background image

 
The information contained in this document is subject to change 
without notice. TX Digicast makes no warranty of any kind with respect 
to this information. TX Digicast specifically disclaims the implied 
warranty of merchantability and fitness for a particular purpose. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
TX Digicast 
Clay Pit Lane 
Bar Lane Industrial Estate 
Roecliffe 
York 
United Kingdom 
YO51 9FS 
 
Telephone 01423 313550 
Telephone (International) +44 1423 313550 
 
Enquiries: [email protected] 

Содержание TXAMP200

Страница 1: ...fields cannot exceed safe limits The permitted limits vary from country to country Expert advice should be sought about the safe installation of this transmission system RISK OF FIRE RF Radio Frequenc...

Страница 2: ...rotected against antenna load faults MIS OPERATION MAY RESULT IN DAMAGE NOT COVERED BY ANY WARRANTY IMPORTANT Correct operation of the cooling fans in this product is vital to reliable continuous oper...

Страница 3: ...amplifiers are used by broadcasters worldwide and benefit from 25 years of engineers design experience The TXAMP200 uses the latest MOSFET devices achieving new levels of efficiency and reliability T...

Страница 4: ...Installation must adhere to safety regulations and the requirements of the relevant authorities We recommend that at least two people are present during installation Keep a file containing installati...

Страница 5: ...Precautions should be taken so that the grounding or polarisation of this appliance is not defeated The unit should be cleaned only as recommended by the manufacturer The RF amplifier should be servic...

Страница 6: ...r measuring compliance 4 PSU DC OK This LED indicates that the Power Amplifier Supply 48V DC is working 5 PSU AC OK This LED indicates that the AC mains power is connected 6 SYSTEM If this LED is gree...

Страница 7: ...gulations 13 REMOTE This 9 way D sub socket can be used for remote control and monitoring of the RF amplifier It also enables automatic switching of N 1 back up system configurations Pin 1 This output...

Страница 8: ...output setting press and hold the OK key for 3 seconds The TXAMP200 will enter LOCAL mode and the FWD Power level will be highlighted Press the UP or DOWN buttons to select the desired output power t...

Страница 9: ...e clearance and cooling airflow Use front to back rack supports on both sides of the RF amplifier and slide the unit into the rack NEVER ALLOW THE FRONT PANEL FIXINGS TO TAKE THE WEIGHT OF THE UNIT Fi...

Страница 10: ...is designed for continuous reliable transmission however the fans air vents and air tunnels must be periodically checked for correct operation and free airflow The cooling fans should be replaced aft...

Страница 11: ...ddress in the address bar of an internet browser IMPORTANT Accessing the RF amplifier s front panel menu will enter the TXAMP200 into local mode where front panel settings take precedence over the eth...

Страница 12: ...can be ignored because hardware devices don t usually serve https secure pages to clients However general network security is VERY IMPORTANT It is up to the user to ensure adequate overall security f...

Страница 13: ...es RF Monitoring RF monitor front panel BNC 50 ohm approx 40dB Remote I O I O Control 9 way D sub female Network LAN TCP IP RJ45 Power Supply Voltage 100 240Vac 50 60Hz Consumption Mechanical Dimensio...

Страница 14: ...nts of Directive 2014 53 EU and is CE marked accordingly Low Voltage Directive EN60215 Safety Requirements for Radio Transmitting Equipment ERM EMC ETSI EN 302 077 V2 2 0 Transmitting equipment for th...

Страница 15: ...contact your local or regional waste administration IMPORTANT NO REPRESENTATIONS OR WARRANTIES EITHER EXPRESS OR IMPLIED OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE...

Страница 16: ...respect to this information TX Digicast specifically disclaims the implied warranty of merchantability and fitness for a particular purpose TX Digicast Clay Pit Lane Bar Lane Industrial Estate Roecli...

Отзывы: