MODELS  T100  T150

T200  T250  T300

!

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If

you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel

and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a quali-

fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage elec-

trical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.

9. Never place a switch where it can be reached from a tub or

shower.

10. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

3. Please read specification label on product for further informa-

tion and requirements.

CEILING / WALL-MOUNT
VENTILATORS  120V

READ AND SAVE THESE INSTRUCTIONS

TABLE OF CONTENTS

This manual is divided into sections as follows:

 “TYPICAL INSTALLATION”

This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (horizontal blower discharge)

 “MOUNTING OPTIONS”

 “WIRING OPTIONS”

-Wiring Plate Position

 “DUCTING OPTIONS”

- Blower Discharge Positions
- Ducting (vertical blower discharge)

 “USE AND CARE”

 “SERVICE PARTS”

 “WARRANTY”

Installer: Leave this manual with
the homeowner.

Homeowner: Use and Care
information on page 3.

Содержание T100

Страница 1: ...en cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Neve...

Страница 2: ...ite sides of housing upside down so housing is flush with finished ceiling DUCTING Horizontal blower discharge ROOF CAP ROUND ELBOW ROUND DUCT WALL CAP IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight Remove shipping ring...

Страница 3: ...ing nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Ventilator is designed for continuous operation If desire...

Страница 4: ...eller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defects should reasonably have been discovered whichever is l...

Отзывы: