background image

- 2 - 

SAFEFY INSTRUCTION 

This chapter contains important safety instructions that you must follow when operating the AC 
power supply and when keeping it in storage. Read the following before any operation to insure 
your safety and to keep the best condition for the instrument. 
 

Safety Symbols 

The following safety symbols may appear in this manual or on the instrument: 

 

WARNING 

Identifies conditions or practices that could result in injury or loss of 
life. 

 

CAUTION 

Identifies conditions or practices that could result in damage to the 
instrument or to other properties. 

 

DANGER 

High voltage 

 

ATTENTION 

Refer to the manual 

 

 

Protective conductor terminal 

 

 

Earth (ground) terminal 

 
 
Safety Guidelines 

 

CAUTION

 

 

Before  plugging into local AC mains,  check and make sure that the 
output voltage is compatible to the load. (It is suggested to disconnect a 
load before plugging into local AC mains. 

 

Do not use this instrument near water. 

 

Do not operate or touch this instrument with wet hands. 

 

Do not open the casing of the instrument  when it is connected to AC 
mains. 

 

Avoid touch the metal contact part of the output terminals. 

 

Do not use the instrument in an atmosphere which contains sulfuric acid 
mist or other substances which cause corrosion to metal. 

 

Do not use the instrument in a dusty place or a highly humid place as 
such will cause instrument reliability degradation and instrument 
failures. 

 

Install the instrument in a place where is free from vibration. 

 

Install the instrument in a place where the ambient temperature is in 
range of -20~60

. Note that the instrument operation may become 

unstable if it is operated in an ambient temperature exceeding the range 
of 0~40

 

Power supply 

WARNING

 

AC Input voltage: 220V (single phase) /380V (three phase) ±10%, 50/60Hz 
Connect the protective grounding conductor of the AC power cord to an 
earth ground to avoid electrical shock. 

Fuse 

WARNING

 

 

Make sure the correct type of fuse is installed before power up. 

 

Replace the AC fuse with the same type and rating as the original fuse. 

 

Disconnect the power cord before fuse replacement. 

 

Make sure the cause of fuse blowout is fixed before fuse replacement. 

Содержание 6000

Страница 1: ...AC Power Supply TFC6000 Series Operation Manual V2 0 ...

Страница 2: ...tion 10 3 2 Rear Panel Description 10 3 3 Operation Instructions 12 3 3 1 Power On 12 3 3 2 Voltage Setup 12 3 3 3 Frequency Setup 12 3 3 4 High and Low Voltage Switch 12 3 3 5 Current Limit Setup 13 3 3 6 P PF Operation Key 13 3 3 7 OUTPUT RESET Key 13 3 3 8 Memory Key 13 3 3 9 System Parameter Setup 13 3 3 10 Output 14 3 4 Protections 14 3 5 Remote Control 14 4 FAULTS AND TROUBLE SHOOTING 18 5 M...

Страница 3: ...d strict quality check We warrant our instrument s mainframe and accessories in materials within the warranty period of one year We guarantee the free replacement or repair of products which are approved defective To get repair service please contact with your nearest sales and service office We do not provide any other warranty items except the one being provided by this summary and the warranty ...

Страница 4: ...h wet hands Do not open the casing of the instrument when it is connected to AC mains Avoid touch the metal contact part of the output terminals Do not use the instrument in an atmosphere which contains sulfuric acid mist or other substances which cause corrosion to metal Do not use the instrument in a dusty place or a highly humid place as such will cause instrument reliability degradation and in...

Страница 5: ...e AC or 380V 10 50Hz 10 three phase AC Please use a proper input power before turn on the AC power supply and use a fuse with same specification of the original The fuse specification is indicated on the rear panel of the power supply WARNING Disconnect the power cord before fuse replacement WARNING Always keep good connection of the grounding wire and make sure to connect the grounding wire to th...

Страница 6: ... and pack the power supply if it must be sent back to us for repairing And contact our service center before returning All the accessories included with the power supply must be returned along with the power supply and demonstrate the damage or malfunction In addition please mark the package with a label indicating FRAGILE AND HANDLE WITH CARE Other Packing If the original packing materials are no...

Страница 7: ... active power frequency and power factor Regulator response time less than 2ms for 100 load and unload Great overload capability instantaneous current can withstand 3 times of the rated current Software startup good for inductive load such as motor start transformer Protection Over voltage over current over load short circuit and current limit protections Interface RS232 optional for remote PC con...

Страница 8: ...25A 168A H 240V 2 1A 4 2A 12 5A 21A 42A 62 5A 84A Load regulation 1 T H D 2 Low range 120V high range 204V pure resistive load Frequency regulation 0 01 LED display Vrms Arms Fre Wattage PF Voltage resolution 0 1V Frequency resolution 0 1Hz Current resolution 0 001A 0 01A 0 1A Memory M1 V_F_A M2 V_F_A M3 V_F_A Interface RS232C optional Current limit setup O Max Current Protection Over Current Over...

Страница 9: ...A 420A 625A Load regulation 1 T H D 2 Low range 120V high range 204V pure resistive load Frequency regulation 0 01 LED display Vrms Arms Fre Wattage PF Voltage resolution 0 1V Frequency resolution 0 1Hz Current resolution 0 1A 1A Memory M1 V_F_A M2 V_F_A 3 V_F_A Interface RS232C optional Current limit setup O Max Current Protection Over Current Over Temperature Over Load and Short Circuit protecti...

Страница 10: ... 42A 56A H 240V 8 4A 12 5A 17A 21A 28A Load regulation 1 T H D 2 Low range 120V high range 204V pure resistive load Frequency regulation 0 01 LED display Vrms Arms Fre Wattage PF Voltage resolution 0 1V Frequency resolution 0 1Hz Current resolution 0 01A Memory M1 V_F_A M2 V_F_A M3 V_F_A Interface RS232C optional Current limit setup O Max Current Protection Over Current Over Temperature Over Load ...

Страница 11: ... 1 T H D 2 Low range 120V high range 204V pure resistive load Frequency regulation 0 01 LED display Vrms Arms Fre Wattage PF Voltage resolution 0 1V Frequency resolution 0 1Hz Current resolution 0 01A 0 1A 1A Memory M1 V_F_A M2 V_F_A M3 V_F_A Interface RS232C optional Current limit setup O Max Current Protection Over Current Over Temperature Over Load and Short Circuit protections Weight Kg 300 50...

Страница 12: ...RMS value 4 Power power factor meter 5 Input switch 6 RS232 interface for PC control 7 Output socket 8 Operating keys 3 2 Rear Panel Description Wiring description for 1 Phase AC power supply 1 Output connector bar L live wire N null wire G grounding wire 2 Input connector bar L live wire N null wire G grounding wire ...

Страница 13: ... 450KVA 1 Non fuse output switch 2 Non fuse input switch 3 Output connector bar U U phase V V phase W W phase N null wire PE protective earth wire 4 Input connector bar L1 L1phase L2 L2phase L3 L3phase N null wire PE protective earth wire 5 G grounding wire ...

Страница 14: ...rom the decimal digit Keep holding the key or the voltage value will increase or decrease step by step in very duration of 0 3 second Each step is 0 1V After the decimal digit reaches full value it will automatically go to the next digit at same step When it goes to the hundreds digit the step speed is 1 step in every 0 1 second If the voltage setup has no operation within 2 seconds the voltmeter ...

Страница 15: ...3 7 OUTPUT RESET Key The OUTPUT RESET key can turn on or off the output The OUTPUT RESET LED indicator lights on when the output is ON When there is abnormal output the output will be automatically turned off and the OUTPUT RESET LED indicator will blink The beeper alarms at the same time Press this button once to turn off the beeper Press it twice to reset the output Press it for the third time t...

Страница 16: ... this situation first turn off the output by pressing the POWER switch Next check and clarify reasons of alarming For example if there is over load reduce load capacity and reset The power supply will return to normal operation mode In case of over load or short circuit do not press RESET key right after the alarm to reset the settings because this operation will have impact in the power supply ma...

Страница 17: ...set Operation code Refer to section 3 Action object Data Low byte in the front high byte in the end Write command data written into AC power supply Read command send back data to PC Reset command ignored Check code The add up of the first 7 bytes NOTE After receiving the software RESET code the AC power supply will not send back any response code 3 6 2 Data format from AC power supply to PC Equipm...

Страница 18: ...h range 0x33 Desired voltage in auto range The voltage value format is 4 bytes unit 0 1V range 0 3000 The current voltage value The refreshed voltage value According to the current voltage value it will automatically switch between high range and low range If the voltage value is set at 1500 or above it switches to high range Otherwise it switches to low range 0x34 Maximum output current The maxim...

Страница 19: ...at 120V Successful response 01 57 33 B0 04 00 00 3F 01 57 33 B0 04 00 00 3F 2 Set auto range voltage at 240V Successful response 01 57 33 60 09 00 00 F4 01 57 33 60 09 00 00 F4 3 Set high range voltage at 120V Successful response 01 57 32 B0 04 00 00 3E 01 57 32 B0 04 00 00 3E 4 Set high range voltage at 240V Successful response 01 57 32 60 09 00 00 F3 01 57 32 60 09 00 00 F3 5 Set frequency at 60...

Страница 20: ...y Fault Remote control port failure Causes a The remote control address baud rate are different from the settings on the PC b Connector or wire problem In this case disconnect the instrument from the PC c L loose contact or jamming Clear a Make the remote control address and baud rate the same on the PC and the instrument b Test the signal wire between the instrument and the PC The TXD to GND term...

Страница 21: ...ning disconnect the AC mains To clean the power supply use a soft cloth dampened in a solution of mild detergent and water Do not spray cleaner directly onto the power supply since it may leak into the cabinet and cause damage Do not use chemicals containing benzene benzene toluene xylene acetone or similar solvents Do not use abrasive cleaners on any portion of the power supply 5 3 Modification N...

Отзывы: