Installation Guide
Please read this installation manual carefully, it contains
important information and notes regarding the installation and
operation of VIVID T8 LED ByPass Tube (BPSP4).
Non-Shunted Lamp Holder
Order
Code
Model
Number
24”
24”
24”
24”
36”
36”
36”
36”
48”
48”
48”
48”
48”
48”
48”
48”
Discription
Volts
VIV-T8BPSP4/9W/30/F
VIV-T8BPSP4/9W/35/F
VIV-T8BPSP4/9W/40/F
VIV-T8BPSP4/9W/50/F
VIV-T8BPSP4/12W/30/F
VIV-T8BPSP4/12W/35/F
VIV-T8BPSP4/12W/40/F
VIV-T8BPSP4/12W/50/F
VIV-T8BPSP4/12.5W/30/F
VIV-T8BPSP4/12.5W/35/F
VIV-T8BPSP4/12.5W/40/F
VIV-T8BPSP4/12.5W/50/F
VIV-T8BPSP4/14.5W/30/F
VIV-T8BPSP4/14.5W/35/F
VIV-T8BPSP4/14.5W/40/F
VIV-T8BPSP4/14.5W/50/F
T8 Bypass 2ft 9W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 50K Frost Shatterproof DLC4.0
T8 Bypass 3ft 12W G13 30K Frost Shatterproof
T8 Bypass 3ft 12W G13 35K Frost Shatterproof
T8 Bypass 3ft 12W G13 40K Frost Shatterproof
T8 Bypass 3ft 12W G13 50K Frost Shatterproof
T8 Bypass 4ft 12.5W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 50K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 50K Frost Shatterproof DLC4.0
Tube
Size
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
1762771
1762356
1762853
1762534
1762296
1762311
1762484
1762514
1762746
1762342
1762833
1762527
1763231
1763313
1763432
1763512
Applicable to the following models
VIVID™ T8 LED ByPass Shatterproof 4 Tube (BPSP4)
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT
LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED
BY CSA OR AUTHORITIES HAVING JURISDICTION.
WARNING
•
Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires
electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
•
Risk of fire or electric shock. Install this kit only in the luminaires that have the
construction features and dimensions show in the photographs and/or drawings.
•
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or
other sharp objects.
CAUTION
•
Disconnect power at the source before installation. Do not simply switch off fixture.
•
This item is rated at 120-277V. Installer must determine whether they have 120-277V at
the luminaire before installation.
•
This device is not intended for use with emergency exits.
•
Do not use with luminaire ballast.
•
Do not use with dimmers.
•
Do not use if product is damaged.
•
Use with supplied non-shunted lamp holders only.
•
Connect hot wire only to end cap with the Turolight logo driver side.
Opposite end cap
requires no wiring.
•
To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing
shunted bi-pin lamp holders.
Note:
Non-Shunted Lamp Holder Supplied with LED T8 Luminaire. Shunted lamp
holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant -start
ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This
designation may be in the form of a statement pertaining to the ballast itself, or may be
combined with the marking for the lamps with which the ballast is intended to be used.
For more information, contact the Turolight representative.
•
“This luminaire has been modified and can no longer operate the originally intended
lamp,” shall be marked on the retrofit luminaire where readily visible by the user during
normal maintenance including relamping (sticker supplied).
•
Risk of fire or electric shock. Do not modify the circuitry or any electrical components of tube.
•
Installers should not disconnect existing wires from lampholder terminals to make new
connections at lampholder terminals. Instead installers should cut existing lampholder
leads away from the lampholder and make new electrical connections to lampholder
lead wires by employing applicable connectors.
•
Suitable for damp location.
•
Suitable for “Type IC” or “Type Non-IC” luminaires. No external weight or mechanical force
on tube or components.
•
Beware of electric shock when installing tube.
•
Dispose of fluorescent lamps and ballst according to local/provincal/federal regulations.
•
Contact your local Turolight Distributor if you have any questions about the installation of this lamp.
L~
Driver
N~
Hot Connecting End
L~
Driver
N~
TO ORDER PLEASE CALL
1-877-736-0447
OR EMAIL:
Tel: (416) 736-0447 • Toll Free: 1 (877) 736-0447 • Fax: (416) 736-4890 • Email: [email protected] • Website: www.turolight.com