background image

Installation Guide

Please read this installation manual carefully, it contains 
important information and notes regarding the installation and 
operation of VIVID T8 LED ByPass Tube (BPSP4).

Non-Shunted Lamp Holder

Order

Code

Model

Number

24”
24”
24”
24”
36”
36”
36”
36”
48”
48”
48”
48”
48”
48”
48”
48”

Discription

Volts

VIV-T8BPSP4/9W/30/F
VIV-T8BPSP4/9W/35/F
VIV-T8BPSP4/9W/40/F
VIV-T8BPSP4/9W/50/F
VIV-T8BPSP4/12W/30/F
VIV-T8BPSP4/12W/35/F
VIV-T8BPSP4/12W/40/F
VIV-T8BPSP4/12W/50/F
VIV-T8BPSP4/12.5W/30/F
VIV-T8BPSP4/12.5W/35/F
VIV-T8BPSP4/12.5W/40/F
VIV-T8BPSP4/12.5W/50/F
VIV-T8BPSP4/14.5W/30/F
VIV-T8BPSP4/14.5W/35/F
VIV-T8BPSP4/14.5W/40/F
VIV-T8BPSP4/14.5W/50/F

T8 Bypass 2ft 9W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 50K Frost Shatterproof DLC4.0
T8 Bypass 3ft 12W G13 30K Frost Shatterproof
T8 Bypass 3ft 12W G13 35K Frost Shatterproof
T8 Bypass 3ft 12W G13 40K Frost Shatterproof
T8 Bypass 3ft 12W G13 50K Frost Shatterproof
T8 Bypass 4ft 12.5W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 50K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 50K Frost Shatterproof DLC4.0

Tube

Size

120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277

1762771
1762356
1762853
1762534
1762296
1762311
1762484
1762514
1762746
1762342
1762833
1762527
1763231
1763313
1763432
1763512

Applicable to the following models

VIVID™ T8 LED ByPass Shatterproof 4 Tube (BPSP4)

THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT 

LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED 

BY CSA OR AUTHORITIES HAVING JURISDICTION. 

WARNING

 

Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires 
electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.

 

Risk of fire or electric shock. Install this kit only in the luminaires that have the 

construction features and dimensions show in the photographs and/or drawings.

 

To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or 

other sharp objects.

CAUTION

 

Disconnect power at the source before installation. Do not simply switch off fixture.

 

This item is rated at 120-277V. Installer must determine whether they have 120-277V at 

the luminaire before installation.

 

This device is not intended for use with emergency exits.

 

Do not use with luminaire ballast.

 

Do not use with dimmers.

 

Do not use if product is damaged.

 

Use with supplied non-shunted lamp holders only. 

 

Connect hot wire only to end cap with the Turolight logo driver side.  

Opposite end cap 

requires no wiring.

 

To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing 

shunted bi-pin lamp holders. 

Note:

  Non-Shunted  Lamp Holder Supplied with LED T8 Luminaire. Shunted lamp 

holders  are found only in fluorescent luminaires with Instant-Start ballasts. Instant -start 
ballasts  can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This 
designation may be in the form of a statement pertaining to the ballast itself, or may be 
combined with the marking for the lamps with which the ballast is intended to be used. 
For more information, contact the Turolight representative.

 

“This luminaire has been modified and can no longer operate the originally intended 

lamp,” shall be marked on the retrofit luminaire where readily visible by the user during 
normal maintenance including relamping (sticker supplied).

 

Risk of fire or electric shock. Do not modify the circuitry or any electrical components of tube.

 

Installers should not disconnect existing wires from lampholder terminals to make new 

connections at lampholder terminals. Instead installers should cut existing lampholder 
leads away from the lampholder and make new electrical connections to lampholder 
lead wires by employing applicable connectors.

 

Suitable for damp location.

 

Suitable for “Type IC” or “Type Non-IC” luminaires. No external weight or mechanical force 

on tube or components.

 

Beware of electric shock when installing tube.

 

Dispose of fluorescent lamps and ballst according to local/provincal/federal regulations.

 

Contact your local Turolight Distributor if you have any questions about the installation of this lamp.

L~

Driver 

N~

Hot Connecting End

L~

Driver 

N~

TO ORDER PLEASE CALL 

1-877-736-0447

 OR EMAIL: 

[email protected]