12
EN
CONTROL
MODULE
ZERO POSITION CONFIGURATION
After all three zero positions are set, the display shows saved values. If the values are cor
-
rect, “OK” message is displayed. If the values are not correct, “Error” message is displayed.
This means that the values of zero positions are not saved and the procedure shall be
repeated. Regardless of the result of the configuration, after pressing the encoder, settings
menu will be displayed.
To save changes, choose the Save & Exit option.
CALIbRATION
After choosing the calibration option in the bottom row of the screen the rotor speed is
shown. The controller will try to slowly move the device’s motor to identify it’s parameters.
Notice: During the calibration nothing shall interrupt the rotor’s movement. Otherwise the
procedure has to be repeated.
This option is not available in GA and BASIC series gates.
After the calibration procedure is finished, the identified parameters are displayed. After
pressing the encoder, controller returns to the Settings menu.
To save changes, choose the Save & Exit option.
This option is not available in GA and BASIC series gates.
FIRST RUN
In order to provide safety during first run, follow these rules:
1. Before applying power to the device make sure that all cables are connected properly.
2. Wrong connection of the encoder may cause the device to behave in an unpredictable way. Take extra safety precautions.