Chapter 4 Flow measurement
- 28 -
4.1.2. Steady Flow
The steady flow of the fluid contributes to the stability of the measurement, thus
ensuring the accuracy of the measurement.And the flow state is chaotic flow
To make the measured data unstable or unmeasurable.
To meet the standard requirements of steady flow conditions:
1. When the pipeline is far away from the pump outlet and the valve is partially
opened, the straight pipe section shall be 10D upstream and 5D downstream (D is
the outer pipe diameter).
2. 30D from the pump outlet and the straight pipe section of the semi-open valve.
Full pipe
Possible dissatisfaction
with management
A vertical upward flow pipe
A verticall downward flow pipe
An upward sloping pipe
An downward sloping pie
The lowest point in a piping system
The highest point in a piping system
Natural flow
No pressure in the pipe