6
MODEL
SDV-120
SDV-200
SDV-320
SDV-430
SDV-800
SDV-1500
SDV-2700
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
Nominal
Displacement
Capacity
CFM
m³/hr
59
100
71
120
88
150
106
180
157
267
188
320
211
358
253
430
368
625
441
750
765
1300
882
1500
1324
2250
1588
2700
Ultimate Pressure
Torr
0.04
0.02
0.04
0.02
0.03
0.01
0.03
0.01
0.03
0.01
0.2
0.1
0.2
0.1
Motor
HP
kW
5
3
5
3.7
10
7.5
15
11
20
15
50
37
75
55
Power
Connection
Type
C-Flange
C-Flange
C-Flange
C-Flange
C-Flange
Bare Shaft
Bare Shaft
Speed
RPM
2900
3500
2900
3500
2900
3500
2900
3500
2900
3500
1450
1750
1450
1750
Port Size (inches)
150 # FF
Inlet
Outlet
1.5
1.5
1.5
1.5
2
1.5
2.5
2
4
2.5
5
3
6
4
Gear Oil
Gallon
(1)
Liter
0.13
0.5
0.26
1
0.48
1.8
0.48
1.8
0.58
2.2
1.85
7
2.38
9
Grease
Ounces
Grams
1
30
1
30
3.5
100
3.5
100
3.9
110
6
170
8.8
250
Cooling water
@ 20
o
C (68
o
F)
(2)
GPM
L/min
0.5
2
1
4
2.1
8
2.9
11
5.3
20
7.4
28
9.5
36
Cooling Purge
SCFM
(3)
Sm³/hr
NONE
NONE
NONE
NONE
29.4
50
94.1
160
100
170
Discharge Temp
°F
°C
<230
110
<248
120
<311
155
<347
175
<455
235
<482
250
<500
260
Inlet Gas
°F
°C
122
50
122
50
122
50
122
50
122
50
122
50
122
50
Discharge Gas
°F
°C
392
200
392
200
482
250
482
250
572
300
572
300
572
300
Oil
°F
°C
158
70
158
70
158
70
158
70
158
70
158
70
158
70
Grease
°F
°C
176
80
176
80
176
80
176
80
176
80
176
80
176
80
Noise
dBA
(4)
72
72
80
80
85
85
90
Weight
lbs
kg
396
180
484
220
616
280
770
350
1212
550
2310
1050
2970
1350
Dimmensions,
L x W x H
(5)
Inches
mm
19 × 13.1 × 10.3
483 × 332 × 262
29.9 × 14.9 × 11.6
760 × 378 × 294
33.8 × 17.1 × 12.8
858 × 434 × 326
39.1 × 19.4 × 13.9
993 × 492 × 352
44.5 × 20.4 × 15.3
1131 × 519 × 389
53.9 × 27.4 × 21.2
1368 × 695 × 539
60.6 × 33.1 × 23
1539 × 842 × 585
(1) Above listed amount of oil is for reference only. Oil should be filled to the top level of Red Mark or NL Mark. Please note that special inert oils are available for
hazardous applications.
(2) Above listed amount of Cooling Water is based on water temperature of 20°C (68°F). The amount of water varies when using an After Cooler. Temperature differential
between Cooling Water supply temperature and discharge temperature shall be maintained below 7°C (12.6°F).
(3) Cooling Purge flow rate shown above are at standard conditions.
(4) Noise level shown above are based on the pump equipped with exhaust silencer and are from 1 meter (3 feet) away from the pump.
(5) dimensions shown above are for bareshaft pump only (without motor).
SPECIFICATIONS TABLE
Содержание KINNEY SDV SDV-120
Страница 28: ...28 NEW SDV 320 EXPLODED VIEW DRAWING NOTES ...