background image

 

http://www.tyan.com

 

1

 

 

 

S5515 

 Version 1.1a

 

 
Copyright 

Copyright © 2012 MiTAC International Corporation. All rights reserved. No part of 
this manual may be reproduced or translated without prior written consent from 
MiTAC International Corporation. 

 

Trademark 

All registered and unregistered trademarks and company names contained in this 
manual are property of their respective owners including, but not limited to the 
following. 

 

TYAN

®

 is a trademark of MiTAC International Corporation. 

Intel

®

 is a trademark of Intel

®

 Corporation. 

AMI, AMI BIOS are trademarks of AMI Technologies. 
Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

Winbond

®

 is a trademark of Winbond Electronics Corporation. 

 
Notice 

Information contained in this document is furnished by MiTAC International 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
MiTAC assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN

®

 products including liability or 

warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications at 
any time, without notice. In no event will MiTAC be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document. 
 
 

Содержание S5515

Страница 1: ...rosoft Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for acc...

Страница 2: ...http www tyan com 2...

Страница 3: ...Material 25 2 6 Tips on Installing Motherboard in Chassis 26 2 7 Installing the Memory 28 2 8 Attaching Drive Cables 32 2 9 Installing Add In Cards 33 2 10 Connecting External Devices 34 2 11 Installi...

Страница 4: ...rboard 6 x SATA Cable 1 x COM dual port Bracket Cable 1 x USB dual port Bracket Cable 1 x IO shielding 1 x S5515 User s manual 1 x S5515 Quick reference guide 1 x TYAN Driver CD IMPORTANT NOTE Sales s...

Страница 5: ...ower and flexibility to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http www tyan com There you can find all the information on all TYAN products as w...

Страница 6: ...INE_OUT MIC_IN connectors RJ 45 2 GbE ports Power SSI ATX 24 pin 4 pin power connectors Front Panel 1 2x12 pin SSI front panel header Input Output SATA 4 SATA II and 2 SATA III connectors Chipset Nuvo...

Страница 7: ...C RoHS RoHS 6 6 Compliant Yes Motherboard 1 S5515 Motherboard Manual 1 User s manual 1 Quick Ref Guide Installation CD 1 TYAN installation CD I O Shield 1 I O Shield SATA 6 SATA signal cables Package...

Страница 8: ...http www tyan com 8 NOTE...

Страница 9: ...uch a safely grounded object to release static charge i e power supply case For the safest conditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do no...

Страница 10: ...tp www tyan com 10 2 1 Board Image S5515 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pictu...

Страница 11: ...http www tyan com 11 2 2 Block Diagram S5515 Block Diagram...

Страница 12: ...of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please refer to the above placement for memor...

Страница 13: ...J82 FP 82579 LAN Activity LED Header J76 FP 82583 LAN Activity LED Header INT_SPKR Internal Speaker Header J4 CMOS Clear Jumper F_AUDIO1 Front Audio Connector U_SPI1 BIOS SPI ROM Header FCFH1 Chassis...

Страница 14: ...http www tyan com 14 J35 COM1 COM4 COM2 COM3 CPU Fan J2 Front Fan Rear Fan U_SPI1...

Страница 15: ...COM4 COM Port Header Signal Pin Pin Signal DCD 1 2 DSR RXD 3 4 RTS TXD 5 6 CTS DTR 7 8 RI 1 2 10 9 GND 9 10 KEY Pin J35 APS Header Signal Pin Pin Signal 3VSB 1 2 SLP_S3 SLP_S4 3 4 3VSB SLP_A 5 6 SLP_S...

Страница 16: ...http www tyan com 16 INT SPKR J20 J82 J76 FCFH1 F AUDIO1...

Страница 17: ...header to trigger the system chassis intrusion alarm J76 82583 LAN Activity LED Header Signal Pin Pin Signal 1 VCC3 1 2 82583_LED_ACT J82 82579 LAN Activity LED Header Signal Pin Pin Signal 1 VCC3 1 2...

Страница 18: ...http www tyan com 18 J81 J13 LED1 FP USB 1 2 J98 J97 J96 J95 J94 SATA 2 3 4 5...

Страница 19: ...P3V3_AUX ID_SW_L State Color Description On Blue System identified Off Off System not identified USB_A Vertical Type A USB Connectors Pin 1 2 3 4 Signal 5V USB D USB D GND J13 SPDIF Header Pin 1 2 3...

Страница 20: ...http www tyan com 20 J6 J4 AUX Power LED1 SATA 6G 0 1...

Страница 21: ...al GRN_BLNK_HRD KEY Pin YLW_BLNK_HRD J4 Clear CMOS Jumper 3 1 Clear CMOS 1 3 Normal Default You can reset CMOS by using this jumper if you have forgotten your system setup password or need to clear BI...

Страница 22: ...unsupported configuration Processor Installation SNB DT Socket H2 LGA1155 for Intel CPU Follow the steps below to install the processors and heat sinks Please note that the illustrations are based on...

Страница 23: ...a fully open position 4 Lift the socket cover to a fully open position 5 Place the CPU in the CPU socket and make sure that the gold arrow is located in the right direction with two notches properly a...

Страница 24: ...processor is dangerous to the motherboard For the safest method of installation and information on choosing the appropriate heat sink using heat sinks validated by Intel Please refer to the Intel webs...

Страница 25: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Страница 26: ...support studs If you are unsure of stud placement simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missin...

Страница 27: ...http www tyan com 27 Below is a chart detailing what the most common motherboard studs look like and how they should be installed...

Страница 28: ...tp www tyan com for details of the type of memory recommended for your motherboard The following diagram shows common types of DDR3 memory modules Supports un buffered non ECC DDR3 at 1066 or 1333MHz...

Страница 29: ...DIMM can offer slightly better performance than registerd DIMM if only a single DIMM per channel populated 6 We don t suggest other memory installation U DIMM Module Support DDR3 Speed Voltage DDR3 R...

Страница 30: ...http www tyan com 30 DIMM Location...

Страница 31: ...s the locking levers in the direction shown in the following illustration 2 Align the memory module with the socket The memory module is keyed to fit only one way in the socket 3 Seat the module firml...

Страница 32: ...are very simple There is no need to set Master Slave jumpers on SATA drives If you are in need of SATA SAS cables or power adapters please contact your place of purchase The following pictures illust...

Страница 33: ...ly Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card TI...

Страница 34: ...llation Onboard LAN LED Color Definition The two onboard Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different LED states 10 100 1000 Mbps LAN Link...

Страница 35: ...Main Connector Signal Pin Pin Signal 3 3V 1 13 3 3V 3 3V 2 14 12V GND 3 15 GND 5V 4 16 PS ON GND 5 17 GND 5V 6 18 GND GND 7 19 GND Power OK 8 20 Reserve 5VSB 9 21 5 12V 10 22 5 12V 11 23 5 3 3V 12 24...

Страница 36: ...roperly especially IDE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have exper...

Страница 37: ...and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program...

Страница 38: ...r best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same B...

Страница 39: ...m Language System Date System Time Access Level American Megatrends x x x x UEFI x x TYAN S5515 BIOS Vx xx MM DD YYYY xx xx xx English xxx MM DD YYYY xx xx xx Administrator Select screen Select item E...

Страница 40: ...figuration Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit ACPI Settings System ACPI Parameters S5 RTC Wake Settings En...

Страница 41: ...http www tyan com 41 Onboard Device Configuration Onboard Device Configuration...

Страница 42: ...alues F3 Optimized Defaults F4 Save Exit ESC Exit Enable ACPI Auto Configuration Enable or disable ACPI Auto Configuration Disabled Enabled Enable Hibernation Enable or disable System ability to Hiber...

Страница 43: ...Wake System with Dynamic Time Disabled Disabled Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Wake System with Fixed...

Страница 44: ...alization Technology Hardware Prefetcher Adjacent Cache Line Prefetch xx xx xx xx xx xx xx xx xx xx xx xx xx xx Enabled All Disabled Enabled Enabled Enabled Enabled Select screen Select item Enter Sel...

Страница 45: ...9 2 RedHat Enterprise 3 Update 3 Enabled Disabled Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Enabled Disable...

Страница 46: ...Port 5 Port 5 Hot Plug Enabled AHCI Empty Enabled Enabled Empty Enabled Enabled Empty Enabled Enabled Empty Enabled Enabled Empty Enabled Enabled Empty Enabled Enabled Select screen Select item Enter...

Страница 47: ...F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Legacy USB Support Enable legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE...

Страница 48: ...e power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for a Root port it is 100 ms for a Hub port the delay is taken from...

Страница 49: ...port Post Report Delay Time Summery Screen Summery Screen Enabled 5 Disabled Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC...

Страница 50: ...Configuration Aptio Setup Utility Copyright 2011 American Megatrends Inc Main Advanced Chipset Boot Security Save Exit Enable or disable Serial Port COM Serial Port 0 Configuration Serial Port Device...

Страница 51: ...s Values F3 Optimized Defaults F4 Save Exit ESC Exit Auto Fan Control Auto Fan Control Help Disabled Enabled 3 3 8 1 Sensor Data Register Monitoring Aptio Setup Utility Copyright 2011 American Megatre...

