Electrical connection
46
5816,0013US / Version 02
Electromagnetic interference
NOTICE
Electromagnetic interferences may cause
malfunctions of the barrier or adjacent devices!
The barrier is approved for industrial, residential,
commercial and business use. Operation in other
electro-magnetic environmental conditions may
cause interferences or malfunctions.
– Place control lines and mains cables into
separate conduits
– Use cables according to the electrical circuit
plan.
– Only install and apply additional parts approved
by MAGNETIC.
– The electrical and electronically additional parts
must be EMC verified and must not exceed the
indicated EMC limits.
Personal protective equipment
The following must be worn during all installation work:
Work clothes
Protective gloves
Safety shoes.
8.2
Installing electrical protective devices
The safety installations that are required according to regional and
local regulations must be provided by the customer. Usually these
are:
Ground fault circuit interrupter (GFCI)
Circuit-breaker
Appropriate listed 2-pole main switch.
Traffic H1 Swing Gate Horizontal Barrier
www.TURNSTILES.us | [email protected] | 303-670-1099