempt Priority Change the priority using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Host iSCSI Configuration H...

Страница 72: ...ty Configuration Attempt Priority Change the priority using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order lists Host Attempt Redfish Attempt Com...

Страница 73: ...n xxx xxx ranges from 4 to 223 Add an Attempt Add an Attempt Attempt 1 MAC A0 42 3F 4D 46 1A PFA Bus 1 Dev 0 Func 0 iSCSI mode Enabled IP version IPv4 Delete Attempts Delete one or more attempts Chang...

Страница 74: ...74 http www tyan com 3 3 14 2 1 Add an Attempt MAC xx xx xx xx xx xx Intel Ethernet Converged Network Connection PFA Bus 1 Dev 0 Func 0...

Страница 75: ...ttempt 2 Attempt iSCSI Mode Disabled Enabled Enabled for MPIO Disabled Enabled Enabled for MPIO Internet Protocol Initiator IP address is system assigned in IP6 mode In Autoconfigure mode iSCSI driver...

Страница 76: ...in dotted decimal notation Initiator Subnet Mask Enter IP address in dotted decimal notation Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Onl...

Страница 77: ...d for MPIO Disabled Enabled Enabled for MPIO Internet Protocol Initiator IP address is system assigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to connect iSCSI target via IPv4 stac...

Страница 78: ...DEEFF to OABBCCF07901 by input F07901 Enable DHCP Enable DHCP Disabled Enabled Initiator IP Address Enter IP address in dotted decimal notation Initiator Subnet Mask Enter IP address in dotted decimal...

Страница 79: ...4 2 3 Delete Attempts Attempt 1 MAC xx xx xx xx xx xx PFA Bus 1 Dev 0 Func 0 iSCSI mode Enabled IP version IPv4 Disabled Enabled Commit Changes and Exit Commit Changes and Exit Discard Changes and Exi...

Страница 80: ...tempt Order Change the order of Attempts using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Attempt 1 Commit Changes and Exit Commit Chang...

Страница 81: ...ttp www tyan com 3 3 15 MAC xxxxxxxxxxxx IPv4 Network Configuration Configured Indicate whether network address configured successfully or not Disabled Enabled Save Changes and Exit Save Changes and E...

Страница 82: ...82 http www tyan com 3 3 16 MAC xxxxxxxxxxxx IPv6 Network Configuration Enter Configuration Menu Press ENTER to enter configuration menu for IPv6 configuration...

Страница 83: ...DAD Transmit Count The number of consecutive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address De...

Страница 84: ...64 New Gateway addressed Gateway IP address can only be configured under manual policy e g 2002 3 Separate the IP address with blank space to configure more than one address New DNS addresses DNS add...

Страница 85: ...hernet Converged Network Adapter X550 T2 Configuration Firmware Image Properties View device firmware version information NIC Configuration Click to configure the network device port Blink LEDs Blink...

Страница 86: ...86 http www tyan com 3 3 17 1 Firmware Image Properties Configuration...

Страница 87: ...f 10 Mbps Full 100 Mbps Half 100Mbps Full Wake On LAN Specifies the port speed used for the selected boot protocol Enables power on of the system via LAN Note that configuring Wake on LAN in the opera...

Страница 88: ...88 http www tyan com 3 4 CPU Menu CPU Configuration CPU Configuration Parameters CPU Power Management Control CPU Power Management Control Options...

Страница 89: ...abled Enabled Active Processor Cores Number of cores to enable in each processor package All 1 2 3 4 5 6 7 Enable Intel TXT Enable Intel TXT Disabled Enabled Intel VMX Virtualization Technology When e...

Страница 90: ...cycle to take effect Disabled Enabled NOTE The following items will be available when Intel Trusted Execution must be set to Enabled Alias Check Request Enables Txt Alias Checking capability Changes r...

Страница 91: ...4bit no change in owner epoch change to new random owner epoch and manually entered by user After generating new epoch via Change to New Random Owner EPOCHs the selection reverts back to No change in...

Страница 92: ...ance mode Select the performance state that the BIOS will set starting from reset vector Max Battery Max Non Turbo Performance Turbo Performance Intel Speed Shift Technology Enable Disable Intel Speed...

Страница 93: ...states when it s not 100 utilized Enhanced C States Enable Disable C1E When enabled CPU will switch to minimum speed when all cores enter C states Disabled Enabled Package C State Limit Maximum Packa...

Страница 94: ...94 http www tyan com 3 5 Chipset Menu North Bridge System Agent SA parameters South Bridge PCH parameters...