Страница 52: ...Emergency Services EMS Console Redirection Console Redirection Settings Disabled Disabled Disabled Disabled Disabled Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Valu...

Страница 53: ...Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Terminal Type Emulation ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color...

Страница 54: ...rt signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI...

Страница 55: ...S allows for remote management of a Windows Server OS through a serial port COM1 COM2 COM3 COM4 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is...

Страница 56: ...Enabled Enabled Enabled Enabled Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit EIST Enable Disable Intel SpeedStep Ena...

Страница 57: ...ROM in the Chipset Onboard Device Configuration LAN1 Option ROM LAN2 Option ROM Disabled Disabled Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Def...

Страница 58: ...t North Bridge Parameters South Bridge North Bridge WatchDog Timer Configuration Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit...

Страница 59: ...s F4 Save Exit ESC Exit DeepSx Power Policies Configure the DeepSx Mode Configuration WOL wake up function would not usable when users enable Sx function Note Mobile platforms support Deep S4 S5 in DC...

Страница 60: ...Save Exit Check to enable VT d function on MCH VT d Graphics Configuration DMI Configuration NB PCIe Configuration Memory Configuration Enabled Select screen Select item Enter Select Change Opt F1 Gen...

Страница 61: ...ect screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Initiate Graphic Adapter Select which of IGFX PEG PCI Graphics device shou...

Страница 62: ...Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Primary IGFX Boot Display Select the Video Device which will be activated during POST This has no effect if external graphics presen...

Страница 63: ...pt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit DMI Vc1 Control Enable or disable DMI Vc1 Enabled Disabled DMI Vcp Control Enable or disable DMI Vcp Enabled Disabled...

Страница 64: ...G Not present Auto Auto Auto Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit PEG0 Gen X Configure PEG0 B0 D1 F0 Gen1 Ge...

Страница 65: ...charge tRPmin Active to Precharge tRASmin XMP Profile 1 XMP Profile 2 DIMM profile Memory Frequency Limiter xx xx xx xx xx xx xx xx xx xx xx xx Default DIMM profile Auto Select screen Select item Ente...

Страница 66: ...ch Dog Mode Watch Dog Timer Disabled 2MINS Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Watch Dog Mode Watch Dog Mod...

Страница 67: ...bled UEFI Built in EFI Select screen Select item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Setup Prompt Timeout Number of seconds to wait f...

Страница 68: ...trapping by Option ROM IMMEDIATE execute the trap right away POSTPONED execute the trap during the legacy boot Immediate Postponed Endless Boot Enable or disable Endless Boot Disabled Enabled Boot Opt...

Страница 69: ...F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Launch CSM This option controls if CSM will be launched Always Auto Never Boot option filter This option controls what d...

Страница 70: ...User will have Administrator rights The password length must be in the following range Minimum length 3 Maximum length 20 Administrator Password User Password Select screen Select item Enter Select Ch...

Страница 71: ...Values F3 Optimized Defaults F4 Save Exit ESC Exit Save Changes and Exit Exit system setup after saving the changes Discard Changes and Exit Exit system setup without saving any changes Save Changes...

Страница 72: ...http www tyan com 72 NOTE...

Страница 73: ...1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard ple...

Страница 74: ...xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used Pr...

Страница 75: ...ory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initialization South Bridge module sp...

Страница 76: ...emory initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 Un...

Страница 77: ...twice installPEIMemory routine in PEI Core called twice 2 Recovery started 3 DXEIPL was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not avai...

Страница 78: ...h Bridge DXE initialization South Bridge module specific 0x77 South Bridge DXE initialization South Bridge module specific 0x78 ACPI module initialization 0x79 CSM initialization 0x7A 0x7F Reserved fo...

Страница 79: ...B5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization codes DXE Error Codes 0xD0 CPU init...

Страница 80: ...tion 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state...

Страница 81: ...Sensors This section aims to help readers identify the locations of some specific FAN and Temp Sensors on the motherboard A table of BIOS Temp sensor name explanation is also included for readers refe...

Страница 82: ...DTS Temp CPU below Tmax CPU MOS Area PCI E Ambient PCH Area DIMM Ambient CPU_Fan Front_Fan Rear_Fan VCORE VBAT 3 3V 5V 12V xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx Select screen Select item Enter...

Страница 83: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Страница 84: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Страница 85: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Страница 86: ...ster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data transf...

Страница 87: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronous...

Страница 88: ...ard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC c...

Страница 89: ...rehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system component...

Страница 90: ...d by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and t...

Отзывы: