http://www.tyan.com
159
Appendix III: FRU Parts Table
GT86C-B5630 FRU Parts
Item
Model Number
Part Number
Picture
Description
CABLES
FRU-CS-0190
422T51400001
TF-CABLE ASSY;SAS INTERNAL,SBU,
30 AWG,450 mm,MINI-SAS HD CABLE, SHORT MINI-SAS
HD 36P/SHORT MINI-SAS 36P,GT62B-B7076
FRU-CS-0560
422T56100002
TF-CABLE ASSY;SAS INTERNAL,SBU,30 AWG,600
mm,MINI-SAS HD CABLE, SHORT MINI-SAS HD
36P/SHORT MINI-SAS 36P,TN70B-B7086
FRU-CS-0870
422T56100001
TF-CABLE ASSY;SAS INTERNAL,SBU,30 AWG,700
mm,MINI-SAS HD CABLE, SHORT MINI-SAS HD
36P/SHORT MINI-SAS 36P,TN70B-B7086
FRU-CS-0210
422T51900001
TF-CABLE ASSY;SATA INTERNAL,SBU,30 AWG,700
mm,SATA CABLE (SAS WIRE),SATA 7P,180°/SATA
7P,180°,GT56-B7066
FRU-CS-0330
332810000514
TF-POWER CORD;SBU,US,125 V,16
AWG(1.31mm²),1800mm,AC PWR CORD
CCBL-0300
332810000281
TF-PWR CORD;SBU,EU,250 V,H05VV-FX3C,10A,0.75MM
HDD BP FRU-BP-9050
5412T5790003
TF-PWA;SBU,GT86A-B7051,M7051G86-BP6-4,R01,For
BB,TYAN
Power
Supply
FRU-PS-0070
471100000179
TF-POWER SUPPLY;SBU,500
W,ZIPPY,B00M1R250G008,M1R2-5500G0H,1U,1+1
REDUNDANT
FRU-PS-0072
471100000243
TF-POWER SUPPLY;SBU,500 W,DELTA,DPS-500AB-5
C,(00F),1U MODULE,REV.00F
FAN
FRU-TS-0120
336210000047
TF-FAN;SBU,FAN,12V,V40S12BGD5-07T091,2BALL,1 A,12
W,22000 RPM,27.8 CFM,3.49 inch-H2O,60.5dBA,60
g,40*40*28mm,4PIN (HEADER 1*4), WIRE=120 MM
CPU Heat
sink
FRU-TH-0200 343T55800003
HF-HEATSINK;SBU,AL/CU,SOLPIPE,3647-1U-N
ARROW-PASSIVE
HEATSINK,1A0-D032800962,108X78X25.5MM,SCREW,TN
76-B7102
Содержание B5630G86CV12
Страница 1: ...http www tyan com 1 GT86C B5630 Service Engineer s Manual...
Страница 25: ...http www tyan com 25 1 3 5 Internal View...
Страница 30: ...http www tyan com 30 2 Push the cover in the direction of the arrow and take out the top cover from chassis kit...
Страница 42: ...http www tyan com 42 4 Reinstall the riser bracket to the chassis...
Страница 46: ...http www tyan com 46 2 Secure the chassis to the rack by rotate the thumb screws...
Страница 69: ...http www tyan com 69...
Страница 95: ...http www tyan com 95 4 4 1 3 PCH sSATA Configuration...
Страница 101: ...http www tyan com 101 4 4 3 Server ME Configuration Read only...
Страница 107: ...http www tyan com 107 4 5 3 1 Memory Topology Read only...
Страница 121: ...http www tyan com 121 4 5 5 3 Intel VMD Technology...
Страница 132: ...http www tyan com 132 4 6 2 BMC Network Configuration...
Страница 141: ...http www tyan com 141 4 8 1 Network Device BBS Priorities Boot Option 1 Set the system boot order Device Name Disabled...
Страница 155: ...http www tyan com 155 5 Insert the IO Plate to the OCP card LAN port 6 Screw the IO Plate to the chassis...
Страница 156: ...http www tyan com 156 7 Insert the LAN card into the OCP slot 8 Secure the LAN card to the chassis...
Страница 160: ...http www tyan com 160 NOTE...