Страница 95: ...n Memory Configuration Memory Configuration Parameters Graphics Configuration Graphics Configuration DMI OPI Configuration Control various DMI functions PCI Express Configuration PCI Express Configura...

Страница 96: ...96 http www tyan com 3 5 1 1 Memory Configuration DDR Speed Control DDR Frequency control Auto Manual ECC Support Enable disable DDR Ecc Support Disabled Enabled...

Страница 97: ...tyan com 3 5 1 2 Graphics Configuration Primary Display Select which Graphics device should be Primary Display Auto IGFX PEG PCH PCIe Internal Graphics Enable Disable Internal Graphics IGFX Auto Disab...

Страница 98: ...98 http www tyan com 3 5 1 3 DMI OPI Configuration DMI Max Link Speed Set DMI Speed Gen1 Gen2 Gen3 Gen1 Gen2 Gen3 DMI Gen3 ASPM DMI Gen3 ASPM Support Disabled Auto ASPM L0s ASPM L1 ASPM L0sL1...

Страница 99: ...99 http www tyan com 3 5 1 4 PCI Express Configuration PCI Express Root Port 1 4 PCI Express Root Port Settings...

Страница 100: ...Express Root Port 1 2 3 4 Control the PCI Express Root Port Disabled Enabled ASPM Set the ASPM level Force L0s Force all links to L0s States AUTO BIOS auto configure DISABLE Disables ASPM Disabled L0s...

Страница 101: ...SATA And RSTe Configuration SATA Device Options Settings HD Audio Configuration HD Audio Subsystem Configuration Settings PCI Express Configuration PCI Express Configuration settings Enabled Disabled...

Страница 102: ...102 http www tyan com 3 5 2 1 Server ME Configuration...

Страница 103: ...bled Enabled SATA Mode Selection Determines how SATA controllers operate AHCI RAID Serial ATA Port0 1 2 3 4 5 6 7 Hot Plug Designates this port as Hot Pluggable Disabled Enabled SATA Device Type Ident...

Страница 104: ...http www tyan com 3 5 3 HD Audio Configuration HD Audio Control Detection of the HD Audio device Disabled HDA will be unconditionally disabled Enabled HDA will be unconditionally enabled Disabled Enab...

Страница 105: ...yan com 3 5 4 PCI Express Configuration DMI Link ASPM Control The control of Active State Power Management of the DMI Link Disabled L0s L1 L0sL1 Auto PCI Express Root Port 1 5 9 11 21 PCI Express Root...

Страница 106: ...tion PCI Express Root Port 1 5 9 11 21 Control the PCI Express Root Port Disabled Enabled ASPM Set the ASPM Level Force L0s Force all links to L0s State AUTO BIOS auto configure DISABLE Disables ASPM...

Страница 107: ...able when FRB 2 Timer is set to Enabled FRB 2 Timer timeout Enter value Between 3 to 6 min for FRB 2 Timer Expiration value Not available if FRB 2 Timer is disabled 3 minutes 4 minutes 5 minutes 6 min...

Страница 108: ...d Timer timeout Configure the length of the OS Boot Watchdog Timer Not available if OS Boot Watchdog timer is disabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the...

Страница 109: ...le event logging for error progress codes during boot Disabled Enabled Erase SEL Choose options for erasing SEL No Yes On next reset Yes On every reset Log EFI Status Codes Disable the logging of EFI...

Страница 110: ...ally by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp Management Port 2 Enable Disable BMC Share NIC Enabled Disabled Co...

Страница 111: ...111 http www tyan com 3 6 3 BMC User Settings Add User Press Enter to Add a user Delete User Press Enter to Delete a user Change User Settings Press Enter to change User Settings...

Страница 112: ...ord Enter New Password to change Password at least 8 characters User Access Enable Disable the BMC User s Access Enabled Disabled Channel No Enter BMC Channel Number N A 1 8 User Privilege Limit Enter...

Страница 113: ...113 http www tyan com 3 6 3 2 Delete User User Name Enter BMC User Name User Password Enter New Password to change Password at least 8 characters...

Страница 114: ...ssword at least 8 characters Change User Password Enter New Password to change Password at least 8 characters User Access Enable Disable the BMC User s Access Enabled Disabled Channel No Enter BMC Cha...

Страница 115: ...trator Password Set Administrator Password User Password Set User Password Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function Disabled Enabled Sec...

Страница 116: ...Disabled Secure Boot Mode Secure Boot mode options Standard or Custom In Custom mode Secure Boot Policy variables can be configured by a physically present user without full authentication Standard C...

Страница 117: ...ser Mode Install factory default Secure Boot key databases Reset To Setup Mode Delete all Secure Boot key databases from NVRAM Export Secure Boot variable Copy NVRAM content of Secure Boot variable to...

Страница 118: ...enu Set New Key Append Key Key Exchange Keys Enroll factory Defaults or load the keys from a file with 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 b...

Страница 119: ...s or load the keys from a file with 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 bin 2 Authenticated UEFI Variable Key Vendor C...

Страница 120: ...umLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Wait For ESC If Error Wait for ESC key to be pressed if error occurs Disabled Enab...

Страница 121: ...n to the boot order Delete Boot Option Remove an EFI boot option from the boot order 3 8 1 Add New Boot Option Configuration Add boot option Specify name for new boot option Path for boot option Enter...

Страница 122: ...122 http www tyan com 3 8 2 Delete Boot Option Configuration Delete Boot Option Sets the system boot order Select one to Delete Device Name...

Страница 123: ...it Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Sa...

Страница 124: ...Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup opti...

Страница 125: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Страница 126: ...DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used Progress C...

Страница 127: ...nitialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initialization South Bridge module specific 0x1D 0x2A O...

Страница 128: ...atible memory speed 0x51 Memory initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usab...

Страница 129: ...x63 CPU DXE initialization is started 0x64 CPU DXE initialization CPU module specific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 CPU DXE initi...

Страница 130: ...93 PCI Bus Hot Plug Controller initialization 0x94 PCI Bus Enumeration 0x95 PCI BUS Request Resources 0x96 PCI Bus Assign Resources 0x97 Console output devices connect 0x98 Console Input devices conne...

Страница 131: ...error 0xD1 North Bridge initialization error 0xD2 South Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error Out of Resources 0xD5...

Страница 132: ...onfig Error 0xDD1A DCC Initialization 0xDD9A DCC Initialization Error 0xDD1B Fast boot permitted 0xDD9B Fast boot permitted Error 0xDD1C Restore non training values 0xDD9C Restore non training values...

Страница 133: ...0xDDAF Read Timing Centering Error 0xDD30 DIMM ODT Training 0xDDB0 DIMM ODT Training Error 0xDD31 Early Write Timing Centering 2D 0xDDB1 Early Write Timing Centering 2D Error 0xDD32 Write Drive Streng...

Страница 134: ...n Training Error 0xDD42 Save MC Values 0xDDC2 Save MC Values Error 0xDD43 Restore Training Values 0xDDC3 Restore Training Values Error 0xDD44 Rank Margin Tool 0xDDC4 Rank Margin Tool Error 0xDD45 Writ...

Страница 135: ...Read Voltage Centering 0xDDD7 Read Voltage Centering Error 0xDD58 Check Margin for Retrain 0xDDD8 Check Margin for Retrain Error 0xDD59 Rank Margin Tool Bit 0xDDD9 Rank Margin Tool Bit Error 0xDD5A M...

Страница 136: ...0xDD6C Command Drive Strength and Equalization 2D 0xDDEC Command Drive Strength and Equalization 2D Error 0xDD6D DIMM CA ODT Training 0xDDED DIMM CA ODT Training Error 0xDD6E Write TCO DqsP N Bypass...

Страница 137: ...Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the motherboa...

Страница 138: ...ver during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion is signifi...

Страница 139: ...n is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed...

Страница 140: ...140 BIOS Temp Sensor Name Explanation...

Страница 141: ...0_MC0_DIM_CH_B Slot P_MOSFET Temperature of the CPU _MOSFET SYS_Air_Inlet Temperature of the SYS_Air_Inlet Area SYS_Air_Outlet Temperature of the SYS_Air_Outlet Area MB_Air_Inlet Temperature of the MB...

Страница 142: ...142 NOTE...

Страница 143: ...nd parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in greater...

Страница 144: ...of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on eight diff...

Страница 145: ...ry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form factors are the AT and ATX Global timer onboard hardware ti...

Страница 146: ...not PCI refers to the type of bus used by these modes to communicate with the CPU PCI to PCI Bridge allows you to connect multiple PCI devices onto one PCI slot Pipeline burst SRAM a fast secondary ca...

Страница 147: ...is transmitted in serial form one bit after another SCSI Interrupt Steering Logic SISL Architecture that allows a RAID controller such as AcceleRAID 150 200 or 250 to implement RAID on a system board...

Страница 148: ...lay standard V SYNC controls the vertical scanning properties of the monitor ZCR Zero Channel RAID PCI card that allows a RAID card to use the onboard SCSI chip thus lowering cost of RAID solution ZIF...

Страница 149: ...ive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system components to k...

Страница 150: ...ning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the recei...

Отзывы: