ZERO POSITION CONFIGURATION

After all three zero positions are set, the display shows saved values. If the values are cor

-

rect, “OK” message is displayed. If the values are not correct, “Error” message is displayed. 

This means that the values of zero positions are not saved and the procedure shall be 

repeated. Regardless of the result of the configuration, after pressing the encoder, settings 

menu will be displayed.

To save changes, choose the Save & Exit option.

CALIbRATION

After choosing the calibration option in the bottom row  of the screen the rotor speed is 

shown. The controller will try to slowly move the device’s motor to identify it’s parameters.

Notice: During the calibration nothing shall interrupt the rotor’s movement. Otherwise the 

procedure has to be repeated.

This option is not available in GA and BASIC series gates.

After the calibration procedure is finished, the identified parameters are displayed. After 

pressing the encoder, controller returns to the Settings menu.

To save changes, choose the Save & Exit option.

This option is not available in GA and BASIC series gates.

FIRST RUN

In order to provide safety during first run, follow these rules:

1.  Before applying power to the device make sure that all cables are connected properly.

2.  Wrong connection of the encoder may cause the device to behave in an unpredictable way. Take extra safety precautions.

www.TURNSTILES.us

[email protected]

303-670-1099

Содержание BA3 Series

Страница 1: ...1 SG BA3 BR2 GA SERIES DEVICES CONTROL MODULE User s Manual...

Страница 2: ...2 Complete documentation GENERAL INFORMATION PEDESTRIAN TRAFFIC CONTROL DEVICE CONTROL MODULE MONTAGE MAINTENANCE AND SERVICE TECHNICAL DRAWINGS EN...

Страница 3: ...3...

Страница 4: ...PICTOGRAMS CONFIGURATION 7 LICENSE MENU 7 TEST MODE 8 SG SERIES DEVICES 8 DESCRIPTION OF THE CONTROL MODULE TERMINALS 8 SETTINGS MENU 9 ZERO POSITION CONFIGURATION 9 CALIBRATION 10 FIRST RUN 10 BA3 BR...

Страница 5: ...g software without the device manufacturer s consent The manufacturer reserves the right to introduce changes or updates to the software All devices are supplied with a stored standard software descri...

Страница 6: ...of the rotor encoder Vel current velocity of the rotor Back return to the main menu SETTINGS MENU Language configuration Choose the interface language Default setting PL Free entrance function Set the...

Страница 7: ...enu allows you to insert the license key to unlock the license Submitting an in correct key results in a temporary blockade of this menu item Pictograms configuration Pictograms configuration submenu...

Страница 8: ...ck option In devices of the BA3 BR2 and GA series the mode is used only in devices equipped in the rotor s movement support system Caution While starting the test mode no person can be found within th...

Страница 9: ...for a trigger signal If this setting is different than the central one it is recommended to use this setting in combination with the free passage in that direction Default setting cen Fire alarm conf...

Страница 10: ...e when manually moving the arm 3 Check the connection of optical sensors menu parameters A 0 digit means that the barrier is interrupted while 1 means that the barrier is not interrupted 4 The zero po...

Страница 11: ...ETTINGS MENU Coils type There are two options for each coil NOR normal coil during power failure the rotor stays blocked REV reverse coil during power failure the rotor stays unblocked Default setting...