CitySense Plus
Installation Manual
Cable Gland
English
Страница 1: ...CitySense Plus Installation Manual Cable Gland English ...
Страница 2: ...or Date Changes Approved by v4 Henri Eskonen 21 12 2017 Added version control page Minor formatting v4 21 12 2017 TVILIGHT BV Westerhaven 13 9718 AW Groningen the Netherlands 31 0 50 800 3240 info tvilight com www tvilight com ...
Страница 3: ...erly CitySense Plus must be connected to a dimmable driver ballast NOTE Some dimmable drivers ballasts must be programmed set to dimmable mode If this has not been done CitySense Plus will not be able to dim the connected armature ATTENTION ...
Страница 4: ...Page 4 of 10 In box 5m Cable M16 Cable Gland Sticker Generic Strap x 2 You ll need Max 11mm Min 8mm M16 Thread Drill Wago x 4 TVILIGHT www tvilight com TVI CSP1 01 0014 ...
Страница 5: ... of 10 1 Push cable gland through wire 2 Drill M16 threaded hole into pole 5m Note for added protection against rust the use of an anti corrosion spray such as WD40 Corrosion inhibitor or equal is recommended ...
Страница 6: ...Page 6 of 10 3 Run wire through hole 4 Screw cable gland in hole Rotate the cable gland to tighten Twist the end leads of the wires ...
Страница 7: ...Page 7 of 10 5 Strap product to pole 6 Level the product Ensure Tensioning Tool is set to maximum tension 4 Tensioning Tool Position 2 Standard 1 2 3 ...
Страница 8: ...Page 8 of 10 SAME TVILIGHT www tvilight com TVI CSP1 01 0014 TVILIGHT www tvilight com TVI CSP1 01 0014 TVILIGHT www tvilight com TVI CSP1 01 0014 7 Apply product ID sticker to pole 2 m ...
Страница 9: ...ram WARNING If not correctly connected product might not function or it might be permanently damaged DC Connector e g Wago AC in N AC in L DC L N Junction Box GND GND N L L out N out DC DC GREEN BROWN WHITE BLACK GREY BLUE RED ...
Страница 10: ...LACK GREY BLUE RED N L Lout Nout 1 10V or DALI 1 10V or DALI Wiring Diagram WARNING If not correctly connected product might not function or it might be permanently damaged Note For added protection it is recommenteded to add an external circuit breaker at the power input of the product Circuit breakers such as the ELeQ LS 94 5L2408 or similar rated products could be used ...
Страница 11: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 meters Tilt 0 degrees 2 m 7 5 m 2 m 0 5 m 7 m 3 2 m 13 5 m 4 5 m ...
Страница 12: ...2 7 m 10 65 m 2 42m 4 16 m 2 25 m 3 7 m 1 1 m 2 2 m 9 4 m 14 8 m 14 m 5 3 m 4 9 m CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 meters Tilt 7 5 degrees ...
Страница 13: ...12 8 m 12 8 m 5 2 m 4 1 m 5 6 m 2 1m 5 2 m 1 m 2 42m 4 16 m 2 25 m CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 meters Tilt 7 5 degrees ...
Страница 14: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 5 meters Tilt 0 degrees 8 5 m 2 25 m 3 6 m 2 m 0 6 m 15 m 5 m 7 7 m ...
Страница 15: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 5 meters Tilt 7 5 degrees 12 1 m 3 m 4 7 m 2 7 m 2 25 m 4 1 m 1 2 m 2 5 m 10 5 m 16 7 m 15 8 m 6 m 5 5 m ...
Страница 16: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 5 meters Tilt 7 5 degrees 4 6 m 6 3 m 2 4 m 1 1 m 6 m 5 8 m 10 5 m 14 3 m 2 7 m 4 7 m 2 25 m ...
Страница 17: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 meters Tilt 0 degrees 2 5 m 9 5 m 2 5 m 4 m 16 5 m 5 5 m 0 7 m 8 5 m ...
Страница 18: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 meters Tilt 7 5 degrees 5 2 m 3 m 13 5 m 3 4 m 2 75 m 18 5 m 17 5 m 6 6 m 6 1 m 4 6 m 1 4 m 2 8 m 11 7 m ...
Страница 19: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 meters Tilt 7 5 degrees 7 m 2 6 m 1 3 m 6 5 m 15 9 m 11 8 m 6 4 m 5 1 m 5 2 m 3 m 2 45 m ...
Страница 20: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 5 meters Tilt 0 degrees 10 5 m 2 75 m 2 75 m 4 4 m 16 5 m 5 5 m 0 7 m 9 3 m ...
Страница 21: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 5 meters Tilt 7 5 degrees 2 75 m 5 7 m 14 9 m 3 7 m 3 4 m 20 m 19 3 m 7 3 m 6 7 m 5 m 1 5 m 3 m 12 8 m ...
Страница 22: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 5 meters Tilt 7 5 degrees 7 7 m 2 9 m 1 4 m 7 1 m 17 5 m 13 m 7 1 m 5 6 m 2 72 m 5 7 m 3 4 m ...